Biodynamic response of human fingers in a power grip subjected to a random vibration

被引:37
作者
Dong, RG [1 ]
Welcome, DE [1 ]
McDowell, TW [1 ]
Wu, JZ [1 ]
机构
[1] NIOSH, E&CTB, HELD, CDC, Morgantown, WV 26505 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2004年 / 126卷 / 04期
关键词
D O I
10.1115/1.1784479
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background. Knowledge of the biodynamic response (BR) of the human hand-arm system is an important part of the foundation for the measurement and assessment of hand-transmitted vibration exposure. This study investigated the BR of human fingers in a power grip subjected to a random vibration. Method. Ten male subjects were used in the experiment. Each subject applied three coupling actions to a simulated tool handle at three different finger grip force levels. Results and Conclusions. The BR is practically independent of the hand coupling actions for frequencies at or above 100 Hz. Above 50 Hz, the BR is correlated to finger and hand sizes. Increasing the finger coupling force significantly increases the BR. Therefore, hand forces should be measured and used when assessing hand-transmitted vibration exposure. The results also show that under a constant-velocity vibration, the finger vibration power absorption at frequencies above 200 Hz: is approximately twice that at frequencies below 100 Hz. This suggests that the frequency weighting specified in the current ISO 5349-I (2001) may underestimate the high frequency effect on vibration-induced finger disorders.
引用
收藏
页码:447 / 457
页数:11
相关论文
共 36 条
[1]  
[Anonymous], 1999, 13753 ISO
[2]   Haemodynamic changes in ipsilateral and contralateral fingers caused by acute exposures to hand transmitted vibration [J].
Bovenzi, M ;
Griffin, MJ .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1997, 54 (08) :566-576
[3]   Exposure-response relationship in the hand-arm vibration syndrome: an overview of current epidemiology research [J].
Bovenzi, M .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1998, 71 (08) :509-519
[4]  
BURSTROM L, 1990, THESIS LULEA U TECHN
[5]   ENERGY DISSIPATION IN HUMAN HAND-ARM EXPOSED TO RANDOM VIBRATION [J].
CUNDIFF, JS .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 59 (01) :212-214
[6]   VIBRATION FROM RIVETING TOOLS IN THE FREQUENCY-RANGE 6 HZ-10 MHZ AND RAYNAUDS-PHENOMENON [J].
DANDANELL, R ;
ENGSTROM, K .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1986, 12 (04) :338-342
[7]   A PNEUMATIC TOOL VIBRATION ISOLATOR [J].
DOBRY, MW ;
BARCZEWSKI, R ;
STAMMERS, CW .
JOURNAL OF SOUND AND VIBRATION, 1992, 153 (01) :171-175
[8]   An evaluation of the standardized chipping hammer test specified in ISO 8662-2 [J].
Dong, RG ;
McDowell, TW ;
Welcome, DE ;
Warren, C ;
Schopper, AW .
ANNALS OF OCCUPATIONAL HYGIENE, 2004, 48 (01) :39-49
[9]  
Dong RG, 2003, J TEST EVAL, V31, P234
[10]   Hand-transmitted vibration and biodynamic response of the human hand-arm: A critical review [J].
Dong, RG ;
Rakheja, S ;
Schopper, AW ;
Han, B ;
Smutz, WR .
CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 2001, 29 (04) :393-439