Malaligned Dynamic Anterior Cervical Plate

被引:10
作者
Lawrence, Brandon D. [1 ]
Patel, Alpesh A. [2 ]
Guss, Andrew [1 ]
Spiker, W. Ryan [1 ]
Brodke, Darrel S. [1 ]
机构
[1] Univ Utah, Dept Orthopaed, Salt Lake City, UT 84108 USA
[2] Northwestern Univ, Dept Orthopaed, Chicago, IL 60611 USA
关键词
anterior cervical; dynamic plate; biomechanics; radiculopathy; discectomy; arthrodesis; myelopathy; spine; FUSION; SPINE; FIXATION; REMOVAL;
D O I
10.1097/BRS.0000000000000630
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Biomechanical evaluation. Objective. To evaluate the kinematic and load-sharing differences of dynamic anterior cervical plates when placed in-line at 0 degrees and off-axis at 20 degrees. Summary of Background Data. The use of dynamic anterior cervical plating systems has recently gained popularity due to the theoretical benefit of improved load sharing with graft subsidence. Occasionally, due to anatomical restraints, the anterior cervical plate may be placed off-axis in the coronal plane. This may potentially decrease the dynamization capability of the plate, leading to less load sharing and potentially decreased fusion rates. The purpose of this study was to comprehensively evaluate the kinematic and load-sharing differences of a dynamic plate placed in-line versus off-axis in the coronal plane. Methods. Thirteen fresh-frozen human cadaveric cervical spines (C2-T1) were used. Nondestructive range-of-motion testing was performed with a pneumatically controlled spine simulator in flexion/extension, lateral bending, and axial rotation using the OptoTrak motion measurement system. A C5 corpectomy was performed, and a custom interbody spacer with an integrated load cell collected load-sharing data under axial compression at varying loads. A dynamic anterior cervical plate was placed in-line at 0 degrees and then off-axis at 20 degrees. Testing conditions ensued using a full-length spacer, followed by simulated subsidence by removing 10% of the height of the original spacer. Results. There were no kinematic differences noted in the in-line model versus the off-axis model. After simulated subsidence, the small decreases in stiffness and increases in motion were similar whether the plate was placed in-line or off-axis in all 3 planes of motion. There were also no significant differences in the load-sharing characteristics of the in-line plate versus the off-axis plate in either the full-length model or the subsided interbody model. Conclusion. This study suggests that off-axis dynamic plate positioning does not significantly impact construct kinematics or graft load sharing. As such, we do not recommend removal or repositioning of an off-axis placed dynamic plate because the kinematic and load-sharing biomechanical properties are similar.
引用
收藏
页码:2057 / 2061
页数:5
相关论文
共 11 条
[1]   Anterior cervical fixation: Analysis of load-sharing and stability with use of static and dynamic plates [J].
Brodke, Darrel S. ;
Klimo, Paul, Jr. ;
Bachus, Kent N. ;
Braun, John T. ;
Dailey, Andrew T. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (07) :1566-1573
[2]   ANTERIOR CERVICAL FUSION AND CASPAR PLATE STABILIZATION FOR CERVICAL TRAUMA [J].
CASPAR, W ;
BARBIER, DD ;
KLARA, PM .
NEUROSURGERY, 1989, 25 (04) :491-502
[3]   THE ANTERIOR APPROACH FOR REMOVAL OF RUPTURED CERVICAL DISKS [J].
CLOWARD, RB .
JOURNAL OF NEUROSURGERY, 1958, 15 (06) :602-617
[4]  
Connolly PJ, 1996, J SPINAL DISORD, V9, P202
[5]   Dynamic Plates in Anterior Cervical Fusion Surgery Graft Settling and Cervical Alignment [J].
Ghahreman, Ali ;
Rao, Prashanth J. V. ;
Ferch, Richard D. .
SPINE, 2009, 34 (15) :1567-1571
[6]   Biomechanics of Halo-Vest and Dens Screw Fixation for Type II Odontoid Fracture [J].
Ivancic, Paul C. ;
Beauchman, Naseem N. ;
Mo, Fred ;
Lawrence, Brandon D. .
SPINE, 2009, 34 (05) :484-490
[7]   THE STABILIZING SYSTEM OF THE SPINE .2. NEUTRAL ZONE AND INSTABILITY HYPOTHESIS [J].
PANJABI, MM .
JOURNAL OF SPINAL DISORDERS, 1992, 5 (04) :390-397
[8]   Implant Complications, Fusion, Loss of Lordosis, and Outcome After Anterior Cervical Plating With Dynamic or Rigid Plates Two-Year Results of a Multi-Centric, Randomized, Controlled Study [J].
Pitzen, Tobias R. ;
Chrobok, Jiri ;
Stulik, Jan ;
Ruffing, Sabine ;
Drumm, Joerg ;
Sova, Laurentius ;
Kucera, Roman ;
Vyskocil, Tomas ;
Steudel, Wolf Ingo .
SPINE, 2009, 34 (07) :641-646
[9]   Cervical spine loading characteristics in a cadaveric C5 corpectomy model using a static and dynamic plate [J].
Reidy, D ;
Finkelstein, J ;
Nagpurkar, A ;
Mousavi, P ;
Whyne, C .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (02) :117-122
[10]   THE TREATMENT OF CERTAIN CERVICAL-SPINE DISORDERS BY ANTERIOR REMOVAL OF THE INTERVERTEBRAL DISC AND INTERBODY FUSION [J].
SMITH, GW ;
ROBINSON, RA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1958, 40 (03) :607-624