Effect of Molar Preparation Axial Height on Retention of Adhesively-luted CAD-CAM Ceramic Crowns

被引:8
作者
Wake, Robert [1 ]
Buck, Richard [2 ]
DuVall, Nicholas [3 ]
Roberts, Howard [4 ]
机构
[1] 18th Dent Squadron, Kadena Air Base, Japan
[2] 633 Dent Squadron, Joint Base Langley Eusti, VA USA
[3] 96th Dent Squadron, Eglin AFB, FL USA
[4] Univ Kentucky, Coll Dent, Lexington, KY USA
关键词
CAD-CAM; adhesion; lithium disilicate; failure load; axial wall height; total occlusal convergence; PERSPECTIVES; RESISTANCE;
D O I
10.3290/j.jad.a43651
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the effect of axial wall height (AWH) on failure resistance of CAD-CAM adhesively-bonded, allceramic crowns on molar preparations with a conservative total occlusal convergence (TOC). Materials and Methods: 60 newly extracted maxillary third molars were divided into 5 groups (n = 12) and prepared for all-ceramic crowns with occlusal cervical AWH of 0, 1, 2, 3, and 4 mm, all containing a conservative 10-degree TOC. Scanned preparations were fitted with lithium-disilicate glass-ceramic crowns using a self-adhesive resin-composite luting agent after intaglio surface preparation with hydrofluoric acid and silane. Specimens were stored at 37 degrees C/98% humidity for 24 h and tested to failure at a 45-degree angle applied to the palatal cusp on a universal testing machine. Mean results were analyzed using ANOVA and Tukey's test (p = 0.05). Results: Preparations containing 2, 3, and 4 mm AWH demonstrated similar and higher failure resistance than the 0- and 1-mm axial wall height groups. Conclusions: Under the conditions of this study, evidence is presented that under certain conditions CAD-CAM adhesive technology may compensate for less than optimal AWH. Based on both failure load results and failure mode analysis, adhesively-luted maxillary molar CAD-CAM crowns based on a preparation containing 10-degree TOC require at least 2 mm AWH for adequate resistance and retention. However, adoption of these findings is cautioned until both fatigue analysis and appropriate clinical evidence has been provided.
引用
收藏
页码:545 / 550
页数:6
相关论文
共 18 条
[1]   Fatigue testing of biomaterials and their interfaces [J].
Arola, Dwayne .
DENTAL MATERIALS, 2017, 33 (04) :367-381
[2]  
Bernal G, 1993, Int J Prosthodont, V6, P286
[3]  
Bindl A, 2005, INT J PROSTHODONT, V18, P219
[4]   The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses [J].
Chen, Chenfeng ;
Trindade, Flavia Zardo ;
de Jager, Niek ;
Kleverlaan, Cornelis J. ;
Feilzer, Albert J. .
DENTAL MATERIALS, 2014, 30 (09) :954-962
[5]   Retention of metal ceramic crowns cemented with resin cements: Effects of preparation taper and height [J].
ElMowafy, OM ;
Fenton, AH ;
Forrester, N ;
Milenkovic, M .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (05) :524-529
[6]  
Friedlander L D, 1990, Int J Prosthodont, V3, P159
[7]   Thermal cycling procedures for laboratory testing of dental restorations [J].
Gale, MS ;
Darvell, BW .
JOURNAL OF DENTISTRY, 1999, 27 (02) :89-99
[8]   FUNDAMENTALS OF EXTRACORONAL TOOTH PREPARATION .1. RETENTION AND RESISTANCE FORM [J].
GILBOE, DB ;
TETERUCK, WR .
JOURNAL OF PROSTHETIC DENTISTRY, 1974, 32 (06) :651-656
[9]  
Goodacre C.J., 2004, Dental Clinics of North America, V48, P359, DOI DOI 10.1016/J.CDEN.2003.12.015
[10]   Tooth preparations for complete crowns: An art form based on scientific principles [J].
Goodacre, CJ ;
Campagni, WV ;
Aquilino, SA .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (04) :363-376