Stacking and discontinuous buffers in capillary zone electrophoresis

被引:0
作者
Shihabi, ZK [1 ]
机构
[1] Wake Forest Univ, Baptist Med Ctr, Dept Pathol, Winston Salem, NC 27109 USA
关键词
capillary electrophoresis; stacking; discontinuous buffers; catecholamines;
D O I
10.1002/1522-2683(20000801)21:14<2872::AID-ELPS2872>3.0.CO;2-G
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Discontinuous buffers for capillary zone electrophoresis (CZE) can be used under less rigid conditions compard to those for isotachophoresis for stacking. They can be prepared simply by modifying the sample itself, either by addition of small inorganic ions, low conductivity diluents, or both, and also by adjusting its pH, meanwhile injecting a large volume on the capillary. Zwitterionic and organic-based buffers such as triethanolamine and tris(hyroxmethyl)aminomethane (Tris) are well suited for stacking due to their low conductivity, provided the buffer is discontinuous as demonstrated here. A simple mechanism based on discontinuous buffers is described to explain many of the observed stacking types in CZE, pointing out the many similarities to transient isotachophoresis.
引用
收藏
页码:2872 / 2878
页数:7
相关论文
共 25 条
[1]   ANALYSIS OF DILUTE PEPTIDE SAMPLES BY CAPILLARY ZONE ELECTROPHORESIS [J].
AEBERSOLD, R ;
MORRISON, HD .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :79-88
[2]  
Bocek P., 1988, ANAL ISOTACHOPHORESI
[3]   Investigation of matrix effects in capillary zone electrophoresis [J].
Boden, J ;
Bachmann, K .
JOURNAL OF CHROMATOGRAPHY A, 1996, 734 (02) :319-330
[4]   Selective focusing of catecholamines and weakly acidic compounds by capillary electrophoresis using a dynamic pH junction [J].
Britz-McKibbin, P ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1242-1252
[5]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[6]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[7]   ELECTROOSMOTIC PROPERTIES AND PEAK BROADENING IN FIELD-AMPLIFIED CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
HELMER, JC .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1354-1361
[8]   Effect of pH and ions in the sample on stacking in capillary electrophoresis [J].
Friedberg, MA ;
Hinsdale, M ;
Shihabi, ZK .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :35-42
[9]   Recent application and developments of capillary isotachophoresis [J].
Gebauer, P ;
Bocek, P .
ELECTROPHORESIS, 1997, 18 (12-13) :2154-2161
[10]   SAMPLE SELF-STACKING IN ZONE ELECTROPHORESIS - THEORETICAL DESCRIPTION OF THE ZONE ELECTROPHORETIC SEPARATION OF MINOR COMPOUNDS IN THE PRESENCE OF BULK AMOUNTS OF A SAMPLE COMPONENT WITH HIGH MOBILITY AND LIKE CHARGE [J].
GEBAUER, P ;
THORMANN, W ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :47-57