Deep learning via ECG and PPG signals for prediction of depth of anesthesia

被引:26
作者
Chowdhury, Meghna Roy [1 ]
Madanu, Ravichandra [2 ]
Abbod, Maysam F. [3 ]
Fan, Shou-Zen [4 ]
Shieh, Jiann-Shing [2 ]
机构
[1] Vellore Inst Technol, Dept Elect & Commun Engn, Chennai 600127, Tamil Nadu, India
[2] Yuan Ze Univ, Dept Mech Engn, Taoyuan 32003, Taiwan
[3] Brunel Univ London, Dept Elect & Comp Engn, Uxbridge UB8 3PH, Middx, England
[4] Natl Taiwan Univ, Coll Med, Dept Anesthesiol, Taipei 100, Taiwan
关键词
Electrocardiogram (ECG); Photoplethysmography (PPG); Bispectral index (BIS); Convolutional neural network (CNN); Depth of anesthesia (DoA); BISPECTRAL INDEX; EEG SIGNALS; PROPOFOL; AWARENESS;
D O I
10.1016/j.bspc.2021.102663
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During surgeries, the amount of used anesthetic depends on the physical conditions of the patient and is immensely critical. The conventionally used BIS Quantro machine which measures the Bispectral Index (BIS) level in order to help doctors administer anesthesia, is quite expensive. In this paper, an economic, accurate and state-of-the-art technique is presented to predict the depth of anesthesia (DoA) via advanced deep learning models using 512 Hz Electrocardiogram (ECG) and 128 Hz Photoplethysmography (PPG). The study is conducted based on signal collected from 50 patients acquired during surgery at National Taiwan University Hospital (NTUH). First, heatmaps of the ECG and PPG signals (individual and combined subplots) are generated using MATLAB by filtering 5 s windows to match the frequency of the BIS Quantro Machine which is 0.2 Hz. Then, various deep learning models comprising 5, 6, 8, 10 and 19 layered CNNs are trained using data of 40 patients and tested using the remaining 10 patients. The heatmap images of ECG and PPG are fed as inputs to the CNN models separately and using two input channels. The best accuracy achieved is 86 % which is attained using 10 layered CNN with Tensorflow backend, with combined ECG and PPG heatmaps as inputs. This study uses inexpensive signals, minimum data reconstruction, minimum memory and timing constrains to achieve a decent accuracy, and so it can be used by even small hospitals.
引用
收藏
页数:12
相关论文
共 48 条
[11]  
Dou L, 2014, WORLD J EMERG MED, V5, P53, DOI [10.5847/wjem.j.issn.1920-8642.2014.01.009, 10.5847/wjem.j.1920-8642.2014.01.009]
[12]   On the Analysis of Fingertip Photoplethysmogram Signals [J].
Elgendi, Mohamed .
CURRENT CARDIOLOGY REVIEWS, 2012, 8 (01) :14-25
[13]   Influence of nociceptive stimulation on analgesia nociception index (ANI) during propofol-remifentanil anaesthesia [J].
Gruenewald, M. ;
Ilies, C. ;
Herz, J. ;
Schoenherr, T. ;
Fudickar, A. ;
Hoecker, J. ;
Bein, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (06) :1024-1030
[14]   Recent advances in convolutional neural networks [J].
Gu, Jiuxiang ;
Wang, Zhenhua ;
Kuen, Jason ;
Ma, Lianyang ;
Shahroudy, Amir ;
Shuai, Bing ;
Liu, Ting ;
Wang, Xingxing ;
Wang, Gang ;
Cai, Jianfei ;
Chen, Tsuhan .
PATTERN RECOGNITION, 2018, 77 :354-377
[15]   Cardiologist-level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural network [J].
Hannun, Awni Y. ;
Rajpurkar, Pranav ;
Haghpanahi, Masoumeh ;
Tison, Geoffrey H. ;
Bourn, Codie ;
Turakhia, Mintu P. ;
Ng, Andrew Y. .
NATURE MEDICINE, 2019, 25 (01) :65-+
[16]   Photoplethysmographic and pulse pressure variations during abdominal surgery [J].
Hoiseth, L. O. ;
Hoff, I. E. ;
Skare, O. ;
Kirkeboen, K. A. ;
Landsverk, S. A. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (10) :1221-1230
[17]   Propofol-nitrous oxide anesthesia enhances the heart rate response to intravenous isoproterenol infusion [J].
Horiguchi, T ;
Nishikawa, T .
ANESTHESIA AND ANALGESIA, 2003, 96 (01) :132-135
[18]   Heart rate response to intravenous atropine during propofol anesthesia [J].
Horiguchi, T ;
Nishikawa, T .
ANESTHESIA AND ANALGESIA, 2002, 95 (02) :389-392
[19]   Using a short-term parameter of heart rate variability to distinguish awake from isoflurane anesthetic states [J].
Huang, Hui-Hsun ;
Lee, Yi-Hui ;
Chan, Hsiao-Lung ;
Wang, Yong-Ping ;
Huang, Chi-Hsiang ;
Fan, Shou-Zen .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (10) :977-984
[20]   Assessment of surgical stress during general anaesthesia [J].
Huiku, M. ;
Uutela, K. ;
van Gils, M. ;
Korhonen, I. ;
Kymalainen, M. ;
Merilainen, P. ;
Paloheimo, M. ;
Rantanen, M. ;
Takala, P. ;
Viertio-Oja, H. ;
Yli-Hankala, A. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (04) :447-455