Comparison of derivatization/ionization techniques for liquid chromatography tandem mass spectrometry analysis of oxylipins

被引:21
|
作者
Meckelmann, Sven W. [1 ,2 ]
Hellhake, Stefan [1 ]
Steuck, Maryvonne [1 ]
Krohn, Michael [1 ]
Schebb, Nils Helge [1 ,3 ]
机构
[1] Univ Wuppertal, Fac Math & Nat Sci, Chair Food Chem, Wuppertal, Germany
[2] Cardiff Univ, Inst Infect & Immun, Sch Med, Cardiff, S Glam, Wales
[3] Univ Vet Med Hannover, Inst Food Toxicol & Analyt Chem, Hannover, Germany
关键词
Lipidomics; Eicosanoids; Oxylipins; Liquid chromatography mass spectrometry; Derivatization; AMPP; CHARGE REVERSAL DERIVATIZATION; CHEMICAL-IONIZATION; EICOSANOIDS; SENSITIVITY; SUPPRESSION; LIPIDOMICS; PLASMA; MS/MS; ACIDS;
D O I
10.1016/j.prostaglandins.2017.02.003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The performance of two derivatization and ionization techniques for the quantitative reversed phase liquid chromatography (LC)-mass spectrometry (MS) analysis of hydroxy fatty acids (OH-PUFA) in plasma was evaluated: One used AMPP (N-(4-aminomethylphenyl)pyridinium chloride) leading to a positive charged amid-derivate which can be detected by electrospray ionization (ESI)-MS. Second yielded penta fluorobenzyl bromide (PFB) ester derivates allowing detection in electron capture atmospheric pressure chemical ionization (ecAPCI)-MS. The sensitivity of detection of a comprehensive set of hydroxy fatty acids of n6- and n3-poly unsaturated fatty acids was investigated. On the SCIEX3200 MS the applied PFB derivatization led to poor limits of detection (LOD) of 10-100 nM (0.1-1 pmo1/0.03-0.3 ng on column). By contrast, AMPP derivatization led to a similar sensitivity compared to the standard ESI(-) of non derivatized analytes (LOD about 1 nM (10 fmol/3 pg on column)). For several analytes, including 9-HETE, 11-HETE and 17-HDHA the AMPP derivatization improved sensitivity enabling their detection in human plasma. However, precision was reduced by AMPP derivatization and variation in IS recovery indicated a strong matrix influence on the MS-signal. In sum, with the instrumentation used, neither of these derivatization methods improves in our hands the LC-MS based quantification of oxylipins. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 50 条
  • [21] Analysis of tomato glycoalkaloids by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Cataldi, TRI
    Lelario, F
    Bufo, SA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (21) : 3103 - 3110
  • [22] Multiplexed targeted analysis of polyunsaturated fatty acids and oxylipins using liquid chromatography- tandem mass spectrometry
    Turtoi, Evgenia
    Jeudy, Jeremy
    Valette, Gilles
    Enjalbal, Christine
    Vila, Isabelle K.
    Laguette, Nadine
    Turtoi, Andrei
    STAR PROTOCOLS, 2023, 4 (03):
  • [23] Profiling degradants of paclitaxel using liquid chromatography mass spectrometry and liquid chromatography tandem mass spectrometry substructural techniques
    Volk, KJ
    Hill, SE
    Kerns, EH
    Lee, MS
    JOURNAL OF CHROMATOGRAPHY B, 1997, 696 (01): : 99 - 115
  • [25] Simplification of analytical methods in pesticide residue analysis by liquid chromatography electrospray ionization mass spectrometry and tandem mass spectrometry
    Stout, SJ
    daCunha, AR
    Picard, GL
    Safarpour, MM
    JOURNAL OF AOAC INTERNATIONAL, 1998, 81 (04) : 685 - 690
  • [26] Comparison of evaporation techniques for the preparation of salivary cortisol for analysis by liquid chromatography-electrospray tandem mass spectrometry
    Nelson, Elizabeth A.
    Palombo, Enzo A.
    Knowles, Simon R.
    CLINICAL BIOCHEMISTRY, 2008, 41 (16-17) : 1413 - 1416
  • [27] Derivatization enhances analysis of estrogens and their bioactive metabolites in human plasma by liquid chromatography tandem mass spectrometry
    Denver, Nina
    Khan, Shazia
    Stasinopoulos, Ioannis
    Church, Colin
    Homer, Natalie Z. M.
    MacLean, Margaret R.
    Andrew, Ruth
    ANALYTICA CHIMICA ACTA, 2019, 1054 : 84 - 94
  • [28] Comparison of negative and positive ion electrospray tandem mass spectrometry for the liquid chromatography tandem mass spectrometry analysis of oxidized deoxynucleosides
    Hua, YS
    Wainhaus, SB
    Yang, YN
    Shen, LX
    Xiong, YS
    Xu, XY
    Zhang, FG
    Bolton, JL
    van Breemen, RB
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (01) : 80 - 87
  • [29] On-line derivatization of peptides for improved sequence analysis by micro-column liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Cardenas, MS
    vanderHeeft, E
    deJong, APJM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (12) : 1271 - 1278
  • [30] Derivatization for liquid chromatography-mass spectrometry
    Qi, Bao-Ling
    Liu, Ping
    Wang, Qiu-Yi
    Cai, Wen-Jing
    Yuan, Bi-Feng
    Feng, Yu-Qi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 59 : 121 - 132