High-Precision Electrical Impedance Tomography Data Acquisition System for Brain Imaging

被引:100
|
作者
Shi, Xuetao [1 ]
Li, Weichen [1 ]
You, Fusheng [1 ]
Huo, Xuyang [2 ]
Xu, Canhua [1 ]
Ji, Zhenyu [1 ]
Liu, Ruigang [1 ]
Liu, Benyuan [1 ]
Li, Yandong [1 ]
Fu, Feng [1 ]
Dong, Xiuzhen [1 ]
机构
[1] Fourth Mil Med Univ, Sch Biomed Engn, Dept Biomed Engn, Xian 710032, Shaanxi, Peoples R China
[2] Jilin Med Coll, Fac Biomed Engn, Jilin 132013, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrical impedance; brain imaging; data acquisition; imaging monitoring; EIT SYSTEM; CALIBRATION; ELECTRODES; DESIGN; EEG;
D O I
10.1109/JSEN.2018.2836336
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In electrical impedance tomography (EIT), it is difficult to obtain the intracranial impedance due to the highly resistive skull enclosing the brain. Therefore, a high-precision data acquisition system is required for brain EIT. In this paper, we used a high-precision digital synthesis method and a digital demodulation technique with high noise immunity to eliminate random errors. Moreover, we focused on two problems encountered during EIT data acquisition: 1) the shunt effect on the excitation current due to the distributed capacitance between electrodes and ground and 2) high common-mode voltages in the boundary measurements. We designed a new electrode interface to reduce the influence of the distributed capacitance and a programmable current source to accurately compensate for the excited current. We also proposed a new voltmeter circuit with improved CMRR. Overall, this EIT data acquisition system can produce a programmable current with SNR greater than 89 dB. It can also measure the voltage difference precisely with CMRR higher than 75 dB with a 1-k Omega impedance imbalance. The results on a calibration model show that this system has a high SNR of 83 dB and a low reciprocity error of 0.125%. In addition, EIT imaging results were acquired using a brain physical phantom. The system can detect small disturbances of 0.35% in volume (1.99% of the cross-sectional area) and 17% in resistivity. Experiments on healthy volunteers also suggest that small intracranial impedance variations due to temporary occlusion and reperfusion of the unilateral carotid artery may be monitored by the system.
引用
收藏
页码:5974 / 5984
页数:11
相关论文
共 50 条
  • [31] Imaging slow brain activity during neocortical and hippocampal epileptiform events with electrical impedance tomography
    Hannan, Sana
    Aristovich, Kirill
    Faulkner, Mayo
    Avery, James
    Walker, Matthew C.
    Holder, David S.
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (01)
  • [32] A research of a high precision multi-channel data acquisition system
    Zhong Ling-na
    Tang Xiao-ping
    Yan Wei
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: MICRO/NANO OPTICAL IMAGING TECHNOLOGIES AND APPLICATIONS, 2013, 8911
  • [33] Design of High Precision Synchronous Data Acquisition System with Temperature Compensation
    Wang Kuan
    Qi Xiaopeng
    Li Panwen
    PROCEEDINGS OF 2020 IEEE INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND INFORMATION SYSTEMS (ICAIIS), 2020, : 235 - 238
  • [34] A Low-Cost Portable Wireless Multi-frequency Electrical Impedance Tomography System
    Singh, Gurmeet
    Anand, Sneh
    Lall, Brejesh
    Srivastava, Anurag
    Singh, Vaneet
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (03) : 2305 - 2320
  • [35] Accounting for erroneous electrode data in electrical impedance tomography
    Adler, A
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 227 - 238
  • [36] Development of a Miniaturized, Low-Cost Electrical Impedance Tomography System
    Sun, Nan
    Yang, Dan
    Xu, Bin
    Li, Shijun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [37] Design and application of data acquisition system of electrical capacitance tomography based on embedded structure
    He Shi-Jun
    Han Yu-hui
    Wang Hua-xiang
    Proceedings of 2005 Chinese Control and Decision Conference, Vols 1 and 2, 2005, : 2133 - 2135
  • [38] Development of The Data Acquisition System for The 32-Channel Electrical Capacitance Volume Tomography
    Yusuf, Arba'i
    Widada, Wahyu
    Warsito, W.
    2011 IEEE REGION 10 CONFERENCE TENCON 2011, 2011, : 326 - 329
  • [39] BEATS: An Open-Source, High-Precision, Multi-Channel EEG Acquisition Tool System
    Zou, Bing
    Zheng, Yubo
    Shen, Mu
    Luo, Yingying
    Li, Lei
    Zhang, Lin
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2022, 16 (06) : 1287 - 1298
  • [40] Static imaging of the electrical impedance tomography on cylinder physical phantom
    Liu, Ruigang
    Fu, Feng
    You, Fusheng
    Shi, Xuetao
    Dong, Xiuzhen
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S1381 - S1388