Comparison of the sensitivities of seven N-nitrosamines in pre-screened waters using an automated preconcentration system and gas chromatography with different detectors

被引:34
作者
Jurado-Sanchez, Beatriz
Ballesteros, Evaristo
Gallego, Mercedes
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
[2] Univ Jaen, EPS Linares, Dept Phys & Analyt Chem, E-23700 Jaen, Spain
关键词
screening; solid-phase extraction; photometry; gas chromatography; N-nitrosamines; waters;
D O I
10.1016/j.chroma.2007.03.117
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, expeditious procedure for confirming the presence of N-nitrosamines in previously screened positive water samples was proposed. Water samples were continuously aspirated into a photometric flow system for screening. Positive samples were then confirmed and N-nitrosamines were identified by gas chromatography using different detectors (mass spectrometry, flame ionization and nitrogen-phosphorus). The system for the screening purpose was based on the preconcentration of the analytes onto a sorbent column, elution, and derivatization to form nitrite, then formation of a coloured product (Griess reaction) and photometric detection. The detection limits of the gas chromatographic method for 100 ml of sample were 2.0-3.5 mu g/l, 20-80 and 3-13 ng/l for flame ionization, nitrogen-phosphorus and mass spectrometric detectors, respectively. The precision as RSD was similar for all detectors (3.0-6.5%). The screening of different types of water showed that wastewaters contain levels of N-nitrosamines that can be detected only using MS as a detector. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 73
页数:8
相关论文
共 29 条
[1]  
Perera AMA, 2006, CHROMATOGR SCI SER, V93, P419
[2]   Adsorption of N-nitrosodiethylamine and N-nitrosodimethylamine on activated carbon:: A pre-concentration procedure for gas chromatographic analysis [J].
Aygün, SF ;
Uyanik, A ;
Bati, B .
MICROCHIMICA ACTA, 2004, 146 (3-4) :279-283
[3]   Selective photo-reduction of N-nitroamines combined with micellar electrokinetic chromatography and laser fluorimetric detection [J].
Bell, LM ;
Murray, GM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 826 (1-2) :160-168
[4]   Analysis of N-nitrosamines by high-performance liquid chromatography with post-column photohydrolysis and colorimetric detection [J].
Bellec, G ;
Cauvin, JM ;
Salaun, MC ;
LeCalve, K ;
Dreano, Y ;
Gouerou, H ;
Menez, JF ;
Berthou, F .
JOURNAL OF CHROMATOGRAPHY A, 1996, 727 (01) :83-92
[5]   Determination of volatile N-nitrosamines in irradiated fermented sausage by gas chromatography coupled to a thermal energy analyzer [J].
Byun, MW ;
Ahn, HJ ;
Kim, JH ;
Lee, JW ;
Yook, HS ;
Han, SB .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1054 (1-2) :403-407
[6]   High-performance liquid chromatography with fluorescence detection for aqueous analysis of nanogram-level N-nitrosodimethylamine [J].
Cha, W ;
Fox, P ;
Nalinakumari, B .
ANALYTICA CHIMICA ACTA, 2006, 566 (01) :109-116
[7]   Detecting N-nitrosamines in drinking water at nanogram per liter levels using ammonia positive chemical ionization [J].
Charrois, JWA ;
Arend, MW ;
Froese, KL ;
Hrudey, SE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (18) :4835-4841
[8]   N-nitrosodimethylamine formation hy free-chlorine-enhanced nitrosation of dimethylamine [J].
Choi, JH ;
Valentine, RL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (21) :4871-4876
[9]   IDENTIFICATION AND QUANTITATION OF N-NITROSAMINES IN HUMAN POSTMORTEM ORGANS [J].
COOPER, SF ;
LEMOYNE, C ;
GAUVREAU, D .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1987, 11 (01) :12-18
[10]   Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995) [J].
Currie, LA .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :105-126