Modern Trunnions Are More Flexible: A Mechanical Analysis of THA Taper Designs

被引:78
作者
Porter, David A. [1 ]
Urban, Robert M. [2 ]
Jacobs, Joshua J. [2 ]
Gilbert, Jeremy L. [3 ]
Rodriguez, Jose A. [1 ]
Cooper, H. John [1 ]
机构
[1] Lenox Hill Hosp, Dept Orthopaed Surg, New York, NY 10024 USA
[2] Rush Univ Med Ctr, Dept Orthopaed Surg, Chicago, IL USA
[3] Syracuse Univ, Dept Biomed & Chem Engn, Syracuse, NY USA
关键词
TOTAL HIP-ARTHROPLASTY; HEAD-NECK TAPER; FRETTING CORROSION; CREVICE CORROSION; FEMORAL STEMS; METAL RELEASE; INTERFACE; PROSTHESES; POLYETHYLENE; REPLACEMENTS;
D O I
10.1007/s11999-014-3965-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background There is renewed concern surrounding the potential for corrosion at the modular head-neck junction to cause early failure in contemporary THAs. Although taper corrosion involves a complex interplay of many factors, a previous study suggested that a decrease in flexural rigidity of the femoral trunnion may be associated with an increased likelihood of corrosion at retrieval. Questions/purposes By analyzing a large revision retrieval database of femoral stems released during a span of three decades, we asked: (1) how much does flexural rigidity vary among different taper designs; (2) what is the contribution of taper geometry alone to flexural rigidity of the femoral trunnion; and (3) how have flexural rigidity and taper length changed with time in this group of revised retrievals? Methods A dual-center retrieval analysis of 85 modular femoral stems released between 1983 and 2012 was performed, and the flexural rigidity and length of the femoral trunnions were determined. These stems were implanted between 1991 and 2012 and retrieved at revision or removal surgery between 2004 and 2012. There were 10 different taper designs made from five different metal alloys from 16 manufacturers. Digital calipers were used to measure taper geometries by two independent observers. Results Median flexural rigidity was 228 N-m(2); however, there was a wide range of values among the various stems spanning nearly an order of magnitude between the most flexible (80 N-m(2)) and most rigid (623 N-m(2)) trunnions, which was partly attributable to the taper geometry and to the material properties of the base alloy. There was a negative correlation between flexural rigidity and length of the trunnion and release date of the stem. Conclusions There is wide variability in flexural rigidity of various taper designs, with a trend toward trunnions becoming shorter and less rigid with time.
引用
收藏
页码:3963 / 3970
页数:8
相关论文
共 39 条
[11]   Pseudotumour Formation Due to Tribocorrosion at the Taper Interface of Large Diameter Metal on Polymer Modular Total Hip Replacements [J].
Cook, Richard B. ;
Bolland, Benjamin J. R. F. ;
Wharton, Julian A. ;
Tilley, Simon ;
Latham, Jeremy M. ;
Wood, Robert J. K. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :1430-1436
[12]   CORROSION AND WEAR AT THE MODULAR INTERFACE OF UNCEMENTED FEMORAL STEMS [J].
COOK, SD ;
BARRACK, RL ;
CLEMOW, AJT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :68-72
[13]  
COOK SD, 1994, CLIN ORTHOP RELAT R, P80
[14]   Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip Arthroplasty [J].
Cooper, H. John ;
Della Valle, Craig J. ;
Berger, Richard A. ;
Tetreault, Matthew ;
Paprosky, Wayne G. ;
Sporer, Scott M. ;
Jacobs, Joshua J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (18) :1655-1661
[15]  
Cooper JH., 2012, Semin Arthroplasty, V23, P273, DOI DOI 10.1053/J.SART.2013.01.013
[16]   The Influence of Head Size on Corrosion and Fretting Behaviour at the Head-Neck Interface of Artificial Hip Joints [J].
Dyrkacz, Richard M. R. ;
Brandt, Jan-M. ;
Ojo, Olanrewaju A. ;
Turgeon, Thomas R. ;
Wyss, Urs P. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (06) :1036-1040
[17]   Ti based biomaterials, the ultimate choice for orthopaedic implants - A review [J].
Geetha, M. ;
Singh, A. K. ;
Asokamani, R. ;
Gogia, A. K. .
PROGRESS IN MATERIALS SCIENCE, 2009, 54 (03) :397-425
[18]  
Gilbert J.L., 2012, DEGRADATION IMPLANT, P1, DOI [10.1007/978-1-4614-3942-4_1, DOI 10.1007/978-1-4614-3942-4_1]
[19]   Fretting Crevice Corrosion of Stainless Steel Stem-CoCr Femoral Head Connections: Comparisons of Materials, Initial Moisture, and Offset Length [J].
Gilbert, Jeremy L. ;
Mehta, Manav ;
Pinder, Bryan .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (01) :162-173
[20]   IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING [J].
GILBERT, JL ;
BUCKLEY, CA ;
JACOBS, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12) :1533-1544