Diagnostic accuracy of ultrasonography for detecting nasogastric tube (NGT) placement in adults: A systematic review and meta analysis

被引:21
|
作者
Tian, Lin [1 ]
Wendy, Gifford [2 ]
Lan Yutao [1 ]
Qin Xiuqun [3 ]
Liu Xuelian [3 ]
Wang Juan [1 ]
Yang Biping [1 ]
You Tianhui [1 ]
Chen Ken [1 ]
机构
[1] Guangdong Pharmaceut Univ, Sch Nursing, 283 Jianghai Ave, Guangzhou, Guangdong, Peoples R China
[2] Univ Ottawa, Fac Hlth Sci, Sch Nursing, Ottawa, ON, Canada
[3] Sun Yat Sen Univ, Affiliated Hosp 3, Nursing Dept, 600 Tianhe Rd, Guangzhou, Guangdong, Peoples R China
关键词
Nasogastric tube; Ultrasonography; Adult; Systematic review; GASTRIC TUBE; POSITION; CONFIRM; ULTRASOUND;
D O I
10.1016/j.ijnurstu.2017.03.005
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To review the evidence on diagnostic accuracy of ultrasonography for detecting correct nasogastric tube (NGT) placement in adults compared to X-ray as the reference standard. Methods: This is a systematic review and meta-analysis of observational studies, searched in the literature between 1961 and 2015. We included studies which compared the diagnostic accuracy of ultrasonography detection for NGT placement with X-ray in adult patients who were undergoing NGT placement for any reason in any care setting. We searched published studies in the following electronic databases: Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, Web of Science, WanFang Data, China Journal Net, and the Chinese Biomedical Literature Database. Both English and non-English-language articles were retrieved. Risk of bias was assessed using a standard procedure according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. Results: We included five studies involving a total of 420 adult patients undergoing nasogastric tube placement: three trials were undertaken in mechanically ventilated patients in prehospital settings and two involved participants with comma or severe trauma in emergency room or intensive care unit (ICU). Pooled results showed that ultrasonography had a sensitivity of 0.93 (95% CI 0.87 to 0.97), and specificity of 0.97 (95% CI 0. 23 to 1.00), suggesting that diagnostic performance of ultrasound is useful to confirm correct NGT placement, but not optimal to detect incorrect NGT position. This was confirmed through a summary receiver operator characteristics (SROC) curve that showed the area under the curve was 0.96 (95% CI 0.94 to 0.98). Discussion: The main limitation of the review is the relatively moderate level of heterogeneity of included studies which may partially undermine the reliability and reproducibility of results. The insufficient studies included did not allow identification of possible sources of heterogeneity and exploration of reporting bias. Due to heterogeneity of studies, the diagnostic performance of ultrasonography could only be drawn cautiously. Physicians and nurses should perform routine X-ray if visualization of NGT is not possible. More well designed studies exploring ultrasound as a diagnostic tool for accuracy of NGT placement are needed to strengthen the current evidence. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:80 / 88
页数:9
相关论文
共 50 条
  • [31] Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis
    Zhao, Lina
    Han, Yubo
    Che, Yanling
    Zhang, Xuesong
    Luo, Min
    Li, Jinzhu
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2023, 13 (05) : 893 - 905
  • [32] Diagnostic accuracy of endometrial sampling tests for detecting endometrial cancer: a systematic review and meta-analysis
    Sakna, Noha Abdelsattar
    Elgendi, Marwa
    Salama, Mohamed Hamed
    Zeinhom, Ahmed
    Labib, Somia
    Nabhan, Ashraf Fawzy
    BMJ OPEN, 2023, 13 (06):
  • [33] Transtracheal ultrasound for verification of endotracheal tube placement: a systematic review and meta-analysis
    Das, Saurabh Kumar
    Choupoo, Nang Sujali
    Haldar, Rudrashish
    Lahkar, Amitabh
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (04): : 413 - 423
  • [34] Diagnostic accuracy of eFAST in the trauma patient: a systematic review and meta-analysis
    Netherton, Stuart
    Milenkovic, Velimir
    Taylor, Mark
    Davis, Philip J.
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2019, 21 (06) : 727 - 738
  • [35] Diagnostic accuracy of preoperative ultrasonography in predicting contralateral inguinal hernia in children: a systematic review and meta-analysis
    K. M. A. Dreuning
    C. E. M. ten Broeke
    J. W. R. Twisk
    S. G. F. Robben
    R. R. van Rijn
    J. I. M. L. Verbeke
    L. W. E. van Heurn
    J. P. M. Derikx
    European Radiology, 2019, 29 : 866 - 876
  • [36] Diagnostic accuracy of palpation and ultrasonography for diagnosing infantile hypertrophic pyloric stenosis: a systematic review and meta- analysis
    Van Den Bunder, Fenne Aim
    Derikx, Joep Pm
    Kiblawi, Rick
    Van Rijn, Rick R.
    Dingemann, Jens
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1139)
  • [37] Complications Associated With Nasogastric Tube Placement in the Acute Phase of Stroke: A Systematic Review
    Nascimento, Ana
    Carvalho, Mariana
    Nogueira, Jerina
    Abreu, Pedro
    Nzwalo, Hipolito
    JOURNAL OF NEUROSCIENCE NURSING, 2018, 50 (04) : 193 - 198
  • [38] Performance comparison of ultrasonography and magnetic resonance imaging in their diagnostic accuracy of placenta accreta spectrum disorders: a systematic review and meta-analysis
    Hong, Shibin
    Le, Yiping
    Lio, Ka U.
    Zhang, Ting
    Zhang, Yu
    Zhang, Ning
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [39] Diagnostic accuracy of transabdominal ultrasound in detecting prenatal cleft lip and palate: a systematic review
    Maarse, W.
    Berge, S. J.
    Pistorius, L.
    van Barneveld, T.
    Kon, M.
    Breugem, C.
    van der Molen, A. B. Mink
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 35 (04) : 495 - 502
  • [40] Diagnostic Accuracy of Hepatic Vein Arrival Time Performed with Contrast-Enhanced Ultrasonography for Cirrhosis: A Systematic Review and Meta-Analysis
    Kim, Gaeun
    Shim, Kwang Yong
    Baik, Soon Koo
    GUT AND LIVER, 2017, 11 (01) : 93 - 101