Atmospheric pressure-thermal desorption (AP-TD)/electrospray ionization-mass spectrometry for the rapid analysis of Bacillus spores

被引:23
作者
Basile, Franco [1 ]
Zhang, Shaofeng [1 ]
Shin, Yong-Seung [1 ]
Drolet, Barbara [2 ]
机构
[1] Univ Wyoming, Dept Chem, Laramie, WY 82071 USA
[2] Univ Wyoming, USDA, Laramie, WY 82071 USA
基金
美国国家科学基金会; 美国农业部; 美国国家卫生研究院;
关键词
EXTRACTIVE ELECTROSPRAY-IONIZATION; DIPICOLINIC ACID; BACTERIAL-SPORES; GAS CHROMATOGRAPHY; PYROLYSIS PRODUCTS; AMBIENT CONDITIONS; ION-SOURCE; QUALITY; DESI; MS;
D O I
10.1039/c0an00071j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A technique is described where an atmospheric pressure-thermal desorption (AP-TD) device and electrospray ionization (ESI)-mass spectrometry (MS) are coupled and used for the rapid analysis of Bacillus subtilis spores in complex matrices. The resulting AP-TD/ESI-MS technique combines the generation of volatile compounds and/or pyrolysis products with soft-ionization MS detection. In the AP-TD/ESI-MS approach, an electrospray solvent plume was used as the ionization vehicle of thermally desorbed neutrals at atmospheric pressure prior to mass spectrometric analysis using a quadrupole ion trap mass spectrometer. The approach is quantitative with the volatile standard dimethyl methylphosphonate (DMMP) and with the use of an internal standard (diethyl methylphosphonate, DEMP). A linear response was obtained as tested in the 1-50 ppm range (R(2) = 0.991) with a standard error of the estimate of 0.193 (0.9% RSD, n = 5). Bacterial spores were detected by performing pyrolysis in situ methylation with the reagent tetramethylammonium hydroxide (TMAH) for the detection of the bacterial spore biomarker dipicolinic acid (DPA) as the dimethylated derivative (2Me-DPA). This approach allowed spore detection even in the presence of growth media in crude lyophilized samples. Repetitive analyses could be performed with a duty cycle of less than 5 min total analysis time (including sample loading, heating and data acquisition). This strategy proved successful over other direct ambient MS approaches like DESI-MS and AP-TD/ESI-MS without the in situ derivatization step to detect the dipicolinic acid biomarker from spores. A detection limit for the dimethylated DPA biomarker was estimated at 1 ppm (equivalent to 0.01 mu g of DPA deposited in the thermal desorption tube), which corresponded to a calculated detection limit of 10(5) spores deposited or 0.1% by weight spore composition in solid samples (assuming a 1 mg sample size). The AP-TD/ESI source used in conjunction with the in situ methylation step allowed the differentiation of bacterial spores from other 'suspicious white powders' using a single stage for mass analysis and with minimum sample preparation, making this approach suitable for simple field-portable MS instrumentation and pattern recognition data analysis.
引用
收藏
页码:797 / 803
页数:7
相关论文
共 43 条
[1]   Single-shot biodiesel analysis:: Nearly instantaneous typification and quality control solely by ambient mass spectrometry [J].
Abdelnur, Patricia V. ;
Eberlin, Livia S. ;
de Sa, Gilberto F. ;
de Souza, Vanderlea ;
Eberlin, Marcos N. .
ANALYTICAL CHEMISTRY, 2008, 80 (20) :7882-7886
[2]   DIRECT MASS-SPECTROMETRY OF POLYMERS .13. THERMAL FRAGMENTATION PROCESSES IN POLY-ALPHA-AMINOACIDS [J].
BALLISTRERI, A ;
GIUFFRIDA, M ;
MARAVIGNA, P ;
MONTAUDO, G .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1985, 23 (04) :1145-1161
[3]   Pathogenic bacteria: their detection and differentiation by rapid lipid profiling with pyrolysis mass spectrometry [J].
Basile, F ;
Beverly, MB ;
Voorhees, KJ ;
Hadfield, TL .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (02) :95-109
[4]  
Beverly MB, 1996, RAPID COMMUN MASS SP, V10, P455, DOI 10.1002/(SICI)1097-0231(19960315)10:4<455::AID-RCM500>3.0.CO
[5]  
2-Y
[6]  
Chen H., 2007, FRONTIERS CNS ONCOLO
[7]   Differentiation of maturity and quality of fruit using noninvasive extractive electrospray ionization quadrupole time-of-flight mass spectrometry [J].
Chen, Huanwen ;
Sun, Yanping ;
Wortmann, Arno ;
Gu, Haiwei ;
Zenobi, Renato .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1447-1455
[8]   What Can We Learn from Ambient Ionization Techniques? [J].
Chen, Huanwen ;
Gamez, Gerardo ;
Zenobi, Renato .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (11) :1947-1963
[9]   Extractive electrospray ionization for direct analysis of undiluted urine, milk and other complex mixtures without sample preparation [J].
Chen, HW ;
Venter, A ;
Cooks, RG .
CHEMICAL COMMUNICATIONS, 2006, (19) :2042-2044
[10]   Rapid classification of perfumes by extractive electrospray ionization mass spectrometry (EESI-MS) [J].
Chingin, Konstantin ;
Gamez, Gerardo ;
Chen, Huanwen ;
Zhu, Liang ;
Zenobi, Renato .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (13) :2009-2014