Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences

被引:70
|
作者
Kakeda, Shingo
Korogi, Yukunori
Hiai, Yasuhiro
Ohnari, Norihiro
Moriya, Junji
Kamada, Koji
Hanamiya, Mai
Sato, Toru
Kitajima, Mika
机构
[1] Univ Occupat & Environm Hlth, Sch Med, Dept Radiol, Yahatanishi Ku, Kitakyushu, Fukuoka 8078555, Japan
[2] Kumamoto Univ, Sch Med, Dept Radiol, Kitakyushu, Fukuoka 8078555, Japan
关键词
3T MRI; brain metastasis; contrast-enhanced sequence; 3D fast spoiled gradient-echo sequence; CONTRAST ENHANCEMENT; INITIAL-EXPERIENCE; MP-RAGE; 3.0; T; ECHO; TUMORS; MR; RESOLUTION; 1.5-TESLA; 3-TESLA;
D O I
10.1007/s00330-007-0599-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study is to compare the detectability of brain metastases at 3T among three contrast-enhanced sequences, spin-echo (SE) sequence, inversion recovery fast SE (IR-FSE) sequence (both with section thickness of 6 mm), and three-dimensional fast spoiled gradient-echo (3D fast SPGR) sequence with 1.4 mm isotropic voxel. First, phantom studies were performed to quantify the contrast-enhancement ratio (CER) with three sequences. In 21 consecutive patients with brain metastases, axial images of three sequences at 3T were obtained after administration of gadoteridol. Two neuroradiologists assessed the detectability of brain metastases for the three sequences. In the phantom study, no evident difference in the CER was demonstrated among three sequences. Significantly more brain metastases were detected with 3D fast SPGR than with SE and IR-FSE (a total of 97 lesions with 3D fast SPGR vs. 64 with SE and 63 with IR-FSE). In particular, 3D fast SPGR was superior to the other two sequences in detection of the small lesions (<3 mm). At 3T, the contrast-enhanced 3D fast SPGR with 1.4 mm isotropic voxel is clinically more valuable for detecting small brain metastases than the SE and IR-FSE with section thickness of 6 mm.
引用
收藏
页码:2345 / 2351
页数:7
相关论文
共 50 条
  • [21] Assessment of sedated pediatric brain with 3D-FLAIR sequence at 3T MRI
    Ozcan, Umit Aksoy
    Isik, Ugur
    Ozpinar, Alp
    Baykan, Nigar
    Dincer, Alp
    BRAIN & DEVELOPMENT, 2015, 37 (05): : 495 - 500
  • [22] Comparison of Sagittal FSE T2, STIR, and T1-Weighted Phase-Sensitive Inversion Recovery in the Detection of Spinal Cord Lesions in MS at 3T
    Alcaide-Leon, P.
    Pauranik, A.
    Alshafai, L.
    Rawal, S.
    Oh, J.
    Montanera, W.
    Leung, G.
    Bharatha, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (05) : 970 - 975
  • [23] Comparison of FSE T2W and 3D FIESTA sequences in the evaluation of posterior fossa cranial nerves with MR cisternography
    Hatipoglu, Hatice Guel
    Durakoglugil, Tugba
    Ciliz, Deniz
    Yueksel, Enis
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2007, 13 (02): : 56 - 60
  • [24] Comparison of FSE T2 W PROPELLER and 3D-FIESTA of 3 T MR for the internal auditory canal
    Wu, Hai-bo
    Yuan, Hui-shu
    Ma, Furong
    Zhao, Qiang
    CLINICAL IMAGING, 2017, 45 : 30 - 33
  • [25] Retrospective comparison of routine brain MRI scans in patients at 0.55 T and 1.5/3T
    Lavrova, Anna
    Mishra, Shruti
    Kim, John
    Lobo, Remy
    Masotti, Maria
    Richardson, Jacob
    Itriago-Leon, Pedro
    Gulani, Vikas
    Wright, Katherine
    Kelsey, Lauren
    Srinivasan, Ashok
    Seiberlich, Nicole
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 184
  • [26] Comparison of central vein detection in MS at 1.5T, 3T and 7T
    Fechner, A.
    Savatovsky, J.
    Sadik, J-C.
    Reich, D. S.
    Roux, P.
    Sati, P.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 680 - 680
  • [27] MS cortical lesions classification in different brain areas: comparison between 3D-DIR and magnetisation-prepared 3D-FLAIR at 3T
    Ganazzoli, C.
    Tona, F.
    Graziuso, S.
    Filice, S.
    Crisi, G.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 559 - 559
  • [28] Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
    Teixeira, Tiago
    Hafyane, Tarik
    Stikov, Nikola
    Akdeniz, Cansu
    Greiser, Andreas
    Friedrich, Matthias G.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18 : 1 - 12
  • [29] Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
    Tiago Teixeira
    Tarik Hafyane
    Nikola Stikov
    Cansu Akdeniz
    Andreas Greiser
    Matthias G. Friedrich
    Journal of Cardiovascular Magnetic Resonance, 18
  • [30] Analysis of the effect of motion on highly accelerated 3D FatNavs in 3D brain images acquired at 3T
    Marchetto, Elisa
    Gallichan, Daniel
    PLOS ONE, 2024, 19 (07):