Shading correction for cone-beam CT in radiotherapy: Validation of dose calculation accuracy using clinical images

被引:1
作者
Marchant, T. E. [1 ,2 ]
Joshi, K. D. [2 ]
Moore, C. J. [1 ,2 ]
机构
[1] Univ Manchester, Manchester Acad Hlth Sci Ctr, Christie NHS Fdn Trust, Manchester M20 4BX, Lancs, England
[2] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester M20 4BX, Lancs, England
来源
MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING | 2017年 / 10132卷
基金
英国医学研究理事会;
关键词
CLIN (clinical evaluation); CTCB (cone-beam CT); ONC (oncology); RADIATION-THERAPY; COMPUTED-TOMOGRAPHY; REGISTRATION; SCATTER;
D O I
10.1117/12.2254059
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cone-beam CT (CBCT) images are routinely acquired to verify patient position in radiotherapy (RT), but are typically not calibrated in Hounsfield Units (HU) and feature non-uniformity due to X-ray scatter and detector persistence effects. This prevents direct use of CBCT for re-calculation of RT delivered dose. We previously developed a prior-image based correction method to restore HU values and improve uniformity of CBCT images. Here we validate the accuracy with which corrected CBCT can be used for dosimetric assessment of RT delivery, using CBCT images and RT plans for 45 patients including pelvis, lung and head sites. Dose distributions were calculated based on each patient's original RT plan and using CBCT image values for tissue heterogeneity correction. Clinically relevant dose metrics were calculated (e.g. median and minimum target dose, maximum organ at risk dose). Accuracy of CBCT based dose metrics was determined using an "override ratio" method where the ratio of the dose metric to that calculated on a bulk-density assigned version of the image is assumed to be constant for each patient, allowing comparison to "gold standard" CT. For pelvis and head images the proportion of dose errors >2% was reduced from 40% to 1.3% after applying shading correction. For lung images the proportion of dose errors >3% was reduced from 66% to 2.2%. Application of shading correction to CBCT images greatly improves their utility for dosimetric assessment of RT delivery, allowing high confidence that CBCT dose calculations are accurate within 2-3%.
引用
收藏
页数:11
相关论文
共 20 条
[1]   RESULTS OF A MULTI-INSTITUTION DEFORMABLE REGISTRATION ACCURACY STUDY (MIDRAS) [J].
Brock, Kristy K. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (02) :583-596
[2]   Comparison of CT number calibration techniques for CBCT-based dose calculation [J].
Dunlop, Alex ;
McQuaid, Dualta ;
Nill, Simeon ;
Murray, Julia ;
Poludniowski, Gavin ;
Hansen, Vibeke N. ;
Bhide, Shreerang ;
Nutting, Christopher ;
Harrington, Kevin ;
Newbold, Kate ;
Oelfke, Uwe .
STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (12) :970-978
[3]  
Fan Q., 2015, J APPL CLIN MED PHYS, V16
[4]  
Joshi K., 2017, P SPIE MED IMAGING 2
[5]   An empirical method for lag correction in cone-beam CT [J].
Mail, N. ;
Moseley, D. J. ;
Siewerdsen, J. H. ;
Jaffray, D. A. .
MEDICAL PHYSICS, 2008, 35 (11) :5187-5196
[6]   Shading correction algorithm for improvement of cone-beam CT images in radiotherapy [J].
Marchant, T. E. ;
Moore, C. J. ;
Rowbottom, C. G. ;
MacKay, R. I. ;
Williams, P. C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20) :5719-5733
[7]   Reduction of motion artefacts in on-board cone beam CT by warping of projection images [J].
Marchant, T. E. ;
Price, G. J. ;
Matuszewski, B. J. ;
Moore, C. J. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (999) :251-264
[8]   X-ray volumetric imaging in image-guided radiotherapy: The new standard in on-treatment imaging [J].
McBain, CA ;
Henry, AM ;
Sykes, J ;
Amer, A ;
Marchant, T ;
Moore, CM ;
Davies, J ;
Stratford, J ;
McCarthy, C ;
Porritt, B ;
Williams, P ;
Khoo, VS ;
Price, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :625-634
[9]   Validation of a deformable image registration technique for cone beam CT-based dose verification [J].
Moteabbed, M. ;
Sharp, G. C. ;
Wang, Y. ;
Trofimov, A. ;
Efstathiou, J. A. ;
Lu, H. -M. .
MEDICAL PHYSICS, 2015, 42 (01) :196-205
[10]   Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images [J].
Niu, Tianye ;
Sun, Mingshan ;
Star-Lack, Josh ;
Gao, Hewei ;
Fan, Qiyong ;
Zhu, Lei .
MEDICAL PHYSICS, 2010, 37 (10) :5395-5406