Sensory perturbations using suture and sutureless repair of transected median nerve in rats

被引:14
作者
Shaikh, Sumaiya [1 ]
Shortland, Peter [2 ]
Lauto, Antonio [2 ]
Barton, Matthew [1 ]
Morley, John W. [1 ]
Mahns, David A. [1 ]
机构
[1] Univ Western Sydney, Sch Med, Locked Bag 1797, Penrith, NSW 2751, Australia
[2] Univ Western Sydney, Sch Sci & Hlth, Penrith, NSW 2751, Australia
关键词
Bilateral hypersensitivity; Cold allodynia; mechanical allodynia; nerve repair; pain; regeneration; MIRROR-IMAGE PAIN; HUMAN HAIRY SKIN; COLD ALLODYNIA; ADULT-RATS; C FIBERS; IN-VIVO; INJURY; REGENERATION; HYPERALGESIA; AFFERENTS;
D O I
10.3109/08990220.2016.1142438
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The effects of changes to cold, mechanical, and heat thresholds following median nerve transection with repair by sutures (Su) or Rose Bengal adhesion (RA) were compared to sham-operated animals. Both nerve-injured groups showed a transient, ipsilateral hyposensitivity to mechanical and heat stimuli followed by a robust and long-lasting hypersensitivity (6-7 weeks) with gradual recovery towards pre-injury levels by 90 days post-repair. Both tactile and thermal hypersensitivity were seen in the contralateral limb that was similar in onset but differed in magnitude and resolved more rapidly compared to the injured limb. Prior to injury, no animals showed any signs of aversion to cold plate temperatures of 4-16 degrees C. After injury, animals showed cold allodynia, lasting for 7 weeks in RA-repaired rats before recovering towards pre-injury levels, but were still present at 12 weeks in Su-repaired rats. Additionally, sensory recovery in the RA group was faster compared to the Su group in all behavioural tests. Surprisingly, sham-operated rats showed similar bilateral behavioural changes to all sensory stimuli that were comparable in onset and magnitude to the nerve-injured groups but resolved more quickly compared to nerve-injured rats. These results suggest that nerve repair using a sutureless approach produces an accelerated recovery with reduced sensorimotor disturbances compared to direct suturing. They also describe, for the first time, that unilateral forelimb nerve injury produces mirror-image-like sensory perturbations in the contralateral limb, suggesting that the contralateral side is not a true control for sensory testing. The potential mechanisms involved in this altered behaviour are discussed.
引用
收藏
页码:20 / 28
页数:9
相关论文
共 58 条
[51]   Bioartificial reconstruction of peripheral nerves using the rat median nerve model [J].
Sinis, Nektarios ;
Kraus, Armin ;
Drakotos, Dimitris ;
Doser, Michael ;
Schlosshauer, Burkhard ;
Mueller, Hans-Werner ;
Skouras, Emmanouil ;
Bruck, Johannes C. ;
Werdin, Frank .
ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2011, 193 (04) :341-346
[52]   Different immune cells mediate mechanical pain hypersensitivity in male and female mice [J].
Sorge, Robert E. ;
Mapplebeck, Josiane C. S. ;
Rosen, Sarah ;
Beggs, Simon ;
Taves, Sarah ;
Alexander, Jessica K. ;
Martin, Loren J. ;
Austin, Jean-Sebastien ;
Sotocinal, Susana G. ;
Chen, Di ;
Yang, Mu ;
Shi, Xiang Qun ;
Huang, Hao ;
Pillon, Nicolas J. ;
Bilan, Philip J. ;
Tu, YuShan ;
Klip, Amira ;
Ji, Ru-Rong ;
Zhang, Ji ;
Salter, Michael W. ;
Mogil, Jeffrey S. .
NATURE NEUROSCIENCE, 2015, 18 (08) :1081-+
[53]   Microglia and intractable chronic pain [J].
Tsuda, Makoto ;
Beggs, Simon ;
Salter, Michael W. ;
Inoue, Kazuhide .
GLIA, 2013, 61 (01) :55-61
[54]   Methods for the experimental functional assessment of rat sciatic nerve regeneration [J].
Varejao, ASP ;
Melo-Pinto, P ;
Meek, MF ;
Filipe, VA ;
Bulas-Cruz, J .
NEUROLOGICAL RESEARCH, 2004, 26 (02) :186-194
[55]  
Watkins LR, 2001, TRENDS NEUROSCI, V24, P450, DOI 10.1016/S0166-2236(00)01854-3
[56]  
WIESENFELDHALLIN Z, 1989, EXP BRAIN RES, V76, P88
[57]   A novel rat forelimb model of neuropathic pain produced by partial injury of the median and ulnar nerves [J].
Yi, Hanju ;
Kim, Myung Ah ;
Back, Seung Keun ;
Eun, Jong Shin ;
Na, Heung Sik .
EUROPEAN JOURNAL OF PAIN, 2011, 15 (05) :459-466
[58]  
Zotterman Y, 1939, J PHYSIOL-LONDON, V95, P1