Incidence and predictors of implantable cardioverter-defibrillator therapy and its complications in idiopathic ventricular fibrillation patients

被引:22
作者
Blom, Lennart J. [1 ]
Visser, Marloes [1 ]
Christiaans, Imke [2 ]
Scholten, Marcoen F. [3 ]
Bootsma, Marianne [4 ]
van den Berg, Maarten P. [5 ]
Yap, Sing-Chien [6 ]
van der Heijden, Jeroen F. [1 ]
Doevendans, Pieter A. [1 ,7 ,8 ]
Loh, Peter [1 ]
Postema, Pieter G. [9 ]
Barge-Schaapsveld, Daniela Q. [10 ]
Hofman, Nynke [2 ]
Volders, Paul G. A. [11 ]
Wilde, Arthur A. [6 ]
Hassink, Rutger J. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiol, Utrecht, Netherlands
[2] AMC, Dept Cardiogenet, Amsterdam, Netherlands
[3] Med Spectrum Twente, Dept Cardiol, Thoraxctr Twente, Enschede, Netherlands
[4] Leiden Univ, Dept Cardiol, Med Ctr, Leiden, Netherlands
[5] Univ Med Ctr Groningen, Dept Cardiol, Groningen, Netherlands
[6] Univ Med Ctr Rotterdam, Dept Cardiol, Rotterdam, Netherlands
[7] Cent Mil Hosp, Utrecht, Netherlands
[8] Netherlands Heart Inst ICIN, Utrecht, Netherlands
[9] Amsterdam UMC, Dept Clin & Expt Cardiol, Heart Ctr, Amsterdam, Netherlands
[10] Leiden Univ, Dept Clin Genet, Med Ctr, Leiden, Netherlands
[11] Maastricht Univ, Med Ctr, Cardiovasc Res Inst Maastricht CARIM, Dept Cardiol, Maastricht, Netherlands
来源
EUROPACE | 2019年 / 21卷 / 10期
关键词
Idiopathic ventricular fibrillation; Ventricular arrhythmia; Implantable cardioverter-defibrillator; Implantable cardioverter-defibrillator therapy; primary electrical disease; PROLONGED PR INTERVAL; TERM-FOLLOW-UP; MANAGEMENT; ABLATION; OUTCOMES;
D O I
10.1093/europace/euz151
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Idiopathic ventricular fibrillation (IVF) is a rare cause of sudden cardiac arrest. Implantable cardioverter-defibrillator (ICD) implantation is currently the only treatment option. Limited data are available on the prevalence and complications of ICD therapy in these patients. We sought to investigate ICD therapy and its complications in patients with IVF. Methods and results Patients were selected from a national registry of IVF patients. Patients in whom no underlying diagnosis was found during follow-up were eligible for inclusion. Recurrence of ventricular arrhythmia (VA) was derived from medical and ICD records, electrogram records of ICD therapies were used to differentiate between appropriate or inappropriate interventions. Independent predictors for appropriate ICD shock were calculated using cox regression. In 217 IVF patients, recurrence of sustained VAs occurred in 66 patients (30%) during a median follow-up period of 6.1 years. Ten patients died (4.6%). Thirty-eight patients (17.5%) experienced inappropriate ICD therapy, and 32 patients (14.7%) had device-related complications. Symptoms before cardiac arrest [hazard ratio (HR): 2.51, 95% confidence interval (CI): 1.48-4.24], signs of conduction disease (HR: 2.27, 95% CI: 1.15-4.47), and carrier of the DPP6 risk haplotype (HR: 3.24, 1.70-6.17) were identified as independent predictors of appropriate shock occurrence. Conclusion Implantable cardioverter-defibrillator therapy is an effective treatment in IVF, treating recurrences of potentially lethal VAs in approximately one-third of patients during long-term follow-up. However, device-related complications and inappropriate shocks were also frequent. We found significant predictors for appropriate ICD therapy. This may imply that these patients require additional management to prevent recurrent events.
引用
收藏
页码:1519 / 1526
页数:8
相关论文
共 50 条
[21]   Inappropriate Implantable Cardioverter-Defibrillator Shocks Incidence, Predictors, and Impact on Mortality [J].
van Rees, Johannes B. ;
Borleffs, C. Jan Willem ;
de Bie, Mihaly K. ;
Stijnen, Theo ;
van Erven, Lieselot ;
Bax, Jeroen J. ;
Schalij, Martin J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (05) :556-562
[22]   Predictors of Implantable Cardioverter-Defibrillator Use in Patients with Ischemic Cardiomyopathy [J].
Kelly, Ryan ;
Buth, Karen J. ;
Heimrath, Olivier ;
Basta, Magdy ;
Legare, Jean-Francois .
OPEN CARDIOVASCULAR MEDICINE JOURNAL, 2010, 4 :206-213
[23]   Predictors of ventricular tachyarrhythmia in patients with implantable cardioverter-defibrillator and non-ischemic systolic heart failure [J].
Jedrzejczyk-Patej, Ewa ;
Mazurek, Michal ;
Lazar, Monika ;
Pruszkowska-Skrzep, Patrycja ;
Sokal, Adam ;
Kowalczyk, Jacek ;
Kowalski, Oskar ;
Kalarus, Zbigniew ;
Lenarczyk, Radoslaw .
KARDIOLOGIA POLSKA, 2023, 81 (10) :998-1005
[24]   Left ventricular sphericity independently predicts appropriate implantable cardioverter-defibrillator therapy [J].
Levine, Yehoshua C. ;
Matos, Jason ;
Rosenberg, Michael A. ;
Manning, Warren J. ;
Josephson, Mark E. ;
Buxton, Alfred E. .
HEART RHYTHM, 2016, 13 (02) :490-497
[25]   Comparison and predictors of implantable cardioverter-defibrillator therapy for primary and secondary prevention [J].
Reinder Evertz ;
Tessa van der Heijden ;
Rypko Beukema ;
Sjoerd Westra ;
Esther Meindersma ;
Caroline van Deursen ;
Kevin Vernooy .
Netherlands Heart Journal, 2023, 31 :348-356
[26]   Incidence of appropriate implantable cardioverter-defibrillator therapy and mortality after implantable cardioverter-defibrillator generator replacement: results from a real-world nationwide cohort [J].
Ruwald, Martin H. ;
Ruwald, Anne-Christine ;
Johansen, Jens Brock ;
Gislason, Gunnar ;
Nielsen, Jens Cosedis ;
Philbert, Berit ;
Riahi, Sam ;
Vinther, Michael ;
Lindhardt, Tommi B. .
EUROPACE, 2019, 21 (08) :1211-1219
[27]   Comparison and predictors of implantable cardioverter-defibrillator therapy for primary and secondary prevention [J].
Evertz, Reinder ;
van der Heijden, Tessa ;
Beukema, Rypko ;
Westra, Sjoerd ;
Meindersma, Esther ;
van Deursen, Caroline ;
Vernooy, Kevin .
NETHERLANDS HEART JOURNAL, 2023, 31 (09) :348-356
[28]   FAILURE OF AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR TO REDETECT VENTRICULAR-FIBRILLATION IN PATIENTS WITH A NONTHORACOTOMY LEAD SYSTEM [J].
JUNG, W ;
MANZ, M ;
MOOSDORF, R ;
LUDERITZ, B .
CIRCULATION, 1992, 86 (04) :1217-1222
[29]   Patients with Pacemaker or Implantable Cardioverter-Defibrillator [J].
Schulman, Peter M. ;
Rozner, Marc A. ;
Sera, Valerie ;
Stecker, Eric C. .
MEDICAL CLINICS OF NORTH AMERICA, 2013, 97 (06) :1051-+
[30]   Incidence of Appropriate Shock in Implantable Cardioverter-Defibrillator Patients With Improved Ejection Fraction [J].
Naksuk, Niyada ;
Saab, Ali ;
Li, Jian-Ming ;
Florea, Viorel ;
Akkaya, Mehmet ;
Anand, Inder S. ;
Benditt, David G. ;
Adabag, Selcuk .
JOURNAL OF CARDIAC FAILURE, 2013, 19 (06) :426-430