A novel antibody immobilization and its application in immunoaffinity chromatography

被引:5
作者
Zhang, Shuoyao [1 ]
Wang, Junqing [1 ]
Li, Dawei [1 ]
Huang, Juan [2 ]
Yang, Hong [2 ]
Deng, Anping [1 ]
机构
[1] Sichuan Univ, Coll Chem, Chengdu 610064, Peoples R China
[2] Sichuan Univ, W China Sch Pharm, Chengdu 610041, Peoples R China
基金
中国国家自然科学基金;
关键词
antibody immobilization; immunoaffinity chromatography; Cu(II)-embedded polymer; solid phase extraction; clenbuterol; PERFORMANCE LIQUID-CHROMATOGRAPHY; PRION PROTEIN; SAMPLE PREPARATION; DETECTION SYSTEM; WATER SAMPLES; BISPHENOL-A; HUMAN URINE; EXTRACTION; PURIFICATION; AFFINITY;
D O I
10.1016/j.talanta.2010.05.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel antibody immobilization and its application in immunoaffinity chromatography (IAC) were presented. Using acrylamide (AM) as monomer, ethylene glycoldimethacrylate (EGDMA) as cross-linker and bulk polymerization as synthetic method, we prepared a polymer in which the Cu(II) was embedded. The Cu(II)-embedded polymer was tested for its binding with protein. It was found that Cu(II)-embedded polymer displayed a strong binding with bovine serum albumin (BSA). At 80% of methanol, no BSA was released from Cu(II)-embedded polymer. The Cu(II)-embedded polymer was then used as a novel solid support for antibody immobilization. IAC column was prepared by immobilizing polyclonal antibody (pAb) against clenbuterol (CL) on Cu(II)-embedded polymer and packing the Cu(II)-embedded polymer-pAb into a common solid phase extraction (SPE) cartridge. Under optimal extraction conditions, the IAC column was characterized in terms of maximum binding capacity for target analyte, extraction efficiency and reusability. It was revealed that, for IAC column packed with 0.1 g of solid support immobilized with antibody, the maximum capacity for CL was 616 ng: the extraction recoveries of the column for CL from three spiked food samples were 84.4-95.2% with relative standard deviation (RSD) of 9.3-15.5%; after more than 30 times repeated usage, there was not significant loss of specific recognition. The results demonstrated the feasibility of the prepared IAC column for CL extraction. The proposed antibody immobilization method exhibiting the properties of simplicity, low cost, strong binding for target analyte, no leaching of antibody, etc., would be a very useful tool applied in the field of IAC. (C) 010 Elsevier B.V. All rights reserved.
引用
收藏
页码:704 / 709
页数:6
相关论文
共 26 条
[1]   Spongiform encephalopathies - B lymphocytes and neuroinvasion [J].
Brown, P .
NATURE, 1997, 390 (6661) :662-663
[2]   Quantification of testosterone and epitestosterone in biological samples by capillary electrophoresis with immunoaffinity extraction [J].
Chen, Hong-Xu ;
Deng, Qin-Pei ;
Zhang, Li-Wei ;
Zhang, Xin-Xiang .
TALANTA, 2009, 78 (02) :464-470
[3]   Development and application of immunoaffinity column chromatography for atrazine in complex sample media [J].
Chuang, Jane C. ;
Van Emon, Jeanette M. ;
Jones, Randy ;
Durnford, Joyce ;
Lordo, Robert A. .
ANALYTICA CHIMICA ACTA, 2007, 583 (01) :32-39
[4]   On-line coupling of sol-gel-generated immunoaffinity columns with high-performance liquid chromatography [J].
Cichna, M ;
Markl, P ;
Knopp, D ;
Niessner, R .
JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) :51-58
[5]   Thermodynamic and Voltammetric Characterization of the Metal Binding to the Prion Protein: Insights into pH Dependence and Redox Chemistry [J].
Davies, Paul ;
Marken, Frank ;
Salter, Simon ;
Brown, David R. .
BIOCHEMISTRY, 2009, 48 (12) :2610-2619
[6]   Survey of recent advances in analytical applications of immunoaffinity chromatography [J].
Hage, DS .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 715 (01) :3-28
[7]   Development of a polyclonal indirect ELISA with sub-ng g-1 sensitivity for the analysis of clenbuterol in milk, animal feed, and liver samples and a small survey of residues in retail animal products [J].
He, L. ;
Pu, C. ;
Yang, H. ;
Zhao, D. ;
Deng, A. -P. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (08) :1153-1161
[8]   Immuno-based sample preparation for trace analysis [J].
Hennion, MC ;
Pichon, V .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :29-52
[9]   Determination of vitamin B12 in food products and in premixes by reversed-phase high performance liquid chromatography and immunoaffinity extraction [J].
Heudi, O ;
Kilinç, T ;
Fontannaz, P ;
Marley, E .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :63-68
[10]   Thermodynamic studies of the solvent effects in chromatography on molecularly imprinted polymers. 3. Nature of the organic mobile phase [J].
Kim, HJ ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2496-2504