CNAP - EVOLUTION OF CONTINUOUS NON-INVASIVE ARTERIAL BLOOD PRESSURE MONITORING

被引:0
作者
Fortin, J. [1 ]
Wellisch, A. [1 ]
Maier, K. [1 ]
机构
[1] CNSyst Med Tech AG, Reininghausstr 13, A-8020 Graz, Austria
来源
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK | 2013年 / 58卷
关键词
Continuous; non-invasive; blood pressure;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood pressure (BP) is one of the most important cardiovascular parameters in nearly every care area. A method for continuous non-invasive arterial pressure (CNAP) monitoring is described. CNAP is especially designed for perioperative, critical and emergency care. It concentrates on the clinically important BPinformation such as absolute BP and BP-changes as well as physiological BP-rhythms and BP-waveforms, where other hemodynamic parameters like cardiac output (CO) and dynamic fluid management parameters (e.g. pulse pressure variation PPV) can be derived. For this kind of hemodynamic information, tailor-made mechanisms have been developed. Recent validation studies underline accuracy and clinical acceptance of the CNAP technology.
引用
收藏
页数:2
相关论文
共 18 条
[1]   Continuous non-invasive arterial pressure measurement: Evaluation of CNAP™ device during vascular surgery [J].
Biais, M. ;
Vidil, L. ;
Roullet, S. ;
Masson, F. ;
Quinart, A. ;
Revel, P. ;
Sztark, F. .
ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2010, 29 (7-8) :530-535
[2]   The Ability of Pulse Pressure Variations Obtained with CNAP™ Device to Predict Fluid Responsiveness in the Operating Room [J].
Biais, Matthieu ;
Stecken, Laurent ;
Ottolenghi, Laetitia ;
Roullet, Stephanie ;
Quinart, Alice ;
Masson, Francoise ;
Sztark, Francois .
ANESTHESIA AND ANALGESIA, 2011, 113 (03) :523-528
[3]  
BOEHMER RD, 1987, J CLIN MONITOR, V3, P282
[4]   Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops [J].
Fortin, J. ;
Marte, W. ;
Grullenberger, R. ;
Hacker, A. ;
Habenbacher, W. ;
Heller, A. ;
Wagner, C. H. ;
Wach, P. ;
Skrabal, F. .
COMPUTERS IN BIOLOGY AND MEDICINE, 2006, 36 (09) :941-957
[5]  
Fortin J, 2011, US, Patent No. [2011/0105918, 20110105918]
[6]   Clinical validation of a continuous non-invasive haemodynamic monitor (CNAP 500) during general anaesthesia [J].
Hahn, R. ;
Rinoesl, H. ;
Neuner, M. ;
Kettner, S. C. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (04) :581-585
[7]   A Systematic Review and Meta-Analysis on the Use of Preemptive Hemodynamic Intervention to Improve Postoperative Outcomes in Moderate and High-Risk Surgical Patients [J].
Hamilton, Mark A. ;
Cecconi, Maurizio ;
Rhodes, Andrew .
ANESTHESIA AND ANALGESIA, 2011, 112 (06) :1392-1402
[8]   Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement [J].
Ilies, C. ;
Kiskalt, H. ;
Siedenhans, D. ;
Meybohm, P. ;
Steinfath, M. ;
Bein, B. ;
Hanss, R. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (03) :413-419
[9]   Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement [J].
Ilies, C. ;
Bauer, M. ;
Berg, P. ;
Rosenberg, J. ;
Hedderich, J. ;
Bein, B. ;
Hinz, J. ;
Hanss, R. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (02) :202-210
[10]  
IMHOLZ BPM, 1992, J HYPERTENS, V10, P979