Diagnostic accuracy of ultrasonography for detecting nasogastric tube (NGT) placement in adults: A systematic review and meta analysis

被引:21
|
作者
Tian, Lin [1 ]
Wendy, Gifford [2 ]
Lan Yutao [1 ]
Qin Xiuqun [3 ]
Liu Xuelian [3 ]
Wang Juan [1 ]
Yang Biping [1 ]
You Tianhui [1 ]
Chen Ken [1 ]
机构
[1] Guangdong Pharmaceut Univ, Sch Nursing, 283 Jianghai Ave, Guangzhou, Guangdong, Peoples R China
[2] Univ Ottawa, Fac Hlth Sci, Sch Nursing, Ottawa, ON, Canada
[3] Sun Yat Sen Univ, Affiliated Hosp 3, Nursing Dept, 600 Tianhe Rd, Guangzhou, Guangdong, Peoples R China
关键词
Nasogastric tube; Ultrasonography; Adult; Systematic review; GASTRIC TUBE; POSITION; CONFIRM; ULTRASOUND;
D O I
10.1016/j.ijnurstu.2017.03.005
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To review the evidence on diagnostic accuracy of ultrasonography for detecting correct nasogastric tube (NGT) placement in adults compared to X-ray as the reference standard. Methods: This is a systematic review and meta-analysis of observational studies, searched in the literature between 1961 and 2015. We included studies which compared the diagnostic accuracy of ultrasonography detection for NGT placement with X-ray in adult patients who were undergoing NGT placement for any reason in any care setting. We searched published studies in the following electronic databases: Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, Web of Science, WanFang Data, China Journal Net, and the Chinese Biomedical Literature Database. Both English and non-English-language articles were retrieved. Risk of bias was assessed using a standard procedure according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. Results: We included five studies involving a total of 420 adult patients undergoing nasogastric tube placement: three trials were undertaken in mechanically ventilated patients in prehospital settings and two involved participants with comma or severe trauma in emergency room or intensive care unit (ICU). Pooled results showed that ultrasonography had a sensitivity of 0.93 (95% CI 0.87 to 0.97), and specificity of 0.97 (95% CI 0. 23 to 1.00), suggesting that diagnostic performance of ultrasound is useful to confirm correct NGT placement, but not optimal to detect incorrect NGT position. This was confirmed through a summary receiver operator characteristics (SROC) curve that showed the area under the curve was 0.96 (95% CI 0.94 to 0.98). Discussion: The main limitation of the review is the relatively moderate level of heterogeneity of included studies which may partially undermine the reliability and reproducibility of results. The insufficient studies included did not allow identification of possible sources of heterogeneity and exploration of reporting bias. Due to heterogeneity of studies, the diagnostic performance of ultrasonography could only be drawn cautiously. Physicians and nurses should perform routine X-ray if visualization of NGT is not possible. More well designed studies exploring ultrasound as a diagnostic tool for accuracy of NGT placement are needed to strengthen the current evidence. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:80 / 88
页数:9
相关论文
共 50 条
  • [21] Diagnostic accuracy of ultrasonography in acute lateral ankle ligament injury: A systematic review and meta-analysis
    Kocsis, Koppany
    Stubnya, Bence
    Vancsa, Szilard
    Koi, Tamas
    Kovacs, Norbert
    Hergar, Luca
    Hetthessy, Judit
    Holnapy, Gergely
    Hegyi, Peter
    Pap, Karoly
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55
  • [22] The Diagnostic Accuracy of Bedside Ocular Ultrasonography for the Diagnosis of Retinal Detachment: A Systematic Review and Meta-analysis
    Vrablik, Michael E.
    Snead, Gregory R.
    Minnigan, Hal J.
    Kirschner, Jonathan M.
    Emmett, Thomas W.
    Seupaul, Rawle A.
    ANNALS OF EMERGENCY MEDICINE, 2015, 65 (02) : 199 - 203
  • [23] Diagnostic accuracy of bowel ultrasonography in patients with inflammatory bowel disease: a systematic review and meta-analysis
    Malik, Sheza
    Venugopalan, Sruthi
    Tenorio, Bettina Gabrielle
    Khan, Shahab R.
    Loganathan, Priyadarshini
    Navaneethan, Udayakumar
    Mohan, Babu P.
    ANNALS OF GASTROENTEROLOGY, 2024, 37 (01): : 54 - 63
  • [24] Diagnostic accuracy of transvaginal sonography for detecting parametrial involvement in women with deep endometriosis: systematic review and meta-analysis
    Guerriero, S.
    Martinez, L.
    Gomez, I.
    Pascual, M. A.
    Ajossa, S.
    Pagliuca, M.
    Alcazar, J. L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2021, 58 (05) : 669 - 676
  • [25] Accuracy of Ultrasonography for the Diagnosis of Carpal Tunnel Syndrome: A Systematic Review and Meta-Analysis
    Torres-Costoso, Ana
    Martinez-Vizcaino, Vicente
    Alvarez-Bueno, Celia
    Ferri-Morales, Asuncion
    Cavero-Redondo, Ivan
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2018, 99 (04): : 758 - 765
  • [26] Accuracy of Lung Ultrasonography for Diagnosis of Heart Failure; a Systematic Review and Meta-analysis
    Rahmani, Erfan
    Farrokhi, Masoud
    Farrokhi, Mehrdad
    Nouri, Shadi
    Fard, Atousa Moghadam
    Hoorshad, Behnam
    Atighi, Ramin
    Ghadirzadeh, Erfan
    Tajik, Michael
    Afshang, Habibollah
    Naseri, Aida
    Asoudehfard, Mohadeseh
    Kojidi, Shiva Samami
    Ebnemehdi, Arsham
    Rezaei, Mehdi
    Daneshvar, Maziar
    Makhmalbaf, Amirali
    Khodaei, Sepideh Hassanpour
    Farsi, Shirin
    Rad, Saber Barazandeh
    Nozari, Fateme
    Rezaei, Pouya
    Babapour, Negar
    Delavar, Salman
    Goodarzy, Babak
    Lahijan, Lida Zare
    Mohammadzadeh, Sanam
    Mehran, Helena
    Gheibi, Fatemeh
    Shemshadigolafzani, Ramtin
    Dalvandi, Behnaz
    Abderam, Amir
    ARCHIVES OF ACADEMIC EMERGENCY MEDICINE, 2025, 13 (01)
  • [27] Diagnostic accuracy of ultrasonography in relation to salivary gland biopsy in Sjögren's syndrome: a systematic review with meta-analysis
    Martins, Fernanda B.
    Oliveira, Millena B.
    Oliveira, Leandro M.
    Lourenco, Alan Grupioni
    Paranhos, Luiz Renato
    Motta, Ana Carolina F.
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (02) : 91 - 102
  • [28] The accuracy of methods for determining the internal length of a nasogastric tube in adult patients: a systematic review
    Torsy, Tim
    van Noort, Harm H. J.
    Taylor, Stephen
    Eriksson, Mats
    Verhaeghe, Sofie
    Beeckman, Dimitri
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2022, 116 (03) : 798 - 811
  • [29] Nasogastric tube versus postpyloric tube feeding for critical illness: A systematic review and meta-analysis
    Li, Liru
    Huang, Jie
    ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION, 2024, 33 (03) : 283 - 297
  • [30] Diagnostic accuracy of artificial intelligence for detecting gastrointestinal luminal pathologies: A systematic review and meta-analysis
    Parkash, Om
    Siddiqui, Asra Tus Saleha
    Jiwani, Uswa
    Rind, Fahad
    Padhani, Zahra Ali
    Rizvi, Arjumand
    Hoodbhoy, Zahra
    Das, Jai K.
    FRONTIERS IN MEDICINE, 2022, 9