Monolithic versus conventional packed bed second stage regenerator evaluation in a Gifford-McMahon cryocooler

被引:5
作者
Wysokinski, TW [1 ]
Xu, XD
Barclay, JA
机构
[1] Univ Victoria, Cryofuel Syst Grp, Victoria, BC V8W 3P6, Canada
[2] Chinese Acad Sci, Cryogen Lab, Beijing 10080, Peoples R China
基金
加拿大自然科学与工程研究理事会;
关键词
monolithic; regenerator; GM cryocooler; load map;
D O I
10.1016/S0011-2275(02)00137-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work focuses on evaluation of the performance of a monolithic, versus standard packed bed, second stage regenerator in a Gifford-McMahon cryocooler. The monolithic, or bonded regenerator bed is made by means of a low temperature epoxy bonding technique developed [Adv. Cryog. Eng. 43B (1998) 1597] and optimized [R. Williamson, Individual Project Report, CFS, University of Victoria, 2001] by the Cryofuel Systems Group (CFS). Regenerator properties and results of several detailed load and no-load tests of the conventional packed bed regenerator and its monolithic form, using two different first stage regenerators, are presented. The monolithic regenerator performs as well as the standard one, despite a slightly higher-pressure drop observed. Analysis of this phenomenon is presented. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:691 / 696
页数:6
相关论文
empty
未找到相关数据