Comparison of sandy soil shear strength parameters obtained by various construction direct shear apparatuses

被引:20
作者
Amsiejus, J. [1 ]
Dirgeliene, N. [1 ]
Norkus, A. [1 ]
Skuodis, S. [1 ]
机构
[1] Vilnius Gediminas Tech Univ, Fac Civil Engn, LT-10223 Vilnius, Lithuania
关键词
Direct shear test; Movable lower shear ring of sample; Constant volume; Soil shear strength parameters; Angle of internal friction; SPECIMEN SIZE; TESTS; SCALE;
D O I
10.1016/j.acme.2013.11.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An analysis of test results performed by common type of direct shear apparatuses shows that normal stress on the shear plane of soil sample is not equal to vertical component of distributed external load applied to the top of soil sample. Performed measurements cleared that only 65-85% of total vertical load is transmitted to the sample shear plane. Thus, determining of the soil shear strength depends on shear apparatus construction, i.e. on actual magnitude of vertical load transmitted to the shear plane. The paper presents an analysis of shear strength parameters of sand determined by two different construction of direct shear apparatuses with movable lower shear ring. The soil shear strength parameters by employing direct shear apparatus SPF-2 have been obtained under constant vertical load and measuring the vertical load at different positions, namely: at the bottom and that of at the top of soil sample, respectively. The soil strength parameters by employing the universal shear testing device ADS 1/3 were determined under two conditions, namely: by maintaining constant soil volume and that of for constant vertical load, respectively. In both cases the vertical load was measured at the top of soil sample. (C) 2013 Politechnika Wroclawska. Published by Elsevier Urban & Partner Sp. z 0.0. All rights reserved.
引用
收藏
页码:327 / 334
页数:8
相关论文
共 22 条
  • [1] Alikonis A., 1999, SOIL MECH GEOT ENG 1, P1053
  • [2] Amsiejus J., 2000, THESIS VILNIUS GEDIM, P141
  • [3] Amsiejus J, 2007, BALT J ROAD BRIDGE E, V2, P125
  • [4] EVALUATION OF SOIL SHEAR STRENGTH PARAMETERS VIA TRIAXIAL TESTING BY HEIGHT VERSUS DIAMETER RATIO OF SAMPLE
    Amsiejus, Jonas
    Dirgeliene, Neringa
    Norkus, Arnoldas
    Zilioniene, Daiva
    [J]. BALTIC JOURNAL OF ROAD AND BRIDGE ENGINEERING, 2009, 4 (02): : 54 - 60
  • [5] [Anonymous], 2004, EUROCODE 7 GEOTECH 1, P168
  • [6] [Anonymous], 2006, GEOTECH TEST J
  • [7] Comparison of shear strength of sand backfills measured in small-scale and large-scale direct shear tests
    Bareither, Christopher A.
    Benson, Craig H.
    Edil, Tuncer B.
    [J]. CANADIAN GEOTECHNICAL JOURNAL, 2008, 45 (09) : 1224 - 1236
  • [8] NUMERICAL-ANALYSIS OF DRAINED DIRECT AND SIMPLE SHEAR TESTS
    DOUNIAS, GT
    POTTS, DM
    [J]. JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1993, 119 (12): : 1870 - 1891
  • [9] Modified direct shear test for anisotropic strength of sand
    Guo, Peijun
    [J]. JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2008, 134 (09) : 1311 - 1318
  • [10] Heng S., 2010, P 17 SE AS GEOT C MA, P83