Static and dynamic analysis of sulfamethoxazole using GO/ZnO modified glassy carbon electrode by differential pulse voltammetry and amperometry techniques

被引:18
|
作者
Kumar, P. Senthil [1 ,2 ]
Sreeja, B. S. [2 ,3 ]
Kumar, K. Krishna [1 ,2 ]
Padmalaya, G. [1 ,2 ]
机构
[1] Sri Sivasubramaniya Nadar Coll Engn, Dept Chem Engn, Chennai 603110, Tamil Nadu, India
[2] Sri Sivasubramaniya Nadar Coll Engn, Ctr Excellence Water Res CEWAR, Chennai 603110, Tamil Nadu, India
[3] Sri Sivasubramaniya Nadar Coll Engn, Dept Elect & Commun Engn, Chennai 603110, Tamil Nadu, India
关键词
Sulfamethoxazole; Graphene oxide; Zinc oxide; Cyclic voltammetry; Differential pulse voltammetry; Electrochemical sensor; ZNO NANOPARTICLES; OXIDE; NANOCOMPOSITE;
D O I
10.1016/j.chemosphere.2022.134926
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Surface water contamination of sulfamethoxazole (SMX) has tremendously affected the ecosystem. A primary study was performed to develop an electrochemical sensor for the determination of SMX. Overcoming the demerit associated with the conventional techniques, an electrochemical method was developed using GO/ZnO nanocomposite modified electrode to detect SMX in 0.1 M phosphate buffer (pH-5.5) buffer solution. The GO, ZnO and GO/ZnO nanocomposite were prepared using modified Hummer's, precipitation and sonochemical methods, respectively. Physico-chemical properties of all the materials and its modified electrode were analysed. Comparison was made by studying the SMX sensing performance of electrodes modified with GO, ZnO and GO/ ZnO nanocomposites. Out of which GO/ZnO nanocomposite exhibited excellent sensing performance with the concentration range from 0.10 x 10-6 to 1.5 x 10-6 M with the limit of detection (LOD) 28.9 nM. The parameters such as electrolyte, effect of pH, scan rate were optimized for effective sensing performance. From the optimized results 0.1 M phosphate buffer was found to be a suitable electrolyte and the pH 5.5 was found to be appropriate to sense SMX at the scan rate 50 mVs- 1. Under optimized condition, the Differential Pulse Voltammetry (DPV) and Amperometry techniques were adopted for electrochemical sensing of SMX under static and hydrodynamic condition. The developed method was successfully tested for real time analysis for the samples collected from waste water treatment plant.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Sensitive detection of uranium in water samples using differential pulse adsorptive stripping voltammetry on glassy carbon electrode
    Zhou, Zhiping
    Zhou, Yueming
    Liang, Xizhen
    Xie, Fang
    Liu, Shujuan
    Ma, Jianguo
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 322 (03) : 2049 - 2056
  • [22] A glassy carbon electrode modified with carboxylated diamond nanoparticles for differential pulse voltammetric simultaneous determination of guanine and adenine
    Habibi, Biuck
    Jahanbakhshi, Mojtaba
    MICROCHIMICA ACTA, 2016, 183 (07) : 2317 - 2325
  • [23] DETERMINATION OF DRIMARENE BLUE X-BLN AT A GLASSY CARBON ELECTRODE BY DIFFERENTIAL PULSE VOLTAMMETRY
    Radi, Abd-Elgawad M.
    Mostafa, Mohammed R.
    Elshafey, Reda M.
    Hegazy, Talaat A.
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2011, 76 (12) : 1765 - 1773
  • [24] Differential pulse voltammetric assay for the carcinoembryonic antigen using a glassy carbon electrode modified with layered molybdenum selenide, graphene, and gold nanoparticles
    He, Baoshan
    MICROCHIMICA ACTA, 2017, 184 (01) : 229 - 235
  • [25] Direct Determination of Trace Dopamine in an Ascorbic Acid Solution at a Bare Glassy Carbon Electrode Using Differential Pulse Voltammetry
    Sun, Lijian
    Chen, Jing
    Zhao, Fangmin
    Liu, Na
    Zhang, Yingqiu
    Jia, Jianbo
    Wang, Jianguo
    ELECTROANALYSIS, 2015, 27 (06) : 1411 - 1415
  • [26] Simultaneous determination of ascorbic acid, epinephrine, and uric acid by differential pulse voltammetry using poly(p-xylenolsulfonephthalein) modified glassy carbon electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, T.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 79 (02) : 480 - 487
  • [27] SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF p-AMINOPHENOL AND PARACETAMOL USING ACTIVATED GLASSY CARBON ELECTRODE: CYCLIC VOLTAMMETRY AND DIFFERENTIAL PULSE VOLTAMMETRY STUDY
    Tikuye, Teklu
    Feyisa, Tilahun Yai
    Kitte, Shimeles Addisu
    Gebretsadik, Gebru
    Yenealem, Dereje
    ACTA CHEMICA IASI, 2020, 28 (02) : 146 - 162
  • [28] Differential pulse voltammetric determination of hexavalent chromium using nickel hexacyanoferrate modified glassy carbon electrode
    Dinbore, Wendimagegn T.
    Dabbo, Wolde C.
    Washe, Aemayehu P.
    SUSTAINABLE ENVIRONMENT, 2021, 7 (01):
  • [29] Highly selective determination of ascorbic acid, dopamine, and uric acid by differential pulse voltammetry using poly(sulfonazo III) modified glassy carbon electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, T.
    Arabzadeh, A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 147 (01): : 213 - 221
  • [30] Simultaneous determination of amlodipine and losartan using an iron metal-organic framework/mesoporous carbon nanocomposite-modified glassy carbon electrode by differential pulse voltammetry
    Rajpurohit, Anuja S.
    Bora, Dimple K.
    Srivastava, Ashwini K.
    ANALYTICAL METHODS, 2018, 10 (45) : 5423 - 5438