Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis

被引:7
|
作者
Kelderman, Jeroen R. [1 ]
Jolink, Floris E. J. [2 ]
Benjamens, Stan [1 ,2 ]
Monroy-Gonzalez, Andrea G. [1 ]
Pol, Robert A. [2 ]
Slart, Riemer H. J. A. [1 ,3 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Med Imaging Ctr, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Div Transplant Surg, Dept Surg, Groningen, Netherlands
[3] Univ Twente, Fac Sci & Technol, Dept Biomed Photon Imaging, Enschede, Netherlands
关键词
End-stage renal disease; Myocardial perfusion imaging; Invasive coronary angiography; Coronary artery disease; Diagnosis; Systematic review; Meta-analysis; CORONARY-ARTERY-DISEASE; CANDIDATES; SPECT; ANGIOGRAPHY; MANAGEMENT; PREDICTOR; EVENTS;
D O I
10.1007/s12350-021-02621-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiovascular disease is the most common cause of death after kidney transplantation. Coronary artery disease (CAD) assessment is therefore mandatory in patients evaluated for transplantation. We aimed to assess the diagnostic accuracy for CAD of single-photon emission computed tomography (SPECT) compared to the standards invasive coronary angiography (ICA) and coronary computed tomography angiography (CCTA) in patients evaluated for kidney transplantation. Methods We performed a systematic literature search in PubMed, EMBASE, Web of Science, OvidSP (Medline), The Cochrane Library and Google Scholar. Studies investigating the diagnostic accuracy of myocardial perfusion imaging (MPI) SPECT in patients evaluated for kidney transplantation were retrieved. After a risk of bias assessment using QUADAS-2, a meta-analysis was conducted. Results Out of 1459 records, 13 MPI SPECT studies were included in the meta-analysis with a total of 1245 MPI SPECT scans. There were no studies available with CCTA as reference. Pooled sensitivity of MPI SPECT for CAD was 0.66 (95% CI 0.53 to 0.77), pooled specificity was 0.75 (95% CI 0.63 to 0.84) and the area under the curve (AUC) was 0.76. Positive likelihood ratio was 2.50 (95% CI 1.78 to 3.51) and negative likelihood ratio was 0.41 (95% CI 0.28 to 0.61). Pooled positive predictive value was 64.9% and pooled negative predictive value was 74.1%. Significant heterogeneity existed across the included studies. Conclusions MPI SPECT had a moderate diagnostic accuracy in patients evaluated for kidney transplantation, with a high rate of false-negative findings. The use of an anatomical gold standard against a functional imaging test in the included studies is however suboptimal.
引用
收藏
页码:3405 / 3415
页数:11
相关论文
共 50 条
  • [1] Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis
    Jeroen R. Kelderman
    Floris E. J. Jolink
    Stan Benjamens
    Andrea G. Monroy-Gonzalez
    Robert A. Pol
    Riemer H. J. A. Slart
    Journal of Nuclear Cardiology, 2022, 29 : 3405 - 3415
  • [2] Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis
    de Jong, Marcus C.
    Genders, Tessa S. S.
    van Geuns, Robert-Jan
    Moelker, Adriaan
    Hunink, M. G. Myriam
    EUROPEAN RADIOLOGY, 2012, 22 (09) : 1881 - 1895
  • [3] Prognostic value of myocardial perfusion imaging in patients with chronic kidney disease: A systematic review and meta-analysis
    Cantoni, Valeria
    Green, Roberta
    Acampa, Wanda
    Assante, Roberta
    Zampella, Emilia
    Nappi, Carmela
    Gaudieri, Valeria
    Mannarino, Teresa
    D'Antonio, Adriana
    Petretta, Mario
    Cuocolo, Alberto
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (01) : 141 - 154
  • [4] Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis
    Marcus C. de Jong
    Tessa S. S. Genders
    Robert-Jan van Geuns
    Adriaan Moelker
    M. G. Myriam Hunink
    European Radiology, 2012, 22 : 1881 - 1895
  • [5] Diagnostic accuracy of static CT perfusion for the detection of myocardial ischemia. A systematic review and meta-analysis
    Sorgaard, Mathias Holm
    Kofoed, Klaus Fuglsang
    Linde, Jesper James
    George, Richard Thomas
    Rochitte, Carlos Eduardo
    Feuchtner, Gudrun
    Lima, Joao A. C.
    Abdulla, Jawdat
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (06) : 450 - 457
  • [6] Diagnostic Effect of Attenuation Correction in Myocardial Perfusion Imaging in Different Coronary Arteries: A Systematic Review and Meta-Analysis
    Huang, Jei-Yie
    Huang, Chun-Kai
    Yen, Ruoh-Fang
    Chien, Kuo-Liong
    Wu, Yen-Wen
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [7] Prognostic value of myocardial perfusion imaging in patients with chronic kidney disease: A systematic review and meta-analysis
    Valeria Cantoni
    Roberta Green
    Wanda Acampa
    Roberta Assante
    Emilia Zampella
    Carmela Nappi
    Valeria Gaudieri
    Teresa Mannarino
    Adriana D’Antonio
    Mario Petretta
    Alberto Cuocolo
    Journal of Nuclear Cardiology, 2022, 29 : 141 - 154
  • [8] Gender differences in the diagnostic accuracy of SPECT myocardial perfusion imaging: A bivariate meta-analysis
    Iskandar, Aline
    Limone, Brendan
    Parker, Matthew W.
    Perugini, Andrew
    Kim, Hyejin
    Jones, Charles
    Calamari, Brian
    Coleman, Craig I.
    Heller, Gary V.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (01) : 53 - 63
  • [9] Vasodilator Myocardial Perfusion Cardiac Magnetic Resonance Imaging Is Superior to Dobutamine Stress Echocardiography in the Detection of Relevant Coronary Artery Stenosis: A Systematic Review and Meta-Analysis on Their Diagnostic Accuracy
    Haberkorn, Sebastian M.
    Haberkorn, Sandra I.
    Bonner, Florian
    Kelm, Malte
    Hopkin, Gareth
    Petersen, Steffen E.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [10] Diagnostic Performance of Attenuation-Corrected Myocardial Perfusion Imaging for Coronary Artery Disease: A Systematic Review and Meta-Analysis
    Huang, Jei-Yie
    Huang, Chun-Kai
    Yen, Ruoh-Fang
    Wu, Hon-Yen
    Tu, Yu-Kang
    Cheng, Mei-Fang
    Lu, Ching-Chu
    Tzen, Kai-Yuan
    Chien, Kuo-Liong
    Wu, Yen-Wen
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (12) : 1893 - 1898