Comparison of derivatization/ionization techniques for liquid chromatography tandem mass spectrometry analysis of oxylipins

被引:21
|
作者
Meckelmann, Sven W. [1 ,2 ]
Hellhake, Stefan [1 ]
Steuck, Maryvonne [1 ]
Krohn, Michael [1 ]
Schebb, Nils Helge [1 ,3 ]
机构
[1] Univ Wuppertal, Fac Math & Nat Sci, Chair Food Chem, Wuppertal, Germany
[2] Cardiff Univ, Inst Infect & Immun, Sch Med, Cardiff, S Glam, Wales
[3] Univ Vet Med Hannover, Inst Food Toxicol & Analyt Chem, Hannover, Germany
关键词
Lipidomics; Eicosanoids; Oxylipins; Liquid chromatography mass spectrometry; Derivatization; AMPP; CHARGE REVERSAL DERIVATIZATION; CHEMICAL-IONIZATION; EICOSANOIDS; SENSITIVITY; SUPPRESSION; LIPIDOMICS; PLASMA; MS/MS; ACIDS;
D O I
10.1016/j.prostaglandins.2017.02.003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The performance of two derivatization and ionization techniques for the quantitative reversed phase liquid chromatography (LC)-mass spectrometry (MS) analysis of hydroxy fatty acids (OH-PUFA) in plasma was evaluated: One used AMPP (N-(4-aminomethylphenyl)pyridinium chloride) leading to a positive charged amid-derivate which can be detected by electrospray ionization (ESI)-MS. Second yielded penta fluorobenzyl bromide (PFB) ester derivates allowing detection in electron capture atmospheric pressure chemical ionization (ecAPCI)-MS. The sensitivity of detection of a comprehensive set of hydroxy fatty acids of n6- and n3-poly unsaturated fatty acids was investigated. On the SCIEX3200 MS the applied PFB derivatization led to poor limits of detection (LOD) of 10-100 nM (0.1-1 pmo1/0.03-0.3 ng on column). By contrast, AMPP derivatization led to a similar sensitivity compared to the standard ESI(-) of non derivatized analytes (LOD about 1 nM (10 fmol/3 pg on column)). For several analytes, including 9-HETE, 11-HETE and 17-HDHA the AMPP derivatization improved sensitivity enabling their detection in human plasma. However, precision was reduced by AMPP derivatization and variation in IS recovery indicated a strong matrix influence on the MS-signal. In sum, with the instrumentation used, neither of these derivatization methods improves in our hands the LC-MS based quantification of oxylipins. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 50 条
  • [1] Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry
    Santa, Tomofumi
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (1-2) : 1 - 10
  • [2] Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry for biomedical analysis
    Santa, Tomofumi
    Al-Dirbashi, Osama Y.
    Fukushima, Takeshi
    DRUG DISCOVERIES AND THERAPEUTICS, 2007, 1 (02): : 108 - 118
  • [3] Isothiocyanates as derivatization reagents for amines in liquid chromatography/electrospray ionization-tandem mass spectrometry
    Santa, Tomofumi
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (09) : 915 - 918
  • [4] Electrospray ionization mass spectrometry of tetrodotoxin and its analogs: Liquid chromatography/mass spectrometry, tandem mass spectrometry, and liquid chromatography/tandem mass spectrometry
    Shoji, Y
    Yotsu-Yamashita, M
    Miyazawa, T
    Yasumoto, T
    ANALYTICAL BIOCHEMISTRY, 2001, 290 (01) : 10 - 17
  • [5] Analysis of phosphorylated terpenes by electrospray ionization liquid chromatography tandem mass spectrometry
    Ney, I
    Jager, E
    Herderich, M
    Schreier, P
    Schwab, W
    PHYTOCHEMICAL ANALYSIS, 1996, 7 (05) : 233 - 236
  • [6] Analysis of omnoponum by surface-ionization mass spectrometry and liquid chromatography tandem mass spectrometry methods
    Usmanov, Dilshadbek
    Khasanov, Usman
    Pantsirev, Aleksey
    Van Bocxlaer, Jan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 53 (04) : 1058 - 1062
  • [7] Forensic toxicological determination of surfactant by liquid chromatography/electrospray ionization mass spectrometry and liquid chromatography/electrospray ionization tandem mass spectrometry
    Nishikawa, M
    Katagi, M
    Miki, A
    Tsuchihashi, H
    JOURNAL OF HEALTH SCIENCE, 2003, 49 (02) : 138 - 148
  • [8] Systematic Profile of Oxylipins in Myocardial Infarction by Liquid Chromatography-Tandem Mass Spectrometry
    Tan, Xin
    Ni, Hui
    Li, Qin
    Ma, Zhanglin
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2025, 39 (09)
  • [9] Development of sensitive derivatization method for aldosterone in liquid chromatography-electrospray ionization tandem mass spectrometry of corticosteroids
    Yamashita, Kouwa
    Okuyama, Mitsunobu
    Nakagawa, Risa
    Honma, Seijiro
    Satoh, Fumitoshi
    Morimoto, Ryo
    Ito, Sadayoshi
    Takahashi, Madoka
    Numazawa, Mitsuteru
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1200 (02) : 114 - 121
  • [10] Liquid chromatography/electrospray ionization tandem mass spectrometry and derivatization for the identification of polar carbonyl disinfection by-products
    Zwiener, C
    Glauner, T
    Frimmel, FH
    LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY, MS/MS AND TIME-OF-FLIGHT MS, 2003, 850 : 356 - 375