Ultrasound-stimulated peripheral nerve regeneration within asymmetrically porous PLGA/Pluronic F127 nerve guide conduit

被引:47
作者
Park, Sang Chul [1 ]
Oh, Se Heang [1 ]
Seo, Tae Beom [2 ]
Namgung, Uk [2 ]
Kim, Jin Man [3 ]
Lee, Jin Ho [1 ]
机构
[1] Hannam Univ, Dept Adv Mat, Taejon 305811, South Korea
[2] Daejeon Univ, Dept Oriental Med, Taejon 300716, South Korea
[3] Chungnam Natl Univ, Sch Med, Canc Res Inst, Dept Pathol, Taejon 301131, South Korea
基金
新加坡国家研究基金会;
关键词
peripheral nerve regeneration; asymmetrically porous tube; nerve guide conduit (NGC); ultrasound; PLGA/Pluronic F127; LOW-INTENSITY ULTRASOUND; SCHWANN-CELLS; THERAPEUTIC ULTRASOUND; SCIATIC-NERVE; CHANNELS; REPAIR;
D O I
10.1002/jbm.b.31659
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, we developed a novel method to fabricate a nerve guide conduit (NGC) with asymmetrical pore structure and hydrophilicity using poly(lactic-co-glycolic acid) (PLGA) and Pluronic F127 by a modified immersion precipitation method. From the animal study using a rat model (sciatic nerve defect of rat), we recognized that the unique PLGA/Pluronic F127 tube provided good environments for nerve regeneration. In this study, we applied low-intensity pulsed ultrasound as a simple and noninvasive stimulus at the PLGA/F127 NGC-implanted site transcutaneously in rats to investigate the feasibility of ultrasound for the enhanced nerve regeneration through the tube. The nerve regeneration behaviors within the ultrasound-stimulated PLGA/Pluronic F127 NGCs were compared with the NGCs without the ultrasound treatment as well as normal nerve by histological and immunohistochemical observations. It was observed that the PLGA/Pluronic F127 tube-implanted group applied with the ultrasound had more rapid nerve regeneration behavior (similar to 0.71 mm/day) than the tube-implanted group without the ultrasound treatment (similar to 0.48 mm/day). The ultrasound-treated tube group also showed greater neural tissue area as well as larger axon diameter and thicker myelin sheath than the tube group without the ultrasound treatment, indicating better nerve regeneration. The better nerve regeneration behavior in the our NGC/ultrasound system may be caused by the synergistic effect of the asymmetrically porous PLGA/Pluronic F127 tube with unique properties (selective permeability, hydrophilicity, and structural stability, which can provide good environment for nerve regeneration) and physical stimulus (stimulation of the Schwann cells and activation of the neurotrophic factors). (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 94B: 359-366, 2010.
引用
收藏
页码:359 / 366
页数:8
相关论文
共 39 条