Null test compensators for ophthalmic lenses

被引:2
|
作者
Trujillo-Schiaffino, G [1 ]
Malacara-Hernández, D [1 ]
机构
[1] AC, Ctr Invest Opt, Leon 37000, Gto, Mexico
关键词
lenses; optical testing; refractive index;
D O I
10.1117/1.1512304
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Testing methods commonly used for ophthalmic lenses produce a power distribution map that treats the lens as an independent element. This map, however, does not necessarily correspond to the refractive correction state of the lens when the observer looks through it. We describe a method to obtain a refractive correction map of an ophthalmic lens, which is an improved representation of its actual performance. (C) 2002 Society of Photo-Optical instrumentation Engineers.
引用
收藏
页码:2910 / 2914
页数:5
相关论文
共 50 条
  • [1] Computer based null test compensation for ophthalmic lenses
    Trujillo-Schlaffino, G
    Salas-Peimbert, DP
    Malacara-Hernández, D
    Malacara-Doblado, D
    Almazán-Cuéllar, S
    RIAO/OPTILAS 2004: 5TH IBEROAMERICAN MEETING ON OPTICS AND 8TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND THEIR APPLICATIONS, PTS 1-3: ICO REGIONAL MEETING, 2004, 5622 : 97 - 101
  • [2] Ophthalmic lenses measurement using Hartmann test
    Salas-Peimbert, DP
    Trujillo-Schiaffino, G
    Malacara-Hernández, D
    Malacara-Doblado, D
    Almazán-Cuéllar, S
    RIAO/OPTILAS 2004: 5TH IBEROAMERICAN MEETING ON OPTICS AND 8TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND THEIR APPLICATIONS, PTS 1-3: ICO REGIONAL MEETING, 2004, 5622 : 102 - 106
  • [3] HARTMANN TEST MODIFICATION FOR MEASURING OPHTHALMIC PROGRESSIVE LENSES
    CASTELLINI, C
    FRANCINI, F
    TIRIBILLI, B
    APPLIED OPTICS, 1994, 33 (19): : 4120 - 4124
  • [4] EVALUATION OF OPHTHALMIC SPECTACLE LENSES USING THE HARTMANN TEST
    STATTON, CM
    BAUER, MD
    MEYERARENDT, JR
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1981, 58 (09): : 766 - 771
  • [5] Simple Hartmann test data interpretation for ophthalmic lenses
    Salas-Peimbert, DP
    Trujillo-Schiaffino, G
    González-Silva, JA
    Almazán-Cuellar, S
    Malacara-Doblado, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (04):
  • [6] Null screens type Hartmann to test simple lenses
    Castillo-Santiago, Gabriel
    Castan-Ricano, Diana
    Gonzalez-Galindo, Alfredo
    Avendano-Alejo, Maximino
    Diaz-Uribe, Rufino
    OPTICAL MANUFACTURING AND TESTING XI, 2015, 9575
  • [7] IMPACT ON OPHTHALMIC LENSES
    GOLDSMITH, W
    TAYLOR, RL
    EXPERIMENTAL MECHANICS, 1976, 16 (03) : 81 - 87
  • [8] Sagitta of ophthalmic lenses
    Faria-e-Sousa, Sidney Julio
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2020, 40 (06) : 828 - 829
  • [9] THE HARDENING OF OPHTHALMIC LENSES
    DEUBERRY, HB
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1946, 36 (12) : 712 - 712
  • [10] Power of ophthalmic lenses
    Eggers, H