Corrosive degradation and failure of vertical furnace wall tubes of a boiler

被引:16
作者
Chattoraj, I [1 ]
Das, SK
Ravikumar, B
Bhattacharya, DK
机构
[1] Natl Met Lab, CRP Div, Jamshedpur 831007, Bihar, India
[2] Natl Met Lab, MTC Div, Jamshedpur 831007, Bihar, India
关键词
boiler failures; corrosion; decarburization; overheating;
D O I
10.1016/S1350-6307(97)00015-0
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The failures of vertical furnace wall tubes of a co-generation boiler have been investigated. The thinned section failures, often accompanied by buckling prior to failure, were found to be due to acid attack as a consequence of "hideout". The local corrosion and consequent thick and non-protective iron-oxide deposition at the sites of attack produced hot spots, which is evident from the microstructure of those regions. Decarburization by hydrogen generated during the corrosion process also contributed to the loss in strength of the material. The possibility of "alkali attack" as opposed to acid attack was ruled out by the various findings of this investigation. (C) 1997 Published by Elsevier Science Ltd.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 7 条
[1]   Crevice attack of a boiler steam drum [J].
Chattoraj, I ;
Joarder, A ;
Bhattamishra, AK ;
Bhattacharya, DK ;
Ghosh, RN .
CANADIAN METALLURGICAL QUARTERLY, 1997, 36 (02) :143-148
[2]   IDENTIFICATION OF THE CORROSION MECHANISM IN A BOILER DRUM BY CORROSION PRODUCT ANALYSIS [J].
CHATTORAJ, I ;
BHATTAMISHRA, AK ;
JOARDER, A ;
BHATTACHARYA, DK .
ANTI-CORROSION METHODS AND MATERIALS, 1995, 42 (03) :4-6
[3]  
FREEDMAN AJ, 1984, MATER PERFORMANCE, V23, P9
[4]  
LITTLER DJ, 1992, MODERN POWER STATION, VE, P157
[5]  
MONTRONE ED, 1989, MATER PERFORMANCE, V28, P49
[6]  
PRT RD, 1984, MATER PERFORMANCE, V23, P45
[7]   MOSSBAUER AND X-RAY-DIFFRACTION PHASE-ANALYSIS OF RUSTS FROM ATMOSPHERIC TEST SITES WITH DIFFERENT ENVIRONMENTS IN SWEDEN [J].
SINGH, AK ;
ERICSSON, T ;
HAGGSTROM, L ;
GULLMAN, J .
CORROSION SCIENCE, 1985, 25 (10) :931-945