His bundle pacing capture threshold stability during long-term follow-up and correlation with lead slack

被引:34
|
作者
Beer, Dominik [1 ]
Subzposh, Faiz A. [1 ]
Colburn, Shaun [1 ]
Naperkowski, Angela [1 ]
Vijayaraman, Pugazhendhi [1 ]
机构
[1] Cardiac Electrophysiol Geisinger Heart Inst MC 36, 1000 E Mt Blvd, Wilkes Barre, PA 18711 USA
来源
EUROPACE | 2021年 / 23卷 / 05期
关键词
His bundle pacing; Conduction system pacing; Lead slack; Pacemaker; Capture threshold; Lead revision; PERMANENT;
D O I
10.1093/europace/euaa350
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims His bundle pacing (HBP) is the most physiologic form of pacing. Long-term HBP capture threshold stability and its relation to lead characteristics at the time of implantation have not been adequately described. The aim of this study was to characterize HB capture threshold in follow-up and to identify potential lead characteristics predictive of lead capture instability. Methods and results Consecutive patients with successful HBP for bradycardia indications were identified from the Geisinger HBP registry. His bundle capture thresholds, baseline comorbidities, and radiographic lead slack characteristics were analysed. An increase in HB capture threshold >= 1V above implant values at any time during follow-up was tracked. Forty-four of the 294 studied (15%) experienced HB capture threshold increase by >= 1 V. Threshold increase was seen early (41% by 8 weeks, 66% by 1 year). Eighteen (6%) patients required lead revision in follow-up. Abnormal slack shape was associated with a trend toward capture threshold increase [hazard ratio (HR) 2.07; 95% confidence interval (CI) 0.9-4.6; P=0.08]. Non-perpendicular angle of lead insertion on radiography was associated with the capture threshold increase (HR 2.81, 95% CI 1.4-5.8; P <0.01). Conclusion His bundle capture threshold remains stable in the majority (85%) of patients. Implant characteristics may predict the threshold rise. Further evaluation of the aetiology of threshold increase and design changes in lead and delivery systems may lead to chronically stable capture thresholds. [GRAPHICS] .
引用
收藏
页码:757 / 766
页数:10
相关论文
共 50 条
  • [31] LONG-TERM FOLLOW-UP OF VENTRICULAR ENDOCARDIAL PACING LEADS - COMPLICATIONS, ELECTRICAL PERFORMANCE, AND LONGEVITY OF 561 RIGHT VENTRICULAR LEADS
    KAZAMA, S
    NISHIYAMA, K
    MACHII, M
    TANAKA, K
    AMANO, T
    NOMURA, T
    OHUCHI, M
    KASAHARA, S
    NIE, M
    ISHIHARA, A
    JAPANESE HEART JOURNAL, 1993, 34 (02): : 193 - 200
  • [32] His bundle pacing is still relevant for patients with atrial fibrillation and bradycardia without prior atrioventricular nodal ablation: Data from mid-term follow-up
    Soral, Tomasz
    Gardas, Rafal
    Golba, Krzysztof S.
    Kulesza, Piotr
    Biernat, Jolanta
    Loboda, Danuta
    POLISH HEART JOURNAL-KARDIOLOGIA POLSKA, 2024, 82 (11): : 1119 - 1126
  • [33] Submammary Pacemakers and ICDs in Women: Long-Term Follow-up and Patient Satisfaction
    Giudici, Michael C.
    Carlson, Jacqueline I.
    Krupa, Roselyn K.
    Meierbachtol, Cynthia J.
    Vanwhy, Kent J.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (11): : 1373 - 1375
  • [34] Long-term follow-up in patients with intra-Hisian atrioventricular block
    Ishikawa T.
    Sumita S.
    Kikuchi M.
    Nakagawa T.
    Ogawa H.
    Hanada K.
    Kobayashi I.
    Kosuge M.
    Shigemasa T.
    Endo T.
    Kimura K.
    Usui T.
    Umemura S.
    Journal of Artificial Organs, 2000, 3 (2) : 149 - 153
  • [35] Long-Term Follow-Up of Second-Degree Heart Block in Children
    Epstein, Rebecca
    Liberman, Leonardo
    Silver, Eric S.
    PEDIATRIC CARDIOLOGY, 2023, 44 (07) : 1529 - 1535
  • [36] Long-Term Follow-Up of Second-Degree Heart Block in Children
    Rebecca Epstein
    Leonardo Liberman
    Eric S. Silver
    Pediatric Cardiology, 2023, 44 : 1529 - 1535
  • [37] Procedural safety and long-term follow-up after pacemaker implantation in nonagenarians
    Dang, Duc
    Galand, Vincent
    Loirat, Aurelie
    Auffret, Vincent
    Behar, Nathalie
    Mabo, Philippe
    Daubert, Jean-Claude
    Leclercq, Christophe
    Martins, Raphael P.
    CLINICAL CARDIOLOGY, 2018, 41 (10) : 1315 - 1321
  • [38] Procedural safety and long-term follow-up of pacemaker generator change in nonagenarians
    Hogan, George
    Dulai, Rajdip
    Veasey, Rick
    Patel, Nikhil
    HEART, 2023, 109 : A111 - A112
  • [39] Implantable cardioverter defibrillator remote monitoring is well accepted and easy to use during long-term follow-up
    Morichelli, Loredana
    Porfili, Antonio
    Quarta, Laura
    Sassi, Anna
    Ricci, Renato Pietro
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 41 (03) : 203 - 209
  • [40] Permanent His-bundle pacing maintains long-term ventricular synchrony and left ventricular performance, unlike conventional right ventricular apical pacing
    Catanzariti, Domenico
    Maines, Massimiliano
    Manica, Anna
    Angheben, Carlo
    Varbaro, Annamaria
    Vergara, Giuseppe
    EUROPACE, 2013, 15 (04): : 546 - 553