Total on-line analysis of a target protein from plasma by immunoextraction, digestion and liquid chromatography-mass spectrometry

被引:21
作者
Cingoez, A. [1 ]
Hugon-Chapuis, F. [1 ]
Pichon, V. [1 ]
机构
[1] ESPCI ParisTech, Dept Environm & Analyt Chem, UMR PECSA 7195, F-75231 Paris 05, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 02期
关键词
Immunoextraction; Immobilized pepsin; On-On-line analysis; Protein analysis; LC-MS/MS; SOLUTION-PHASE DIGESTION; IMMUNOAFFINITY CHROMATOGRAPHY; SAMPLE PREPARATION; TRYPSIN IMMOBILIZATION; TRACE ANALYSIS; SYSTEM; PEPSIN; IDENTIFICATION; SEPARATION; PROTEOMICS;
D O I
10.1016/j.jchromb.2009.07.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A total on-line analysis of a target protein from a plasma sample was made using a selective immunoextraction step coupled on-line to an immobilized enzymatic reactor (IMER) for the protein digestion followed by LC-MS/MS analysis For the development of this device. cytochrome c was chosen as model protein clue to its well-known sequence An immunosorbent (IS) based on the covalent immobilization of anti-cytochrome c antibodies on a solid support was made and an immunoextraction procedure was carefully developed to assess a selective extraction of the target protein from plasma. For the first time. IS was easily coupled on-line with a I laboratory-made IMER based on pepsin The whole on-line device (ISIMER-LC-MS/MS) allowed the quantification of cytochrome c from 8 5 pmol to 1 7 nmol in buffer medium Finally. this device was applied to the analysis of only 85 pmol of cytochrome c from plasma with a RSD value lower than 10%(n=3) (C) 2009 Elsevier B.V. All rights reserved
引用
收藏
页码:213 / 221
页数:9
相关论文
共 44 条
[1]   Candidate-based proteomics in the search for biomarkers of cardiovascular disease [J].
Anderson, L .
JOURNAL OF PHYSIOLOGY-LONDON, 2005, 563 (01) :23-60
[2]  
Bakhtiar Ray, 2008, Journal of Pharmacological and Toxicological Methods, V57, P85, DOI 10.1016/j.vascn.2007.10.002
[3]   Trace analysis of proteins using postseparation solution-phase digestion and electrospray mass spectrometric detection of marker peptides [J].
Bruyneel, B. ;
Hoos, J. S. ;
Smoluch, M. T. ;
Lingeman, H. ;
Niessen, W. M. A. ;
Irth, H. .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1591-1598
[4]   Improving digestion efficiency under H/D exchange conditions with activated pepsinogen coupled columns [J].
Busby, Scott A. ;
Chalmers, Michael J. ;
Griffin, Patrick R. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 259 (1-3) :130-139
[5]   Development of a bioreactor based on trypsin immobilized on monolithic support for the on-line digestion and identification of proteins [J].
Calleri, E ;
Temporini, C ;
Perani, E ;
Stella, C ;
Rudaz, S ;
Lubda, D ;
Mellerio, G ;
Veuthey, JL ;
Caccialanza, G ;
Massolini, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) :99-109
[6]   Hyphenation of multi-dimensional chromatography and mass spectrometry for the at-line-analysis of the integrity of recombinant protein drugs [J].
Canarelli, S ;
Fisch, I ;
Freitag, R .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 775 (01) :27-35
[7]   ENZYME-BASED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY SUPPORTS AS PROBES OF ENZYME-ACTIVITY AND INHIBITION - THE IMMOBILIZATION OF TRYPSIN AND ALPHA-CHYMOTRYPSIN ON AN IMMOBILIZED ARTIFICIAL MEMBRANE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY SUPPORT [J].
CHUI, WK ;
WAINER, IW .
ANALYTICAL BIOCHEMISTRY, 1992, 201 (02) :237-245
[8]   Evaluation of various immobilized enzymatic microreactors coupled on-line with liquid chromatography and mass spectrometry detection for quantitative analysis of cytochrome c [J].
Cingoz, A. ;
Hugon-Chapuis, F. ;
Pichon, V. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1209 (1-2) :95-103
[9]   Experimental comparison of three monoclonal antibodies for the class-selective immunoextraction of triazines - Correlation with molecular modeling and principal component analysis studies [J].
Delaunay-Bertoncini, N ;
Pichon, V ;
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 2003, 999 (1-2) :3-15
[10]   An integrated high-performance liquid chromatography-mass spectrometry system for the activity-dependent analysis of matrix metalloproteases [J].
Freije, Robert ;
Klein, Theo ;
Ooms, Bert ;
Kauffman, Henk F. ;
Bischoff, Rainer .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :417-425