Stress distribution in the supraspinatus tendon after tendon repair - Suture anchors versus transosseous suture fixation

被引:54
|
作者
Sano, Hirotaka
Yamashita, Takeshi
Wakabayashi, Ikuko
Itoi, Eiji
机构
[1] Tohoku Univ, Sch Med, Dept Orthopaed Surg, Sendai, Miyagi 980, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Mat Proc, Sendai, Miyagi 980, Japan
[3] Akitaken Taiheirouikuen Hosp Disabled Children, Dept Orthopaed Surg, Akita, Japan
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2007年 / 35卷 / 04期
关键词
finite element method; stress concentration; rotator cuff repair; rerupture; single-row fixation; double-row fixation; transosseous suture fixation;
D O I
10.1177/0363546506296310
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The stress concentration at the site of supraspinatus tendon repair, either by suture anchor fixation or by transosseous suture fixation, has not been fully clarified. Hypothesis: Suture anchor fixation showed higher stress concentrations in the tendon than did transosseous suture fixation. Study Design: Controlled laboratory study. Methods: Three finite element models were developed based on a previously published model of normal supraspinatus tendon (0 degrees abduction). Single-row fixation, double-row fixation, and transosseous suture fixation were simulated. A tensile force was applied to the proximal end of the supraspinatus tendon to simulate its contraction force. Results: In the single-row model, the stress appeared from the site of the anchor and extended into the proximal tendon. The highest stress concentration was observed on the bursal surface of the tendon. The double-row model showed a similar pattern to the single-row model except that the stress concentration was observed only around the medial anchor. In the transosseous model, the stress appeared from the attachment site to a bony trough, which extended proximally into the tendon substance. No significant stress concentration was observed inside the tendon. Conclusion: Both single-row and double-row fixations showed higher stress concentration inside the tendon than did transosseous suture fixation. Clinical Relevance: A high stress concentration might be a cause of the rerupture often observed after arthroscopic cuff repair using suture anchors.
引用
收藏
页码:542 / 546
页数:5
相关论文
共 50 条
  • [21] Biomechanical evaluation of augmentation of suture-bridge supraspinatus repair with additional anterior fixation
    Garcia, Ivan A.
    Jain, Nickul S.
    McGarry, Michelle H.
    Tibone, James E.
    Lee, Thay Q.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (07) : E13 - E18
  • [22] Tendon-grasping strength of various suture configurations for rotator cuff repair
    Onur Hapa
    F. Alan Barber
    Emin Sünbüloğlu
    Yavuz Kocabey
    Nazlı Sarkalkan
    Gökhan Baysal
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1749 - 1754
  • [23] Tendon-grasping strength of various suture configurations for rotator cuff repair
    Hapa, Onur
    Barber, F. Alan
    Sunbuloglu, Emin
    Kocabey, Yavuz
    Sarkalkan, Nazli
    Baysal, Gokhan
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (10) : 1749 - 1754
  • [24] Bamboo-inspired lightweight tape suture with hollow and porous structure for tendon repair
    Zhang, Qian
    Mao, Jifu
    Li, Chaojing
    Han, Hui
    Lin, Jing
    Wang, Fujun
    Wang, Lu
    MATERIALS & DESIGN, 2020, 193
  • [25] Biomechanical comparisons of three minimally invasive Achilles tendon percutaneous repair suture techniques
    Melcher, C.
    Renner, C.
    Piepenbrink, M.
    Fischer, N.
    Buettner, A.
    Wegener, V.
    Birkenmaier, C.
    Jansson, V.
    Wegener, B.
    CLINICAL BIOMECHANICS, 2022, 92
  • [26] Functional outcomes and repair integrity after arthroscopic repair of partial articular supraspinatus tendon avulsion
    Castricini, Roberto
    La Camera, Francesco
    De Gori, Marco
    Orlando, Nicola
    De Benedetto, Massimo
    Galasso, Olimpio
    Gasparini, Giorgio
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (03) : 369 - 375
  • [27] Biomechanical comparison of double-loaded suture anchors using arthroscopic Mason-Allen Stitches versus traditional transosseous suture technique and modified Mason-Allen stitches for rotator cuff repair
    Klinger, Hans-Michael
    Steckel, Hanno
    Spahn, Gunter
    Buchhorn, Gottfried H.
    Baums, Mike H.
    CLINICAL BIOMECHANICS, 2007, 22 (01) : 106 - 111
  • [28] Arthroscopic Single-Row Modified Mason-Allen Repair Versus Double-Row Suture Bridge Reconstruction for Supraspinatus Tendon Tears A Matched-Pair Analysis
    Gerhardt, Christian
    Hug, Konstantin
    Pauly, Stephan
    Marnitz, Tim
    Scheibel, Markus
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (12): : 2777 - 2785
  • [29] Optimized design of an enthesis-mimicking suture anchor-tendon hybrid graft for mechanically robust bone-tendon repair
    Wang, Chenyang
    Zhang, Xu
    Wang, Dan Michelle
    Yung, Patrick S. H.
    Tuan, Rocky S.
    Ker, Dai Fei Elmer
    ACTA BIOMATERIALIA, 2024, 176 : 277 - 292
  • [30] Safety evaluation of a laxity-minimizing suture at 5 days and 6 weeks after repair of a sheep infraspinatus tendon
    Favorito, Paul J.
    Spenciner, David B.
    Muench, Timothy R.
    Bartrom, Jolee
    Ryu, Richard K.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (01) : 164 - 169