Comparison of the dissolution of metaxalone tablets (Skelaxin) using USP apparatus 2 and 3

被引:3
|
作者
Cacace, J
Reilly, EE
Amann, A
机构
[1] Nova SE Univ, Coll Pharm, Ft Lauderdale, FL 33328 USA
[2] Pharma Qual Serv Inc, Maywood, NJ 07607 USA
[3] ACN Pharma LLC, Naperville, IL 60564 USA
来源
AAPS PHARMSCITECH | 2004年 / 5卷 / 01期
关键词
netaxalone; dissolution; pH dependence; apparatus; 3;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Comparison of the dissolution of metaxalone tablets (Skelaxin) usingUSP apparatus 2 and 3
    Janice Cacace
    Eugene E. Reilly
    Anton Amann
    AAPS PharmSciTech, 5 (1)
  • [2] Comparison of dissolution profiles for albendazole tablets using USP Apparatus 2 and 4
    de la Peña, MHY
    Alvarado, YV
    Domínguez-Ramírez, AM
    Arroyo, ARC
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2003, 29 (07) : 777 - 784
  • [3] COLLABORATIVE STUDY OF THE USP DISSOLUTION TEST FOR PREDNISONE TABLETS WITH APPARATUS-2
    COX, DC
    FURMAN, WB
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (05) : 670 - 676
  • [4] The impact of sinkers on coning issues exhibited by tablets in USP2 dissolution apparatus
    Terashima, Hanano
    Ozeki, Tetsuya
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 659
  • [5] Dissolution of Prednisone tablets on USP dissolution apparatus 4 (flow-through cell)
    Ashley, Alyssa J.
    Deng, Gang
    Tan, Shane X.
    Brown, William E.
    Manning, Ronald G.
    Wahab, Samir
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [6] Effect of a Fiber-Optic Probe on the Dissolution of Salicylic Acid Tablets in USP Apparatus 2
    Wang, Bing
    Bredael, Gerard
    Armenante, Piero M.
    DISSOLUTION TECHNOLOGIES, 2013, 20 (02): : 21 - 30
  • [7] Dissolution Performance of Verapamil-HCl Tablets Using USP Apparatus 2 and 4: Prediction of In Vivo Plasma Profiles
    Medina-Lopez, Jose R.
    Lugo-Ortiz, Regina
    Contreras-Jimenez, Juan M.
    Hurtado, Marcela
    Helmy, Sally A.
    DISSOLUTION TECHNOLOGIES, 2023, 30 (04): : 230 - 237
  • [8] Dissolution of prednisone tablets in the presence of an arch-shaped fiber optic probe in a USP dissolution testing apparatus 2
    Zhang, Yiran
    Bredael, Gerard
    Armenante, Piero M.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2013, 102 (08) : 2718 - 2729
  • [9] DISSOLUTION BEHAVIOR OF INDOMETHACIN CAPSULE FORMULATIONS - COMPARISON OF 2 TYPES OF USP APPARATUS
    SINGLA, AK
    MEDIRATTA, DK
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1988, 14 (05) : 721 - 731
  • [10] Development of a Dissolution Method for Gliclazide Modified-Release Tablets Using USP Apparatus 3 with in Vitro-in Vivo Correlation
    Bezerra, Kerolayne de Castro
    Pinto, Eduardo Costa
    Cabral, Lucio Mendes
    de Sousa, Valeria Pereira
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2018, 66 (07) : 701 - 707