Simultaneous Determination of Inorganic Cations and Anions in Microchip Electrophoresis Using High-voltage Relays

被引:8
作者
Huang, Zhe [1 ,2 ]
Yang, Mingpeng [1 ,2 ]
You, Hui [1 ,2 ]
Xie, Yang [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Intelligent Machines, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Instruments Sci & Engn, Hefei 230026, Anhui, Peoples R China
关键词
Microchip electrophoresis; capacitively coupled contactless conductivity detection; simultaneous determination; high-voltage relay; cation; anion; CONTACTLESS CONDUCTIVITY DETECTION; CAPILLARY-ELECTROPHORESIS; ELECTRODES; CHIPS;
D O I
10.2116/analsci.18P022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and simple method for the simultaneous determination of cations and anions by microchip electrophoresis with capacitively coupled contactless conductivity detection (ME-(CD)-D-4) is described. The best analytical performance was found by applying a sinusoidal wave with 800 kHz frequency and 20 V,, amplitude. An optimized background electrolyte (BGE) composed of 20 mM His/MES and 0.01 mM CTAB was chosen for the simultaneous analysis. Samples containing K+, Na+, and Li+ as the cations and Cl-, F- and PO43- as anions were analyzed simultaneously in a single run (within 3 min). The reproducibility obtained by the method was compared with those obtained in previous studies that had employed simultaneous analysis of anions and cations by ME-(CD)-D-4. The proposed simultaneous determination method is inexpensive, simple, fast, easy to operate, and offers a high degree of integration.
引用
收藏
页码:801 / 805
页数:5
相关论文
共 18 条
[1]   Surfactant-induced electroosmotic flow in microfluidic capillaries [J].
Azadi, Glareh ;
Tripathi, Anubhav .
ELECTROPHORESIS, 2012, 33 (14) :2094-2101
[2]  
Costa E. T. d., 2012, ELECTROPHORESIS, V33, P2650
[3]   3D printing of microfluidic devices with embedded sensing electrodes for generating and measuring the size of microdroplets based on contactless conductivity detection [J].
Duarte, Lucas C. ;
Chagas, Cyro L. S. ;
Ribeiro, Luiz E. B. ;
Coltro, Wendell K. T. .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 251 :427-432
[4]   Monitoring of nitrite, nitrate, chloride and sulfate in environmental samples using electrophoresis microchips coupled with contactless conductivity detection [J].
Freitas, Camilla Benevides ;
Moreira, Roger Cardoso ;
de Oliveira Tavares, Maria Gizelda ;
Coltro, Wendell K. T. .
TALANTA, 2016, 147 :335-341
[5]   Polymeric Microchip for the Simultaneous Determination of Anions and Cations by Hydrodynamic Injection Using a Dual-Channel Sequential Injection Microchip Electrophoresis System [J].
Gaudry, Adam J. ;
Nai, Yi Heng ;
Guij, Rosanne M. ;
Breadmore, Michael C. .
ANALYTICAL CHEMISTRY, 2014, 86 (07) :3380-3388
[6]   In-plane alloy electrodes for capacitively coupled contactless conductivity detection in poly(methylmethacrylate) electrophoretic chips [J].
Gaudry, Adam J. ;
Breadmore, Michael C. ;
Guijt, Rosanne M. .
ELECTROPHORESIS, 2013, 34 (20-21) :2980-2987
[7]  
Duong HA, 2015, ENVIRON SCI-PROC IMP, V17, P1941, DOI [10.1039/c5em00362h, 10.1039/C5EM00362H]
[8]   Simultaneous determination of chromium(III) and Chromium(VI) in aqueous solution by capillary electrophoresis with on-column UV-VIS detection [J].
Jung, GY ;
Kim, YS ;
Lim, HB .
ANALYTICAL SCIENCES, 1997, 13 (03) :463-467
[9]   Application of capacitively coupled contactless conductivity as an external detector for zone electrophoresis in poly(dimethylsiloxane) chips [J].
Koczka, Peter I. ;
Bodoki, Ede ;
Gaspar, Attila .
ELECTROPHORESIS, 2016, 37 (03) :398-405
[10]   A simplified poly(dimethylsiloxane) capillary electrophoresis microchip integrated with a low-noise contactless conductivity detector [J].
Liu, Benyan ;
Zhang, Yi ;
Mayer, Dirk ;
Krause, Hans-Joachim ;
Jin, Qinghui ;
Zhao, Jianlong ;
Offenhaeusser, Andreas .
ELECTROPHORESIS, 2011, 32 (6-7) :699-704