Safety Huddle Intervention for Reducing Physiologic Monitor Alarms: A Hybrid Effectiveness-Implementation Cluster Randomized Trial

被引:13
作者
Bonafide, Christopher P. [1 ,2 ,3 ,4 ]
Localio, A. Russell [5 ]
Stemler, Shannon [1 ,3 ,6 ]
Ahumada, Luis [7 ]
Dewan, Maya [8 ]
Ely, Elizabeth [9 ]
Keren, Ron [1 ,2 ,3 ,4 ]
机构
[1] Childrens Hosp Philadelphia, Div Gen Pediat, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Pediat, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Childrens Hosp Philadelphia, Ctr Pediat Clin Effectiveness, Philadelphia, PA 19104 USA
[4] Univ Penn, Leonard Davis Inst Hlth Econ, Philadelphia, PA 19104 USA
[5] Univ Penn, Dept Biostat & Epidemiol, Perelman Sch Med, Philadelphia, PA 19104 USA
[6] Univ Penn, Sch Nursing, Philadelphia, PA 19104 USA
[7] Childrens Hosp Philadelphia, Enterprise Analyt & Reporting, Philadelphia, PA 19104 USA
[8] Cincinnati Childrens Hosp Med Ctr, Div Crit Care Med, Cincinnati, OH 45229 USA
[9] Childrens Hosp Philadelphia, Dept Nursing, Philadelphia, PA 19104 USA
关键词
SITUATION AWARENESS; RESPONSE-TIME; ASSOCIATION; TELEMETRY; RATES;
D O I
10.12788/jhm.2956
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Monitor alarms occur frequently but rarely warrant intervention. OBJECTIVE: This study aimed to determine if a safety huddle-based intervention reduces unit-level alarm rates or alarm rates of individual patients whose alarms are discussed, as well as evaluate implementation outcomes. DESIGN: Unit-level, cluster randomized, hybrid effectiveness-implementation trial with a secondary patient-level analysis. SETTING: Children's hospital. PATIENTS: Unit-level: all patients hospitalized on four control (n = 4177) and four intervention (n = 7131) units between June 15, 2015 and May 8, 2016. Patient-level: 425 patients on randomly selected dates postimplementation. INTERVENTION: Structured safety huddle review of alarm data from the patients on each unit with the most alarms, with a discussion of ways to reduce alarms. MEASUREMENTS: Unit-level: change in unit-level alarm rates between baseline and postimplementation periods in intervention versus control units. Patient-level: change in individual patients' alarm rates between the 24 hours leading up to huddles and the 24 hours after huddles in patients who were discussed versus not discussed in huddles. RESULTS: Alarm data informed 580 huddle discussions. In unit-level analysis, intervention units had 2 fewer alarms/patient-day (95% CI: 7 fewer to 6 more, P = .50) compared with control units. In patient-level analysis, patients discussed in huddles had 97 fewer alarms/patientday (95% CI: 52-138 fewer, P < .001) in the posthuddle period compared with patients not discussed in huddles. Implementation outcome analysis revealed a low intervention dose of 0.85 patients/unit/day. CONCLUSIONS: Safety huddle-based alarm discussions did not influence unit-level alarm rates due to low intervention dose but were effective in reducing alarms for individual children. (C) 2018 Society of Hospital Medicine
引用
收藏
页码:609 / 615
页数:7
相关论文
共 23 条
[1]  
Allen J.D., 2012, Dissemination and implementation research in health: Translating science to practice, P281, DOI 10.1093/acprof:oso/9780199751877.003.0014
[2]  
[Anonymous], J INT CARE SOC
[3]   Reductions in Telemetry Order Duration Do Not Reduce Telemetry Utilization [J].
Boggan, Joel C. ;
Navar-Boggan, Ann Marie ;
Patel, Vaishali ;
Schulteis, Ryan D. ;
Simel, David L. .
JOURNAL OF HOSPITAL MEDICINE, 2014, 9 (12) :795-796
[4]   Video Analysis of Factors Associated With Response Time to Physiologic Monitor Alarms in a Children's Hospital [J].
Bonafide, Christopher P. ;
Localio, Russell ;
Holmes, John H. ;
Nadkarni, Vinay M. ;
Stemler, Shannon ;
MacMurchy, Matthew ;
Zander, Miriam ;
Roberts, Kathryn E. ;
Lin, Richard ;
Keren, Ron .
JAMA PEDIATRICS, 2017, 171 (06) :524-531
[5]   Association between exposure to nonactionable physiologic monitor alarms and response time in a children's hospital [J].
Bonafide, Christopher P. ;
Lin, Richard ;
Zander, Miriam ;
Graham, Christian Sarkis ;
Paine, Christine W. ;
Rock, Whitney ;
Rich, Andrew ;
Roberts, Kathryn E. ;
Fortino, Margaret ;
Nadkarni, Vinay M. ;
Localio, A. Russell ;
Keren, Ron .
JOURNAL OF HOSPITAL MEDICINE, 2015, 10 (06) :345-351
[6]   Improving Situation Awareness to Reduce Unrecognized Clinical Deterioration and Serious Safety Events [J].
Brady, Patrick W. ;
Muething, Stephen ;
Kotagal, Uma ;
Ashby, Marshall ;
Gallagher, Regan ;
Hall, Dawn ;
Goodfriend, Marty ;
White, Christine ;
Bracke, Tracey M. ;
DeCastro, Victoria ;
Geiser, Maria ;
Simon, Jodi ;
Tucker, Karen M. ;
Olivea, Jason ;
Conway, Patrick H. ;
Wheeler, Derek S. .
PEDIATRICS, 2013, 131 (01) :E298-E308
[7]   Redesigning Hospital Alarms for Patient Safety Alarmed and Potentially Dangerous [J].
Chopra, Vineet ;
McMahon, Laurence F., Jr. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (12) :1199-1200
[8]   Effectiveness-implementation Hybrid Designs Combining Elements of Clinical Effectiveness and Implementation Research to Enhance Public Health Impact [J].
Curran, Geoffrey M. ;
Bauer, Mark ;
Mittman, Brian ;
Pyne, Jeffrey M. ;
Stetler, Cheryl .
MEDICAL CARE, 2012, 50 (03) :217-226
[9]   Customizing alarm limits based on specific needs of patients [J].
Cvach M. ;
Kitchens M. ;
Smith K. ;
Harris P. ;
Flack M.N. .
Biomedical Instrumentation and Technology, 2017, 51 (03) :227-234
[10]   Fostering implementation of health services research findings into practice: a consolidated framework for advancing implementation science [J].
Damschroder, Laura J. ;
Aron, David C. ;
Keith, Rosalind E. ;
Kirsh, Susan R. ;
Alexander, Jeffery A. ;
Lowery, Julie C. .
IMPLEMENTATION SCIENCE, 2009, 4