Optimisation of cold-formed steel beams for best seismic performance in bolted moment connections

被引:29
作者
Mojtabaei, Seyed Mohammad [1 ]
Hajirasouliha, Iman [1 ]
Ye, Jun [2 ]
机构
[1] Univ Sheffield, Dept Civil Engn & Struct Engn, Sheffield S1 3JD, S Yorkshire, England
[2] Imperial Coll London, Dept Civil & Environm Engn, London SW7 2AZ, England
基金
英国工程与自然科学研究理事会;
关键词
Cold-formed steel (CFS); Bolted moment connection; Particle swarm optimisation (PSO); Finite element (FE) analysis; Energy dissipation; Ductility; SECTIONS; STRENGTH; BEHAVIOR;
D O I
10.1016/j.jcsr.2021.106621
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Typical thin-walled cold-formed steel (CFS) elements and connections used in portal frames are not generally suitable for moment-resisting frames in high seismic regions due to their low ductility and energy dissipation capacity and inherited susceptibility to local/global instabilities. This study aims to improve the seismic perfor-mance of CFS moment-resisting frames by developing a methodology to obtain more efficient bolted moment connections using optimised CFS beams with enhanced non-linear post-buckling behaviour. By taking into ac-count material non-linearity and geometrical imperfection effects, the detailed Finite Element (FE) models of a typical CFS bolted moment connection is developed using ABAQUS software, and then validated based on exper-imental cyclic test results. Particle Swarm Optimisation (PSO) algorithm is linked to GMNIA ABAQUS FE analysis to optimise CFS bolted moment connections based on either energy dissipation capacity or ductility. To demon-strate the efficiency of the method, connections with five different beam cross-sectional shapes are optimised, and the results are compared with a standard CFS channel section used as a benchmark. The relative dimensions of the cross-sections, the inclination of the lip stiffeners, and the location of triangular intermediate stiffeners are selected as main design variables. To provide practical beam cross-sections, the plate slenderness limit values de -fined by Eurocode 3 (EC3) along with a range of manufacturing limitations are imposed as design constraints in the optimisation process. It is shown that, for a given plate width and thickness, the proposed optimisation framework results in a considerable (up to 195%) improvement in the energy dissipation capacity and ductility of the CFS bolted moment connections. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 57 条
[1]  
AISI (American Iron and Steel Institute), 2015, AISI S400-15
[2]  
[Anonymous], 2014, ABAQUS CAE USERS MAN
[3]  
[Anonymous], 2005, EUR 3 DES STEEL STRU
[4]  
[Anonymous], MATL R2015B
[5]  
[Anonymous], 2013, AISI S100-12
[6]  
[Anonymous], 2016, 34116 ANSIAISC
[7]  
[Anonymous], 2011, THESIS U SHEFFIELD
[8]  
AS/NZS, 2018, AS/NZS 4600: 2018
[9]  
ASCE/SEI 41-17, 2017, 4117 ASCESEI
[10]   Experimental investigation of long-span cold-formed steel double channel portal frames [J].
Blum, H. B. ;
Rasmussen, K. J. R. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 155 :316-330