Static and dynamic analysis of sulfamethoxazole using GO/ZnO modified glassy carbon electrode by differential pulse voltammetry and amperometry techniques

被引:18
作者
Kumar, P. Senthil [1 ,2 ]
Sreeja, B. S. [2 ,3 ]
Kumar, K. Krishna [1 ,2 ]
Padmalaya, G. [1 ,2 ]
机构
[1] Sri Sivasubramaniya Nadar Coll Engn, Dept Chem Engn, Chennai 603110, Tamil Nadu, India
[2] Sri Sivasubramaniya Nadar Coll Engn, Ctr Excellence Water Res CEWAR, Chennai 603110, Tamil Nadu, India
[3] Sri Sivasubramaniya Nadar Coll Engn, Dept Elect & Commun Engn, Chennai 603110, Tamil Nadu, India
关键词
Sulfamethoxazole; Graphene oxide; Zinc oxide; Cyclic voltammetry; Differential pulse voltammetry; Electrochemical sensor; ZNO NANOPARTICLES; OXIDE; NANOCOMPOSITE;
D O I
10.1016/j.chemosphere.2022.134926
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Surface water contamination of sulfamethoxazole (SMX) has tremendously affected the ecosystem. A primary study was performed to develop an electrochemical sensor for the determination of SMX. Overcoming the demerit associated with the conventional techniques, an electrochemical method was developed using GO/ZnO nanocomposite modified electrode to detect SMX in 0.1 M phosphate buffer (pH-5.5) buffer solution. The GO, ZnO and GO/ZnO nanocomposite were prepared using modified Hummer's, precipitation and sonochemical methods, respectively. Physico-chemical properties of all the materials and its modified electrode were analysed. Comparison was made by studying the SMX sensing performance of electrodes modified with GO, ZnO and GO/ ZnO nanocomposites. Out of which GO/ZnO nanocomposite exhibited excellent sensing performance with the concentration range from 0.10 x 10-6 to 1.5 x 10-6 M with the limit of detection (LOD) 28.9 nM. The parameters such as electrolyte, effect of pH, scan rate were optimized for effective sensing performance. From the optimized results 0.1 M phosphate buffer was found to be a suitable electrolyte and the pH 5.5 was found to be appropriate to sense SMX at the scan rate 50 mVs- 1. Under optimized condition, the Differential Pulse Voltammetry (DPV) and Amperometry techniques were adopted for electrochemical sensing of SMX under static and hydrodynamic condition. The developed method was successfully tested for real time analysis for the samples collected from waste water treatment plant.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Electrochemical study of zolpidem at glassy carbon electrode and its determination in a tablet dosage form by differential pulse voltammetry
    Radi, AE
    Bekhiet, G
    Wahdan, T
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2004, 52 (09) : 1063 - 1065
  • [42] Nafion/Multiwalled Carbon Nanotubes/Mesoporous Silica Composite Modified Glassy Carbon Electrode for the Simultaneous Electrochemical Determination of Indigo Carmine and Carbendazim by Differential Pulse Voltammetry
    Fogang, Sengor Gabou
    Deffo, Gullit
    Guenang, Leopoldine Sonfack
    Temgoua, Ranil Clement Tonleu
    Njanja, Evangeline
    Tonle, Ignas Kenfack
    Bhaumik, Asim
    Ngameni, Emmanuel
    ANALYTICAL LETTERS, 2024, 57 (08) : 1241 - 1256
  • [43] A glassy carbon electrode modified with carboxylated diamond nanoparticles for differential pulse voltammetric simultaneous determination of guanine and adenine
    Biuck Habibi
    Mojtaba Jahanbakhshi
    Microchimica Acta, 2016, 183 : 2317 - 2325
  • [44] Differential pulse adsorptive stripping voltammetric determination of methotrexate using a functionalized carbon nanotubes-modified glassy carbon electrode
    Oliveira, Geiser G.
    Janegitz, Bruno C.
    Zucolotto, Valtencir
    Fatibello-Filho, Orlando
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2013, 11 (11): : 1837 - 1843
  • [45] Determination of Silver(I) by Differential Pulse Voltammetry Using a Glassy Carbon Electrode Modified with Synthesized N-(2-Aminoethyl)-4,4′-Bipyridine
    Radulescu, Maria-Cristina
    Chira, Ana
    Radulescu, Medeea
    Bucur, Bogdan
    Bucur, Madalina Petruta
    Radu, Gabriel Lucian
    SENSORS, 2010, 10 (12): : 11340 - 11351
  • [46] Determination of Trace Tl(I) by Differential Pulse Anodic Stripping Voltammetry Using a Novel Modified Carbon Paste Electrode
    Ghanei-Motlagh, Masoud
    Baghayeri, Mehdi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (06)
  • [47] A selective analysis of sulfamethoxazole-Trimethoprim in tablet formulations using graphene oxide-zinc oxide quantum dots based nanocomposite modified glassy carbon electrode
    Kumar, P. Senthil
    Padmalaya, G.
    Elavarasan, N.
    Sreeja, B. S.
    CHEMOSPHERE, 2023, 332
  • [48] Sulfamethoxazole Detection in Milk Using a Carbon-Based Printed Electrode: Enhanced Selectivity and Response Stability by Pulse-Amperometry
    Boane, Anastacio A.
    Araujo, Diele A. G.
    Munoz, Rodrigo A. A.
    Paixao, Thiago R. L. C.
    Richter, Eduardo M.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (02)
  • [49] A selective analysis of sulfamethoxazole-Trimethoprim in tablet formulations using graphene oxide-zinc oxide quantum dots based nanocomposite modified glassy carbon electrode
    Kumar, P. Senthil
    Padmalaya, G.
    Elavarasan, N.
    Sreeja, B. S.
    CHEMOSPHERE, 2023, 332
  • [50] Impedance and voltammetry detection of bromate in food samples using NiPcMWCNTs modified glassy carbon electrode
    Balogun, Sheriff Aweda
    Fayemi, Omolola Esther
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2023, 14 (01)