Dynamic Modelling and Performance Prediction of a Multi-unit Baseline Air Conditioning System for a Generic Bus under Part-Load Conditions

被引:3
作者
Afrasiabian, Ehsan [1 ]
Douglas, Roy [1 ]
Best, Robert [2 ]
机构
[1] Queens Univ Belfast, Belfast, Antrim, North Ireland
[2] Wrightbus, Ballymena, North Ireland
基金
“创新英国”项目;
关键词
Air conditioning in buses; Refrigeration cycle; Thermal comfort; MATLAB; Simulink; TRANSIENT THERMAL-MODEL; CABIN;
D O I
10.4271/02-14-02-0015
中图分类号
U [交通运输];
学科分类号
08 ; 0823 ;
摘要
A dynamic model of a multi-unit air conditioning (AC) system in a generic bus was developed to investigate different control strategies on the system performance and the cabin comfort level. In this study, a part-load condition was considered, where adopting a proper strategy for governing a multi-unit system is important. Simulink and Simscape toolbox from MATLAB (R2019a) were used to build up the real-time model by integrating a cooling system with a cabin sub-model. The cooling system consists of two independently controlled units, based on a Vapor Compression Cycle (VCC). The cabin is modelled using a moisture air network and is coupled with the cooling system to exchange heat with the refrigerant through the evaporators. Moreover, the sensible and latent loads are incorporated into the cabin by a thermal network. Six different strategies were implemented using different criteria to investigate the average power and Coefficient of Performance (COP) under a part-load condition. The comfort level was obtained in terms of the Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) indices. Results are suggestive of a link between the implemented control strategy of a multi-unit AC system and its performance. Results showed that five out of the six proposed strategies might be chosen, depending on the adopted trade-off policy between the comfort level and the system energy demand. In this way, the numerical approach introduced here, along with the combination of the presented findings, provides good support for the decision-making on thermal management inside the cabin, based on the energy consumption and the thermal comfort level.
引用
收藏
页码:193 / 204
页数:12
相关论文
共 28 条
[1]   Investigation on the Performance of a Compact Three-Fluid Combined Membrane Contactor for Dehumidification in Electric Vehicles [J].
Afrasiabian, Ehsan ;
Iliev, Oleg ;
Shklyar, Inga ;
Lazzari, Stefano ;
Boero, Federica .
ENERGIES, 2019, 12 (09)
[2]  
[Anonymous], 2005, ISO77302005
[3]  
[Anonymous], 2018, MATLAB VERS 9 3 R201
[4]  
[Anonymous], 2017, 55 ANSIASHRAE
[5]  
Fanger P.O., 1982, Thermal comfort
[6]  
Fayazbakhsh M., 2013, 2013011507 SAE, DOI DOI 10.4271/2013-01-1507
[7]   Predictive air-conditioner control for electric buses with passenger amount variation forecast [J].
He, Hongwen ;
Yan, Mei ;
Sun, Chao ;
Peng, Jiankun ;
Li, Menglin ;
Jia, Hui .
APPLIED ENERGY, 2018, 227 :249-261
[8]   Indoor air quality assessment in the air traffic control tower of the Athens Airport, Greece [J].
Helmis, Costas G. ;
Assimakopoulos, Vasiliki D. ;
Flocas, Helena A. ;
Stathopoulou, Ourania I. ;
Sgouros, George ;
Hatzaki, Maria .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2009, 148 (1-4) :47-60
[9]  
Howell R.H., 2013, Principles of Heating, Ventilating and Air Conditioning, V7th
[10]   Modelling and optimal energy-saving control of automotive air-conditioning and refrigeration systems [J].
Huang, Yanjun ;
Khajepour, Amir ;
Bagheri, Farshid ;
Bahrami, Majid .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2017, 231 (03) :291-309