Failure mechanism and bearing capacity of cold-formed steel trusses with HRC connectors

被引:42
作者
Mathieson, Chris [1 ]
Roy, Krishanu [2 ]
Clifton, G. Charles [2 ]
Ahmadi, Amin [2 ]
Lim, James B. P. [2 ]
机构
[1] Holmes Consulting LP, Auckland, New Zealand
[2] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
关键词
Cold-formed steel; Novel connection; Pinned joint; HRC; Truss; OPTIMAL-DESIGN;
D O I
10.1016/j.engstruct.2019.109741
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Portal frame structures, made up of cold-formed steel (CFS) trusses, are increasingly being used for lightweight building construction. There are different types of connectors available to assemble CFS trusses, which include CFS self-drilling screws, bolts and nails. Recently, a novel pin-jointed connector, called the Howick Rivet Connector (HRC), was developed and tested in T-joints to determine its reliable strength, stiffness and moment resisting capacity. The results from T-joint testing provided a background to the performance and reliable capacity of the HRC in shear. This paper focuses on the application of the HRC in a truss configuration. Four-point loading and cyclic tests were conducted on 26 specimens, which include two different thicknesses and two different cross-sections of channel sections to make the truss assembly. The HRC was used to provide a pinned connection between CFS channel sections through their flanges. The effects of number of HRCs, screws, bolts and washers were also tested in the experimental investigation. Both concentric and eccentric loadings were applied. All HRCs used in the trusses were 12.7 x 0.95 mm because of the availability of this tube size; except for trusses with 90 x 40 mm members connected with Tek screws. Interactions between the connection and connecting elements were examined closely. The main failure mechanisms for the trusses were bearing and rivet shear of the critical connections and buckling of the compression web member due to concentrated actions. The tests with 0.75 mm thick members failed in bearing unless washers were provided; in which case, they failed in rivet shear. However, for 0.95 mm thick members, the shear failure of rivet was observed, unless bolts were inserted; here, bearing failure occurred.
引用
收藏
页数:19
相关论文
共 17 条
[1]   An experimental study on a novel cold-formed steel connection for light gauge open channel steel trusses [J].
Ahmadi, Amin ;
Mathieson, Chris ;
Clifton, G. Charles ;
Das, Raj ;
Lim, James B. P. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 :70-79
[2]  
American Iron and Steel Institute, 2016, S100 AM IR STEEL I N
[3]  
[Anonymous], 2018, AS/NZ 4600.
[4]  
[Anonymous], 2006, 199313 EN
[5]   Finite element investigation on the structural behaviour of cold-formed steel bolted connections [J].
Chung, KF ;
Ip, KH .
ENGINEERING STRUCTURES, 2001, 23 (09) :1115-1125
[6]   Development of a New Cold-Formed Steel Building System [J].
Darcy, Greg ;
Mahendran, Mahen .
ADVANCES IN STRUCTURAL ENGINEERING, 2008, 11 (06) :661-677
[7]   Strength and behaviour of cold-formed steel offset trusses [J].
Dawe, J. L. ;
Liu, Yi ;
Li, J. Y. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (04) :556-565
[8]   Cold-formed steel structures [J].
Hancock, GJ .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (04) :473-487
[9]   The behaviour of a new type of connection system for light-weight steel structures applied to roof trusses [J].
Kaitila, Olli ;
Kesti, Jyrki ;
Makelainen, Pentti .
STEEL AND COMPOSITE STRUCTURES, 2001, 1 (01) :17-32
[10]   Finite element idealization of a cold-formed steel portal frame [J].
Lim, JBP ;
Nethercot, DA .
JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (01) :78-94