Mechanism of mass transfer from bubbles in dispersions - Part II: Mass transfer coefficients in stirred gas-liquid reactor and bubble column

被引:65
作者
Linek, V [1 ]
Kordac, M [1 ]
Moucha, T [1 ]
机构
[1] Prague Inst Chem Technol, Dept Chem Engn, CR-16628 Prague 6, Czech Republic
关键词
gas-liquid contactor; bubble column; agitated vessel; mass transfer coefficient; viscosity; surfactants;
D O I
10.1016/j.cep.2004.05.009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Experimental data on the average mass transfer liquid film coefficient (k(L)) in an aerated tank stirred by Rushton turbine and in bubble column are presented. Liquid media were used as 0.8M sodium sulphite solution, pure or with the addition of Sokrat 44 (copolymer of acrylonitrile and acrylic acid) or short-fiber carboxymethylcellulose (CMC) for the Newtonian and long-fiber CMC for the non-Newtonian viscosity enhancement and ocenol (cis-9-octadecen-1-ol) or polyethylenglycol (PEG) 1000 for surface tension change. Volumetric mass transfer coefficient (k(L)a) and specific interfacial area (a) were measured by the Danckwerts' plot method. Coefficients kL measured by pure oxygen absorption in pure sulphite solution and Newtonian viscous liquids are well fitted by the "eddy" model in the form of k(L) = 0.448 (ev/p)(0.25) (D/v)(0.5) with a mean deviation of 20%. Surface-active agents (ocenol and PEG) and non-Newtonian additive (long-fiber CMC) reduced k(L) value significantly but their effect was not described satisfactorily neither by surface tension nor by surface pressure. It is shown that the decisive quantity to correlate k(L) in the stirred tank and bubble column is power dissipated in the liquid phase rather than the bubble diameter and the slip velocity. Absorption of air did not yield correct kL data, which did not depend on or slightly decreased with increasing power. This is due to the application of an improper gas phase mixing model for absorption data evaluation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 130
页数:10
相关论文
共 32 条
[1]   Gas-liquid mass transfer coefficient in stirred tanks interpreted through bubble contamination kinetics [J].
Alves, SS ;
Maia, CI ;
Vasconcelos, JMT .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2004, 43 (07) :823-830
[2]   A comparative study of gas hold-up, bubble size, interfacial area and mass transfer coefficients in stirred gas-liquid reactors and bubble columns [J].
Bouaifi, M ;
Hebrard, G ;
Bastoul, D ;
Roustan, M .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2001, 40 (02) :97-111
[3]   Bubble size and mass transfer coefficients in dual-impeller agitated reactors [J].
Bouaifi, MI ;
Roustan, M .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1998, 76 (03) :390-397
[4]   THE CONTINUOUS PHASE HEAT AND MASS-TRANSFER PROPERTIES OF DISPERSIONS [J].
CALDERBANK, PH ;
MOOYOUNG, MB .
CHEMICAL ENGINEERING SCIENCE, 1961, 16 (1-2) :39-54
[5]   DETERMINATION OF MASS TRANSFER COEFFICIENTS AND INTERFACIAL AREAS IN GAS-LIQUID CONTACTING SYSTEMS [J].
DILLON, GB ;
HARRIS, IJ .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1966, 44 (06) :307-&
[6]  
FIGUEIREDO MM, 1979, CHEM ENG SCI, V34, P1333
[7]  
Frossling N., 1938, Gerlands Beitrage Zur Geophys, V52, P170
[8]   MASS-TRANSFER COEFFICIENTS IN MECHANICALLY AGITATED GAS-AQUEOUS ELECTROLYTE DISPERSIONS [J].
HASSAN, ITM ;
ROBINSON, CW .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1980, 58 (02) :198-205
[9]   THEORETICAL PREDICTION OF VOLUMETRIC MASS-TRANSFER COEFFICIENTS IN BUBBLE-COLUMNS FOR NEWTONIAN AND NON-NEWTONIAN FLUIDS [J].
KAWASE, Y ;
HALARD, B ;
MOOYOUNG, M .
CHEMICAL ENGINEERING SCIENCE, 1987, 42 (07) :1609-1617
[10]   LIQUID-PHASE MASS-TRANSFER COEFFICIENTS IN BIOREACTORS [J].
KAWASE, Y ;
HALARD, B ;
MOOYOUNG, M .
BIOTECHNOLOGY AND BIOENGINEERING, 1992, 39 (11) :1133-1140