A new Method for Cupping and Scatter Precorrection for Flat Detector CT

被引:2
作者
Grimmer, Rainer [1 ]
Maass, Clemens [1 ]
Kachelriess, Marc [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
来源
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2009年
关键词
Computed tomography (CT); beam hardening; scatter; cupping; image correction;
D O I
10.1109/NSSMIC.2009.5401805
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Scatter and beam hardening are prominent artifacts in x-ray CT. Currently, there is no precorrection method that inherently accounts for tube voltage modulation and shaped prefiltration. We generalized a method for self-calibration based on binary tomography of homogeneous objects [1] to use this information to preprocess scans of other, non-binary objects, e.g. to reduce artifacts in medical CT applications. Further on we extended the method to handle not only beam hardening but also scatter and to allow for detector pixel-specific precorrections. This implies that our calibration technique handles varying tube voltage and shaped prefiltration. We propose a method that models the beam hardening correction by using a rational function while the scatter component is modeled using the pep-model. A smoothness constraint is applied to the parameter space to regularize the underdetermined system of non-linear equations. The parameters determined are then used to precorrect CT scans. Our algorithm was evaluated using simulated data of a flat panel cone-beam CT scanner with tube voltage variation and bow-tie prefiltration and real data of a flat detector cone-beam CT scanner. In simulation studies our correction model proved to be nearly perfect and the algorithm showed its abilities by correcting the beam hardening and scatter effects. Reconstructions of measured data showed significantly less artifacts than the standard reconstruction.
引用
收藏
页码:3517 / 3522
页数:6
相关论文
共 10 条
[1]  
[Anonymous], 2007, NUMERICAL RECIPES
[2]   BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) :390-398
[3]   An iterative approach to the beam hardening correction in cone beam CT [J].
Hsieh, J ;
Molthen, RC ;
Dawson, CA ;
Johnson, RH .
MEDICAL PHYSICS, 2000, 27 (01) :23-29
[4]   METHOD FOR CORRECTING BONE INDUCED ARTIFACTS IN COMPUTED TOMOGRAPHY SCANNERS [J].
JOSEPH, PM ;
SPITAL, RD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (01) :100-108
[5]   Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography [J].
Kachelriess, M ;
Sourbelle, K ;
Kalender, WA .
MEDICAL PHYSICS, 2006, 33 (05) :1269-1274
[6]   Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT [J].
Kyriakou, Yiannis ;
Riedel, Thomas ;
Kalender, Willi A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (18) :4567-4586
[7]   A novel beam hardening correction method for computed tomography [J].
Li, Baolei ;
Zhang, Quanhong ;
Li, Junjiang .
2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, :891-895
[8]   Reduction of beam-hardening artifacts in X-ray CT [J].
Menvielle, Nathalie ;
Goussard, Yves ;
Orban, Dominique ;
Soulez, Gilles .
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, :1865-1868
[9]   Efficient object scatter correction algorithm for third and fourth generation CT scanners [J].
Ohnesorge, B ;
Flohr, T ;
Klingenbeck-Regn, K .
EUROPEAN RADIOLOGY, 1999, 9 (03) :563-569
[10]   SEMIEMPIRICAL MODEL FOR GENERATING TUNGSTEN TARGET X-RAY-SPECTRA [J].
TUCKER, DM ;
BARNES, GT ;
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1991, 18 (02) :211-218