Dose and perceived image quality in chest radiography

被引:70
作者
Veldkamp, Wouter J. H. [1 ]
Kroft, Lucia J. M. [1 ]
Geleijns, Jacob [1 ]
机构
[1] Leiden Univ, Dept Radiol, Med Ctr, NL-2333 ZA Leiden, Netherlands
关键词
Chest radiography; Dose; Image quality; COUPLED-DEVICE RADIOGRAPHY; SCREEN-FILM RADIOGRAPHY; FLAT-PANEL-DETECTOR; DIGITAL RADIOGRAPHY; AMORPHOUS-SILICON; SIMULATED NODULES; REDUCTION; CT; DETECTABILITY; OPTIMIZATION;
D O I
10.1016/j.ejrad.2009.05.039
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chest radiography is the most commonly performed diagnostic X-ray examination. The radiation dose to the patient for this examination is relatively low but because of its frequent use. the contribution to the collective dose is considerable. Consequently, optimization of dose and image quality offers a challenging area of research. In this article studies on dose reduction, different detector technologies, optimization of image acquisition and new technical developments in image acquisition and post processing will be reviewed. Studies indicate that dose reduction in PA chest images to at least 50% of commonly applied dose levels does not affect diagnosis in the lung fields; however, dose reduction in the mediastinum, upper abdomen and retrocardiac areas appears to directly deteriorate diagnosis. In addition to patient dose, also the design of the various digital detectors seems to have an effect on image quality. With respect to image acquisition, studies showed that using a lower tube voltage improves visibility of anatomical structures and lesions in digital chest radiographs but also increases the disturbing appearance of ribs. New techniques that are currently being evaluated are dual energy, tomosynthesis, temporal subtraction and rib suppression. These technologies may improve diagnostic chest X-ray further. They may for example reduce the negative influence of over projection of ribs, referred to as anatomic noise. In chest X-ray this type of noise may be the dominating factor in the detection of nodules. In conclusion, optimization and new developments will enlarge the value of chest X-ray as a mainstay in the diagnosis of chest diseases. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 42 条
[1]   Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography [J].
Aufrichtig, R .
MEDICAL PHYSICS, 1999, 26 (07) :1349-1358
[2]   MISSED BRONCHOGENIC-CARCINOMA - RADIOGRAPHIC FINDINGS IN 27 PATIENTS WITH A POTENTIALLY RESECTABLE LESION EVIDENT IN RETROSPECT [J].
AUSTIN, JHM ;
ROMNEY, BM ;
GOLDSMITH, LS .
RADIOLOGY, 1992, 182 (01) :115-122
[3]   Method of simulating dose reduction for digital radiographic systems [J].
Båth, M ;
Håkansson, M ;
Tingberg, A ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :253-259
[4]   Nodule detection in digital chest radiography:: Effect of anatomical noise [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Hoeschen, C ;
Tischenko, O ;
Kheddache, S ;
Vikgren, J ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :109-113
[5]   On site evaluation of three flat panel detectors for digital radiography [J].
Borasi, G ;
Nitrosi, A ;
Ferrari, P ;
Tassoni, D .
MEDICAL PHYSICS, 2003, 30 (07) :1719-1731
[6]  
BUSHBERG JT, 2001, IMAGE QUALITY ESSENT, P255
[7]   DIGITAL CHEST RADIOGRAPHY WITH PHOTOSTIMULABLE STORAGE PHOSPHORS - SIGNAL-TO-NOISE RATIO AS A FUNCTION OF KILOVOLTAGE WITH MATCHED EXPOSURE RISK [J].
CHOTAS, HG ;
FLOYD, CE ;
DOBBINS, JT ;
RAVIN, CE .
RADIOLOGY, 1993, 186 (02) :395-398
[8]   Advances in computed radiography systems and their physical imaging characteristics [J].
Cowen, A. R. ;
Davies, A. G. ;
Kengyelics, S. M. .
CLINICAL RADIOLOGY, 2007, 62 (12) :1132-1141
[9]  
Daffner RH, 1999, CLIN RADIOLOGY ESSEN
[10]   Digital chest radiography: Effect of temporal subtraction images on detection accuracy [J].
Difazio, MC ;
MacMahon, H ;
Xu, XW ;
Tsai, P ;
Shiraishi, J ;
Armato, SG ;
Doi, K .
RADIOLOGY, 1997, 202 (02) :447-452