Closed - Loop Calibration for Optical See-Through Near Eye Display with Infinity Focus

被引:8
作者
Fontana, Umberto [1 ]
Cutolo, Fabrizio [2 ]
Cattari, Nadia [1 ]
Ferrari, Vincenzo [2 ]
机构
[1] Univ Pisa, EndoCAS Ctr, Dept Translat Res & New Technol Med & Surg, Pisa, Italy
[2] Univ Pisa, EndoCAS Ctr, Dept Informat Engn, Pisa, Italy
来源
ADJUNCT PROCEEDINGS OF THE 2018 IEEE INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY (ISMAR) | 2018年
关键词
Near-Eye Display; Optical See-through; Calibration; Eye Position;
D O I
10.1109/ISMAR-Adjunct.2018.00033
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In wearable augmented reality systems, optical see-through near-eye displays (OST NEDs) based on waveguides are becoming a standard as they are generally preferred over solutions based on semi-reflective curved mirrors. This is mostly due to their ability to ensure reduced image distortion and sufficiently wide eye motion box without the need for bulky optical and electronics components to be placed in front of the user's face and/or onto the user's line of sight. In OST head-mounted displays (HMDs) the user's own view is augmented by optically combining it with the virtual content rendered on a two-dimensional (2D) microdisplay. For achieving a perfect combination of the light field in the real 3D world and the computer-generated 2D graphics projected on the display, an accurate alignment between real and virtual content must be yielded at the level of the NED imaging plane. To this end, we must know the exact position of the user's eyes within the HMD reference system. State-of-the-art methods models the eye-NED system as an off-axis pinhole camera model, and therefore include the contribution of the eyes' positions into the modelling of the intrinsic matrix of the eye-NED. In this paper, we will describe a method for robustly calibrating OST NEDs that explicitly ignore this assumption. To verify the accuracy of our method, we conducted a set of experiments in a setup comprising a commercial waveguide-based OST NED and a camera in place of the user's eye. We tested a set of different camera (or eye) positions within the eye box of the NED. The obtained results demonstrate that the proposed method yields accurate results in terms of real-to-virtual alignment, regardless of the position of the eyes within the eye box of the NEDs (Figure 1). The achieved viewing accuracy was of 1.85 +/- 1.37 pixels.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 17 条
[1]  
[Anonymous], 2003, Multiple view geometry in computer vision
[2]   Perspective Preserving Solution for Quasi-Orthoscopic Video See-Through HMDs [J].
Cutolo, Fabrizio ;
Fontana, Umberto ;
Ferrari, Vincenzo .
TECHNOLOGIES, 2018, 6 (01)
[3]   Hybrid Video/Optical See-Through HMD [J].
Cutolo, Fabrizio ;
Fontana, Umberto ;
Carbone, Marina ;
D'Amato, Renzo ;
Ferrari, Vincenzo .
ADJUNCT PROCEEDINGS OF THE 2017 IEEE INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY (ISMAR-ADJUNCT), 2017, :52-57
[4]   A new head-mounted display-based augmented reality system in neurosurgical oncology: a study on phantom [J].
Cutolo, Fabrizio ;
Meola, Antonio ;
Carbone, Marina ;
Sinceri, Sara ;
Cagnazzo, Federico ;
Denaro, Ennio ;
Esposito, Nicola ;
Ferrari, Mauro ;
Ferrari, Vincenzo .
COMPUTER ASSISTED SURGERY, 2017, 22 (01) :39-53
[5]   Robust and Accurate Algorithm for Wearable Stereoscopic Augmented Reality with Three Indistinguishable Markers [J].
Cutolo, Fabrizio ;
Freschi, Cinzia ;
Mascioli, Stefano ;
Parchi, Paolo D. ;
Ferrari, Mauro ;
Ferrari, Vincenzo .
ELECTRONICS, 2016, 5 (03)
[6]   Application of a New Wearable Augmented Reality Video See-Through Display to Aid Percutaneous Procedures in Spine Surgery [J].
Cutolo, Fabrizio ;
Carbone, Marina ;
Parchi, Paolo D. ;
Ferrari, Vincenzo ;
Lisanti, Michele ;
Ferrari, Mauro .
AUGMENTED REALITY, VIRTUAL REALITY, AND COMPUTER GRAPHICS, PT II, 2016, 9769 :43-54
[7]   Practical solutions for calibration of optical see-through devices [J].
Genc, Y ;
Tuceryan, M ;
Navab, N .
INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY, PROCEEDINGS, 2002, :169-175
[8]   Spatial calibration of an optical see-through head-mounted display [J].
Gilson, Stuart J. ;
Fitzgibbon, Andrew W. ;
Glennerster, Andrew .
JOURNAL OF NEUROSCIENCE METHODS, 2008, 173 (01) :140-146
[9]  
Grubert J., 2017, IEEE T VISUALIZATION
[10]  
Itoh Y, 2014, 2014 IEEE SYMPOSIUM ON 3D USER INTERFACES (3DUI), P75, DOI 10.1109/3DUI.2014.6798846