Practical constraint definition in safety schemes for artificial pancreas systems

被引:2
|
作者
Rodriguez-Sarmiento, David L. [1 ,2 ]
Leon-Vargas, Fabian [2 ]
Garelli, Fabricio [3 ]
机构
[1] Univ Antonio Narino, Hlth Sci, Calle 58 A 37-94, Bogota 11911, Colombia
[2] Univ Antonio Narino, Mech Elect & Biomed Engn Fac, Bogota, Colombia
[3] Univ Nacl La Plata, Engn Fac, Buenos Aires, DF, Argentina
基金
奥地利科学基金会;
关键词
Insulin on board; artificial pancreas; type; 1; diabetes; in-silico assay; hypoglycemia; GLUCOSE CONTROL; INSULIN; LIMITATION; DELIVERY; FEEDBACK;
D O I
10.1177/03913988221095586
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Artificial pancreas systems usually define an insulin-on-board constraint ((IOB) over bar) for safety schemes to limit the insulin infusion and avoid hypoglycemia during the closed-loop performance. Several methods have been proposed with impractical considerations requiring information from the prandial events or complex procedures for regular ambulatory use. Methods: This paper presents a simple method that consists of two novel rules that allow finding an (IOB) over bar based only on common clinical parameters that do not require patient intervention during system operation. The method robustness was extensively evaluated using a control system coupled to a safety layer under several demanding scenarios implemented on the FDA-approved simulator for preclinical studies. Results: The method maintains a safe performance, even in the face of interpatient variability, hybrid and fully automatic implementations of an artificial pancreas system, and uncertain settings. Both proposed rules work as effectively or even better and without the patient intervention than other methods that have already been clinically validated. Conclusion: This method can be used to define a constant (IOB) over bar that ensures performance and safety of the control system, even under scenarios with incorrect clinical data. Unlike other methods, this method only requires reliable information that is easily obtained from the patient, such as their total daily dose of insulin or body mass.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [1] Integration of a Safety Module to Prevent Rebound Hypoglycemia in Closed-Loop Artificial Pancreas Systems
    Villa-Tamayo, Maria F.
    Colmegna, Patricio
    Breton, Marc D.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, : 318 - 323
  • [2] Safety Layer Design for Improved Glucose Regulation in Artificial Pancreas Systems
    Da Rosa Jurao, Fernando Leonel
    Montero, Melina
    Fushimi, Emilia
    Rosales, Nicolas
    Garelli, Fabricio
    ADVANCES IN BIOENGINEERING AND CLINICAL ENGINEERING, VOL 2, SABI 2023, 2024, 114 : 272 - 285
  • [3] Internal model control based module for the elimination of meal and exercise announcements in hybrid artificial pancreas systems
    Sala-Mira, Ivan
    Garcia, Pedro
    Diez, Jose-Luis
    Bondia, Jorge
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 226
  • [4] Event-Triggered Model Predictive Control for Embedded Artificial Pancreas Systems
    Chakrabarty, Ankush
    Zavitsanou, Stamatina
    Doyle, Francis J., III
    Dassau, Eyal
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (03) : 575 - 586
  • [5] Glucagon in artificial pancreas systems: Potential benefits and safety profile of future chronic use
    Taleb, Nadine
    Haidar, Ahmad
    Messier, Virginie
    Gingras, Veronique
    Legault, Laurent
    Rabasa-Lhoret, Remi
    DIABETES OBESITY & METABOLISM, 2017, 19 (01) : 13 - 23
  • [6] Safety Auxiliary Feedback Element for the Artificial Pancreas in Type 1 Diabetes
    Revert, A.
    Garelli, F.
    Pico, J.
    De Battista, H.
    Rossetti, P.
    Vehi, J.
    Bondia, J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (08) : 2113 - 2122
  • [7] A Hybrid Automata Approach for Monitoring the Patient in the Loop in Artificial Pancreas Systems
    Beneyto, Aleix
    Puig, Vicenc
    Bequette, B. Wayne
    Vehi, Josep
    SENSORS, 2021, 21 (21)
  • [8] Interval Safety Layer Coupled With an Impulsive MPC for Artificial Pancreas to Handle Intrapatient Variability
    Villa-Tamayo, Maria F.
    Garcia-Jaramillo, Maira
    Leon-Vargas, Fabian
    Rivadeneira, Pablo S.
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [9] A review on the use of adjunctive therapies in artificial pancreas systems
    Furio-Novejarque, Clara
    Diez, Jose-Luis
    Bondia, Jorge
    IFAC PAPERSONLINE, 2024, 58 (24): : 297 - 302
  • [10] Pathway to Artificial Pancreas Systems Revisited: Moving Downstream
    Kowalski, Aaron
    DIABETES CARE, 2015, 38 (06) : 1036 - 1043