Effect of fan-generated swirl on turbulent heat transfer and fluid flow in a pipe

被引:14
作者
Gorman, J. M. [1 ]
Sparrow, E. M. [1 ]
Ilamparuthi, S. [1 ]
Minkowycz, W. J. [2 ]
机构
[1] Univ Minnesota, Dept Mech Engn, 111 Church St SE, Minneapolis, MN 55455 USA
[2] Univ Illinois, Dept Mech & Ind Engn, Chicago, IL 60607 USA
关键词
Fan generated swirl; Rotating fan; Turbulent pipe flow; Heat transfer; CFD; Numerical simulation; PRESSURE-DROP CHARACTERISTICS; CIRCULAR TUBE;
D O I
10.1016/j.ijheatmasstransfer.2015.12.038
中图分类号
O414.1 [热力学];
学科分类号
摘要
Fan-generated swirl can be characterized as chaotic and strongly mixed. It differs from controlled swirl with respect to those characteristics that tend to increase both the rate of heat transfer and the pressure drop. In the investigation described here, a rotating fan simulation, which takes full account of the rotation of the fan blades and of the true nature of the delivered flow, was implemented with high fidelity. The fan output is delivered directly to the inlet of a round pipe. It is believed that this is the first time that such a realistic approach has been used. The air delivered to the pipe has a temperature different from that of the pipe wall. The swirl component is shown to give rise to a significant enhancement of heat transfer, from a factor of two to 50% between x/D = 0 and 20. Similar increases of the wall shear were also found to result from the swirl. As a comparison case, a blower curve for the fan in question was used. Since blower curves omit the swirl component, only a uniform axial flow can be extracted. The swirl effects on heat transfer and shear stress were obtained by comparing the results for the actual rotating-fan-provided flow with those for the blower curve model. In the absence of swirl, the axial distributions of the local heat transfer coefficient and wall shear displayed a local undershoot, thereby supporting limited earlier reporting of such happenings in simpler situations. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1019 / 1025
页数:7
相关论文
共 19 条
[1]   Heat transfer augmentation for the flow of a viscous liquid in circular tubes using twisted tape inserts [J].
Agarwal, SK ;
Rao, MR .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (17) :3547-3557
[2]   An experimental study and CFD analysis towards heat transfer and fluid flow characteristics of decaying swirl pipe flow generated by axial vanes [J].
Ahmadvand, M. ;
Najafi, A. F. ;
Shahidinejad, S. .
MECCANICA, 2010, 45 (01) :111-129
[3]   Perforated plates for fluid management: Plate geometry effects and flow regimes [J].
Bayazit, Yilmaz ;
Sparrow, Eph M. ;
Joseph, Daniel D. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 85 :104-111
[4]   APPLICATION OF ANN AND GA FOR THE PREDICTION AND OPTIMIZATION OF THERMAL AND FLOW CHARACTERISTICS IN A RECTANGULAR CHANNEL FITTED WITH TWISTED TAPE VORTEX GENERATORS [J].
Beigzadeh, Reza ;
Rahimi, Masoud ;
Parvizi, Mehdi ;
Eiamsa-ard, Smith .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2014, 65 (02) :186-199
[5]   A reinterpretation of the turbulent Prandtl number [J].
Churchill, SW .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (25) :6393-6401
[6]   An experimental investigation of the heat transfer and pressure drop characteristics of a circular tube fitted with rotating turbine-type swirl generators [J].
Duangthongsuk, Weerapun ;
Wongwises, Somchai .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 45 :8-15
[7]   3-D Numerical simulation of swirling flow and convective heat transfer in a circular tube induced by means of loose-fit twisted tapes [J].
Eiamsa-ard, S. ;
Wongcharee, K. ;
Sripattanapipat, S. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (09) :947-955
[8]   TURBULENT PRANDTL NUMBER - WHERE ARE WE [J].
KAYS, WM .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1994, 116 (02) :284-295
[9]  
Kreith F., 2001, Principles of Heat Transfer, V6th
[10]   Numerical investigations on effects of seven drag reduction components in elbow and T-junction close-coupled pipes [J].
Li, A. ;
Chen, X. ;
Chen, L. .
BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2015, 36 (03) :295-310