Evaluation of Seegene Allplex Respiratory Panel 1 kit for the detection of influenza virus and human respiratory syncytial virus

被引:17
作者
Gimferrer, Laura [1 ]
Andres, Cristina [1 ]
Rando, Ariadna [1 ]
Pinana, Maria [1 ]
Gema Codina, Maria [1 ]
del Carmen Martin, Maria [1 ]
Fuentes, Francisco [1 ]
Rubio, Susana [1 ]
Alcubilla, Pilar [1 ]
Pumarola, Tomas [1 ]
Anton, Andres [1 ]
机构
[1] Univ Autonoma Barcelona, Hosp Univ Vall dHebron, Vall dHebron Res Inst, Virol Unit,Microbiol Dept, Passeig Vall dHebron 119-129, Barcelona, Spain
关键词
Influenza viruses; Human respiratory syncytial virus; Real-time; RT-PCR; Epidemiology;
D O I
10.1016/j.jcv.2018.05.006
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Influenza (FLUV) and human respiratory syncytial (HRSV) viruses are etiological agents of respiratory infections that cause a significant morbidity and mortality worldwide. A rapid and accurate diagnosis of these respiratory viruses is essential for an appropriate patient management. Molecular tests are the best detection option due to their high sensitivity and specificity. Seegene's Allplex (TM) Respiratory Panel 1 (Allplex RP1) is a real-time one-step RT-PCR assay for the simultaneous detection of FLUAV, FLUBV, HRSV-A and HRSV-B. In addition, it allows the determination of FLUAV subtype (H1, H3 and H1pdm09). Objectives: This study aims to evaluate Allplex RP1 as a rapid molecular test for the detection of FLUAV, FLUBV, HRSV-A and HRSV-B viruses. Study design: The Allplex RP1 assay will be compared with other two commercial molecular assays, Prodesse ProFlu+ and ProFAST+ (Hologic, Madison, WI, USA), and GeneXpert Flu/RSV XC (Cepheid, USA). Results: Allplex RP1, ProFlu+ and GeneXpert tests showed 95%, 91% and 96% of accuracy; and 94%, 88% and 95% of sensitivity, respectively. Moreover, Allplex RP1 showed a FLUAV subtype sensitivity of 91% and 88% for FLUAV-H1pdm09 and FLUAV-H3 respectively, and ProFAST+ assay showed sensitivities of 100% for both targets. The three assays showed a 100% of specificity and PPV, while the NPV were 84%, 73% and 86% for Allplex RP1, Prodesse and GeneXpert, respectively. Conclusions: In this study, Seegene's Allplex RP1 assay showed to be highly sensitive, specific, and suitable for detection of FLUV and HRSV, including FLUAV subtyping. In addition, it is also a hands-on-time saving assay due to the automated nucleic acid extraction and PCR setup.
引用
收藏
页码:31 / 34
页数:4
相关论文
共 13 条
[1]  
[Anonymous], 2001, GUID IND BIOAN METH
[2]  
[Anonymous], 2009, FACT SHEET
[3]   Evaluation of a new, rapid, simple test for the detection of influenza virus [J].
Carlos Hurtado, Juan ;
Mar Mosquera, Maria ;
de Lazzari, Elisa ;
Martinez, Esteban ;
Torner, Nuria ;
Isanta, Ricard ;
de Molina, Patricia ;
Pumarola, Tomas ;
Angeles Marcos, Maria ;
Vila Estape, Jordi .
BMC INFECTIOUS DISEASES, 2015, 15
[4]   Genetic Variability of Human Respiratory Syncytial Virus A Strains Circulating in Ontario: A Novel Genotype with a 72 Nucleotide G Gene Duplication [J].
Eshaghi, AliReza ;
Duvvuri, Venkata R. ;
Lai, Rachel ;
Nadarajah, Jeya T. ;
Li, Aimin ;
Patel, Samir N. ;
Low, Donald E. ;
Gubbay, Jonathan B. .
PLOS ONE, 2012, 7 (03)
[5]   Molecular epidemiology and molecular characterization of respiratory syncytial viruses at a tertiary care university hospital in Catalonia (Spain) during the 2013-2014 season [J].
Gimferrer, Laura ;
Campins, Magda ;
Gema Codina, Maria ;
del Carmen Martin, Maria ;
Fuentes, Francisco ;
Esperalba, Juliana ;
Bruguera, Andreu ;
Maria Vilca, Luz ;
Armadans, Lluis ;
Pumarola, Tomas ;
Anton, Andres .
JOURNAL OF CLINICAL VIROLOGY, 2015, 66 :27-32
[6]  
Kim Yiseul, 2016, Korean Journal of Applied Entomology, V55, P1, DOI 10.5656/KSAE.2015.10.0.031
[7]   Evaluation of Three Automated Nucleic Acid Extraction Systems for Identification of Respiratory Viruses in Clinical Specimens by Multiplex Real-Time PCR [J].
Kim, Yoonjung ;
Han, Mi-Soon ;
Kim, Juwon ;
Kwon, Aerin ;
Lee, Kyung-A .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[8]   Comparison of the Luminex xTAG Respiratory Viral Panel Fast v2 Assay With Anyplex II RV16 Detection Kit and AdvanSure RV Real-Time RT-PCR Assay for the Detection of Respiratory Viruses [J].
Ko, Dae-Hyun ;
Kim, Hyun Soo ;
Hyun, Jungwon ;
Kim, Han -Sung ;
Kim, Jae-Seok ;
Park, Kyoung Un ;
Song, Wonkeun .
ANNALS OF LABORATORY MEDICINE, 2017, 37 (05) :408-414
[9]   Development and application of a triplex real-time PCR assay for the simultaneous detection of avian influenza virus subtype H5, H7 and H9 [J].
Liu, Junli ;
Yao, Lu ;
Zhai, Feifei ;
Chen, Yuqing ;
Lei, Jing ;
Bi, Zhenwei ;
Hu, Jianhua ;
Xiao, Qian ;
Song, Suquan ;
Yan, Liping ;
Zhou, Jiyong .
JOURNAL OF VIROLOGICAL METHODS, 2018, 252 :49-56
[10]   Comparative Evaluation of Six Commercialized Multiplex PCR Kits for the Diagnosis of Respiratory Infections [J].
Pillet, Sylvie ;
Lardeux, Marina ;
Dina, Julia ;
Grattard, Florence ;
Verhoeven, Paul ;
Le Goff, Jerome ;
Vabret, Astrid ;
Pozzetto, Bruno .
PLOS ONE, 2013, 8 (08)