Intrinsic Passive Stiffness of 2 Constructs of Varus Proximal Femoral Osteotomy: External Fixator or Blade Plate

被引:2
作者
Paliobeis, Christos P. [1 ]
Kanellopoulos, Anastasios D. [1 ]
Babis, George C. [1 ]
Magnissalis, Evangelos A. [2 ]
Catling, Jonathan C. [3 ]
Papagelopoulos, Panayiotis J. [1 ]
Soucacos, Panayotis N. [1 ]
机构
[1] Univ Athens, Sch Med, Dept Orthopaed Surg 1, Birmingham B30 1SU, W Midlands, England
[2] Univ Athens, KAT Hosp Kifissia, Lab Res Musculoskeletal Syst, Athens, Greece
[3] Univ Worcester, Worcester, MA USA
关键词
external fixator; proximal femoral osteotomy; varus intertrochanteric osteotomy; biomechanics; hip dysplasia; PEDIATRIC NEUROMUSCULAR POPULATION; HIP SCREW; PERTROCHANTERIC FRACTURES; GREATER TROCHANTER; EPIPHYSEODESIS; EPIPHYSIS; NECROSIS; GROWTH; FEMUR;
D O I
10.1097/BPO.0b013e3181d8fa53
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Despite the published clinical evidence of the implementation of external fixation of proximal femoral osteotomies, there is lack of specific laboratory justification. Methods: Two groups of 5 adult composite femur constructs of varus proximal femoral osteotomy were tested under incremental and cyclical loading of up to 600N along the mechanical axis. Five were fixed with a blade plate and another 5 with a monolateral external fixator. Load versus displacement curves were produced, and passive stiffness of all constructs was calculated. The described loading regime aimed to simulate the initial postoperative state and provide data for the assessment of vertical intrinsic passive stiffness in partial weight-bearing conditions. Results: Although the blade plate constructs showed higher average stiffness, this was not statistically significant [F(1,8) = 1.712, P = 0.23]. No construct failed. No failure or plastic deformation was observed under the described loading regime. Conclusions: Vertical intrinsic passive stiffness in partial weight-bearing conditions during the initial postoperative period can be considered satisfactory subsequent to unilateral external fixation of a varus intertrochanteric osteotomy.
引用
收藏
页码:351 / 356
页数:6
相关论文
共 28 条
  • [1] BEAUCHESNE R, 1992, J PEDIATR ORTHOPED, V12, P735
  • [2] Bombelli R., 1993, Structure and function in normal and abnormal hips : how to rescue mechanically jeopardized hips
  • [3] CHAO EYS, 1989, CLIN ORTHOP RELAT R, P24
  • [6] Absorbable screws through the greater trochanter do not disturb physeal growth - Rabbit experiments
    Gil-Albarova, J
    Fini, M
    Gil-Albarova, R
    Melgosa, M
    Aldini-Nicolo, N
    Giardino, R
    Seral, F
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (03): : 273 - 276
  • [7] THE EFFECT OF EXTERNAL FIXATION STIFFNESS ON EARLY HEALING OF TRANSVERSE OSTEOTOMIES
    GILBERT, JA
    DAHNERS, LE
    ATKINSON, MA
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (03) : 389 - 397
  • [8] Graham HK, 2005, J PEDIATR ORTHOP B, V14, P307
  • [9] The role of AO external fixation in proximal femoral osteotomies in the pediatric neuromuscular population
    Handelsman, JE
    Weinberg, J
    Razi, A
    Mulley, DA
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2004, 13 (05): : 303 - 307
  • [10] Which implant for proximal femoral osteotomy in children?: A comparison of the AO (ASIF) 90° fixed-angle blade plate and the Richards intermediate hip screw
    Hau, R
    Dickens, DRV
    Nattrass, GR
    O'Sullivan, M
    Torode, IP
    Graham, HK
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2000, 20 (03) : 336 - 343