Comparison of porcine and human lumbar spine flexion mechanics

被引:0
作者
Dickey, JP [1 ]
Dumas, GA
Bednar, DA
机构
[1] Univ Guelph, Dept Human Biol & Nutr Sci, Guelph, ON N1G 2W, Canada
[2] Queens Univ, Dept Mech Engn, Kingston, ON K7L 3N6, Canada
[3] McMaster Univ, Div Orthopaed Surg, Hamilton, ON L8S 4L8, Canada
关键词
biomechanics; animal model; porcine; human; comparative mechanics; spine; lumbar spine;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Animal models have been proposed as an alternative to human spinal specimens for in vitro mechanical testing due to the limited availability, poor reproducibility, high cost, and potential health risk associated with human specimens. The purpose of this study was to directly compare the flexion biomechanics of porcine and human lumbar spines. We determined the range of motion, laxity zone and the stiffness under pure-moment flexion loading. The porcine and human specimens showed qualitative similarities in mechanical behaviour. However the porcine specimens demonstrated a number of quantitative differences including a less-stiff, more extensive, low-stiffness region around the neutral position and a larger flexion range of motion. The results suggest that the porcine lumbar spine may be a potential model for the human lumbar spine for certain in vitro mechanical tests including comparisons between spinal fixation constructs.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 52 条
  • [21] JIANG HX, 1995, J ANAT, V187, P85
  • [22] Comparison between sheep and human cervical spines -: An anatomic, radiographic, bone mineral density, and biomechanical study
    Kandziora, F
    Pflugmacher, R
    Scholz, M
    Schnake, K
    Lucke, M
    Schröder, R
    Mittlmeier, T
    [J]. SPINE, 2001, 26 (09) : 1028 - 1037
  • [23] Effects of specimen length on the monosegmental motion behavior of the lumbar spine
    Kettler, A
    Wilke, HJ
    Haid, C
    Claes, L
    [J]. SPINE, 2000, 25 (05) : 543 - 550
  • [24] Kumar N, 2000, ANAT RECORD, V260, P189, DOI 10.1002/1097-0185(20001001)260:2<189::AID-AR80>3.0.CO
  • [25] 2-N
  • [26] Kumar N, 2002, ANAT REC, V266, P108
  • [27] A continuous pure moment loading apparatus for biomechanical testing of multi-segment spine specimens
    Lysack, JT
    Dickey, JP
    Dumas, GA
    Yen, D
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (06) : 765 - 770
  • [28] In vitro flexibility of an experimental pedicle screw and plate instrumentation system on the porcine lumbar spine
    Lysack, JT
    Yen, D
    Dumas, GA
    [J]. MEDICAL ENGINEERING & PHYSICS, 2000, 22 (07) : 461 - 468
  • [29] DISC DEGENERATION AFFECTS THE MULTIDIRECTIONAL FLEXIBILITY OF THE LUMBAR SPINE
    MIMURA, M
    PANJABI, MM
    OXLAND, TR
    CRISCO, JJ
    YAMAMOTO, I
    VASAVADA, A
    [J]. SPINE, 1994, 19 (12) : 1371 - 1380
  • [30] The relative importance of vertebral bone density and disc degeneration in spinal flexibility and interbody implant performance - An in vitro study
    Oxland, TR
    Lund, T
    Jost, B
    Cripton, P
    Lippuner, K
    Jaeger, P
    Nolte, LP
    [J]. SPINE, 1996, 21 (22) : 2558 - 2569