Percutaneous mechanical circulatory support. Options and importance

被引:0
作者
Seidler, T. [1 ]
机构
[1] Univ Med Gottingen, Abt Kardiol & Pneumol, D-37075 Gottingen, Germany
来源
INTERNIST | 2014年 / 55卷 / 11期
关键词
Shock; cardiogenic; Heart failure; Extracorporeal life support; Intra-aortic balloon pumping; RANDOMIZED CLINICAL-TRIAL; VENTRICULAR ASSIST DEVICE; INTRAAORTIC BALLOON PUMP; ACUTE MYOCARDIAL-INFARCTION; CORONARY INTERVENTION; CARDIOGENIC-SHOCK; HEMODYNAMIC SUPPORT; TASK-FORCE; EUROPEAN-SOCIETY; IMPELLA; 2.5;
D O I
10.1007/s00108-014-3505-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In cases of low cardiac output and chronic cardiac failure despite conventional therapy, mechanical circulatory support may be the only option to ensure adequate organ perfusion and to save the life of the patient. In recent years, several conceptionally different methods of circulatory support have been developed for percutaneous application in interventional cardiology and intensive care. Indications range from elective use in complex cardiac interventions to long-term support as a bridge to recovery. As intra-aortic balloon pump support can no longer be considered for routine use in ischemic cardiogenic shock, micro-axial pumps for extracorporeal membrane oxygenation and extracorporeal life support systems (ECMO/ECLS) gain attractiveness due to a more convincing impact on the hemodynamics. However, an increasing level of support is paralleled by greater invasiveness and complexity of the systems. Due to a lack of larger comparative trials, the benefits and risks of adverse events must be balanced against those of conventional therapy with inotropes and largely on an individual basis. This review summarizes the options for percutaneous circulatory support with special consideration to applications in the catheter laboratory and intensive care units in internal medicine.
引用
收藏
页码:1267 / +
页数:8
相关论文
共 25 条
[1]   ACC/AHA 2007 guide lines for the management of patients with unstable Angina/Non-ST-Elevation myocardial infraction - Executive summary [J].
Anderson, Jeffrey L. ;
Adams, Cynthia D. ;
Antman, Elliott M. ;
Bridges, Charles R. ;
Califf, Robert M. ;
Casey, Donald E., Jr. ;
Chavey, William E., II ;
Fesmire, Francis M. ;
Hochman, Judith S. ;
Levin, Thomas N. ;
Lincoff, A. Michael ;
Peterson, Eric D. ;
Theroux, Pierre ;
Wenger, Nanette Kass ;
Wright, R. Scott ;
Smith, Sidney C., Jr. ;
Jacobs, Alice K. ;
Adams, Cynthia D. ;
Riegel, Barbara .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (07) :652-726
[2]   Impella and Extracorporeal Membrane Oxygenation: A Demanding Combination [J].
Beurtheret, Sylvain ;
Mordant, Pierre ;
Pavie, Alain ;
Leprince, Pascal .
ASAIO JOURNAL, 2012, 58 (03) :291-293
[3]   The science behind percutaneous hemodynamic support: A review and comparison of support strategies [J].
Burkhoff, Daniel ;
Naidu, Srihari S. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (05) :816-829
[4]   Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trials [J].
Cheng, Jin M. ;
den Uil, Corstiaan A. ;
Hoeks, Sanne E. ;
van der Ent, Martin ;
Jewbali, Lucia S. D. ;
van Domburg, Ron T. ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2009, 30 (17) :2102-2108
[5]   A new right ventricular assist device for right ventricular support [J].
Christiansen, S ;
Brose, S ;
Demircan, L ;
Autschbach, R .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 24 (05) :834-836
[6]   Evaluating the learning curve in the prospective Randomized Clinical Trial of hemodynamic support with Impella 2.5 versus Intra-Aortic Balloon Pump in patients undergoing high-risk percutaneous coronary intervention: a prespecified subanalysis of the PROTECT II study [J].
Henriques, Jose P. S. ;
Ouweneel, Dagmar M. ;
Naidu, Srihari S. ;
Palacios, Igor F. ;
Popma, Jeffrey ;
Ohman, E. Magnus ;
O'Neill, William W. .
AMERICAN HEART JOURNAL, 2014, 167 (04) :472-U85
[7]   Outcome evaluation of the bridge to bridge concept in patients with cardiogenic shock [J].
Hoefer, Daniel ;
Ruttmann, Elfriede ;
Poelzl, Gerhard ;
Kilo, Juliane ;
Hoermann, Christoph ;
Margreiter, Raimund ;
Laufer, Guenther ;
Antretter, Herwig .
ANNALS OF THORACIC SURGERY, 2006, 82 (01) :28-34
[8]   The Percutaneous Ventricular Assist Device in Severe Refractory Cardiogenic Shock [J].
Kar, Biswajit ;
Gregoric, Igor D. ;
Basra, Sukhdeep S. ;
Idelchik, Gary M. ;
Loyalka, Pranav .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (06) :688-696
[9]  
Levine GN, 2011, CIRCULATION, V124, pE574, DOI 10.1161/CIR.0b013e31823ba622
[10]   ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012 The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association (HFA) of the ESC [J].
McMurray, John J. V. ;
Adamopoulos, Stamatis ;
Anker, Stefan D. ;
Auricchio, Angelo ;
Boehm, Michael ;
Dickstein, Kenneth ;
Falk, Volkmar ;
Filippatos, Gerasimos ;
Fonseca, Candida ;
Angel Gomez-Sanchez, Miguel ;
Jaarsma, Tiny ;
Kober, Lars ;
Lip, Gregory Y. H. ;
Maggioni, Aldo Pietro ;
Parkhomenko, Alexander ;
Pieske, Burkert M. ;
Popescu, Bogdan A. ;
Ronnevik, Per K. ;
Rutten, Frans H. ;
Schwitter, Juerg ;
Seferovic, Petar ;
Stepinska, Janina ;
Trindade, Pedro T. ;
Voors, Adriaan A. ;
Zannad, Faiez ;
Zeiher, Andreas ;
Bax, Jeroen J. ;
Baumgartner, Helmut ;
Ceconi, Claudio ;
Dean, Veronica ;
Deaton, Christi ;
Fagard, Robert ;
Funck-Brentano, Christian ;
Hasdai, David ;
Hoes, Arno ;
Kirchhof, Paulus ;
Knuuti, Juhani ;
Kolh, Philippe ;
McDonagh, Theresa ;
Moulin, Cyril ;
Popescu, Bogdan A. ;
Reiner, Zeljko ;
Sechtem, Udo ;
Sirnes, Per Anton ;
Tendera, Michal ;
Torbicki, Adam ;
Vahanian, Alec ;
Windecker, Stephan ;
McDonagh, Theresa ;
Sechtem, Udo .
EUROPEAN HEART JOURNAL, 2012, 33 (14) :1787-1847