His bundle pacing capture threshold stability during long-term follow-up and correlation with lead slack

被引:34
|
作者
Beer, Dominik [1 ]
Subzposh, Faiz A. [1 ]
Colburn, Shaun [1 ]
Naperkowski, Angela [1 ]
Vijayaraman, Pugazhendhi [1 ]
机构
[1] Cardiac Electrophysiol Geisinger Heart Inst MC 36, 1000 E Mt Blvd, Wilkes Barre, PA 18711 USA
来源
EUROPACE | 2021年 / 23卷 / 05期
关键词
His bundle pacing; Conduction system pacing; Lead slack; Pacemaker; Capture threshold; Lead revision; PERMANENT;
D O I
10.1093/europace/euaa350
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims His bundle pacing (HBP) is the most physiologic form of pacing. Long-term HBP capture threshold stability and its relation to lead characteristics at the time of implantation have not been adequately described. The aim of this study was to characterize HB capture threshold in follow-up and to identify potential lead characteristics predictive of lead capture instability. Methods and results Consecutive patients with successful HBP for bradycardia indications were identified from the Geisinger HBP registry. His bundle capture thresholds, baseline comorbidities, and radiographic lead slack characteristics were analysed. An increase in HB capture threshold >= 1V above implant values at any time during follow-up was tracked. Forty-four of the 294 studied (15%) experienced HB capture threshold increase by >= 1 V. Threshold increase was seen early (41% by 8 weeks, 66% by 1 year). Eighteen (6%) patients required lead revision in follow-up. Abnormal slack shape was associated with a trend toward capture threshold increase [hazard ratio (HR) 2.07; 95% confidence interval (CI) 0.9-4.6; P=0.08]. Non-perpendicular angle of lead insertion on radiography was associated with the capture threshold increase (HR 2.81, 95% CI 1.4-5.8; P <0.01). Conclusion His bundle capture threshold remains stable in the majority (85%) of patients. Implant characteristics may predict the threshold rise. Further evaluation of the aetiology of threshold increase and design changes in lead and delivery systems may lead to chronically stable capture thresholds. [GRAPHICS] .
引用
收藏
页码:757 / 766
页数:10
相关论文
共 50 条
  • [41] Atrioventricular Block Necessitating Chronic Ventricular Pacing After Tricuspid Valve Surgery in Patients With a Systemic Right Ventricle: Long-Term Follow-Up
    Nederend, Marieke
    Jongbloed, Monique R. M.
    Kies, Philippine
    Vliegen, Hubert W.
    Bouma, Berto J.
    Regeer, Madelien V.
    Koolbergen, Dave R.
    Hazekamp, Mark G.
    Schalij, Martin J.
    Egorova, Anastasia D.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [42] Long-Term Ventricular Pacing Dependency and Pacemaker Implantation Predictors after Transcatheter Aortic Valve Replacement - A 1-Year Follow-Up
    Pinto, Ricardo Alves
    Proenca, Tania
    Carvalho, Miguel Martins
    Pestana, Goncalo
    Lebreiro, Ana
    Adao, Luis
    Macedo, Filipe
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2022, 119 (04) : 522 - 530
  • [43] Long-Term Follow-Up of Arrhythmia Characteristics and Clinical Outcomes in Heart Transplant Patients
    Chang, H. -Y.
    Lo, L. -W.
    Feng, A. -N.
    Chiang, M. -C.
    Yin, W. -H.
    Young, M. -S.
    Chang, C. -Y.
    Chuang, Y. -C.
    Hartono, B.
    Chen, S. -A.
    Wei, J.
    TRANSPLANTATION PROCEEDINGS, 2013, 45 (01) : 369 - 375
  • [44] Long-term follow-up of abandoned transvenous defibrillator leads: a nationwide cohort study
    Elgaard, Anders Fyhn
    Johansen, Jens Brock
    Nielsen, Jens Cosedis
    Gerdes, Christian
    Riahi, Sam
    Philbert, Berit Thornvig
    Haarbo, Jens
    Melchior, Thomas Maria
    Larsen, Jacob Moesgaard
    EUROPACE, 2020, 22 (07): : 1097 - 1102
  • [45] Trends in replacement of pacemaker leads in the Netherlands: A long-term nationwide follow-up study
    de Vries, L. M.
    Leening, M. J. G.
    Dijk, W. A.
    Hooijschuur, A. M.
    Stricker, B. H.
    van Hemel, N. M.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (07): : 820 - 827
  • [46] Long-term follow-up of DDD and VDD pacing: a prospective non-randomized single-centre comparison of patients with symptomatic atrioventricular block
    Marchandise, Sebastien
    Scavee, Christophe
    de Waroux, Jean-Benoit le Polain
    de Meester, Christophe
    Vanoverschelde, Jean-Louis
    Debbas, Nadia
    EUROPACE, 2012, 14 (04): : 496 - 501
  • [47] Longevity of the Subcutaneous Implantable Defibrillator Long-Term Follow-Up of the European Regulatory Trial Cohort
    Theuns, Dominic A. M. J.
    Crozier, Ian G.
    Barr, Craig S.
    Hood, Margaret A.
    Cappato, Riccardo
    Knops, Reinoud E.
    Maass, Alexander H.
    Boersma, Lucas V. A.
    Jordaens, Luc
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (05) : 1159 - 1163
  • [48] Closed-loop cardiac pacing vs. conventional dual-chamber pacing with specialized sensing and pacing algorithms for syncope prevention in patients with refractory vasovagal syncope: results of a long-term follow-up
    Palmisano, Pietro
    Zaccaria, Maria
    Luzzi, Giovanni
    Nacci, Frida
    Anaclerio, Matteo
    Favale, Stefano
    EUROPACE, 2012, 14 (07): : 1038 - 1043
  • [49] Effect of Induced LV Dyssynchrony by Right Ventricular Apical Pacing on All-Cause Mortality and Heart Failure Hospitalization Rates at Long-Term Follow-Up
    Auger, Dominique
    Hoke, Ulas
    Marsan, Nina Ajmone
    Tops, Laurens F.
    Leong, Darryl P.
    Bertini, Matteo
    Schalij, Martin J.
    Bax, Jeroen J.
    Delgado, Victoria
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (06) : 631 - 637
  • [50] Comparison of right ventricular apex and right ventricular outflow tract septum pacing in the elderly with normal left ventricular ejection fraction: long-term follow-up
    Zhang, Hong-Xiang
    Qian, Jun
    Hou, Fa-Qin
    Liu, Yong-Ning
    Mao, Jian-Hua
    KARDIOLOGIA POLSKA, 2012, 70 (11) : 1130 - 1139