Static and dynamic analysis of sulfamethoxazole using GO/ZnO modified glassy carbon electrode by differential pulse voltammetry and amperometry techniques

被引:18
|
作者
Kumar, P. Senthil [1 ,2 ]
Sreeja, B. S. [2 ,3 ]
Kumar, K. Krishna [1 ,2 ]
Padmalaya, G. [1 ,2 ]
机构
[1] Sri Sivasubramaniya Nadar Coll Engn, Dept Chem Engn, Chennai 603110, Tamil Nadu, India
[2] Sri Sivasubramaniya Nadar Coll Engn, Ctr Excellence Water Res CEWAR, Chennai 603110, Tamil Nadu, India
[3] Sri Sivasubramaniya Nadar Coll Engn, Dept Elect & Commun Engn, Chennai 603110, Tamil Nadu, India
关键词
Sulfamethoxazole; Graphene oxide; Zinc oxide; Cyclic voltammetry; Differential pulse voltammetry; Electrochemical sensor; ZNO NANOPARTICLES; OXIDE; NANOCOMPOSITE;
D O I
10.1016/j.chemosphere.2022.134926
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Surface water contamination of sulfamethoxazole (SMX) has tremendously affected the ecosystem. A primary study was performed to develop an electrochemical sensor for the determination of SMX. Overcoming the demerit associated with the conventional techniques, an electrochemical method was developed using GO/ZnO nanocomposite modified electrode to detect SMX in 0.1 M phosphate buffer (pH-5.5) buffer solution. The GO, ZnO and GO/ZnO nanocomposite were prepared using modified Hummer's, precipitation and sonochemical methods, respectively. Physico-chemical properties of all the materials and its modified electrode were analysed. Comparison was made by studying the SMX sensing performance of electrodes modified with GO, ZnO and GO/ ZnO nanocomposites. Out of which GO/ZnO nanocomposite exhibited excellent sensing performance with the concentration range from 0.10 x 10-6 to 1.5 x 10-6 M with the limit of detection (LOD) 28.9 nM. The parameters such as electrolyte, effect of pH, scan rate were optimized for effective sensing performance. From the optimized results 0.1 M phosphate buffer was found to be a suitable electrolyte and the pH 5.5 was found to be appropriate to sense SMX at the scan rate 50 mVs- 1. Under optimized condition, the Differential Pulse Voltammetry (DPV) and Amperometry techniques were adopted for electrochemical sensing of SMX under static and hydrodynamic condition. The developed method was successfully tested for real time analysis for the samples collected from waste water treatment plant.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Determination of Folic Acid in Food by Differential Pulse Voltammetry with ZnO@GO Nanocomposites Modified Glassy Carbon Electrode
    Ma, Jing Xi
    Yang, Liu
    Wang, Lei
    Wu, Shu Qing
    Liu, Yan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (01): : 1 - 12
  • [2] Electrochemical Investigation of Thiophene on Glassy Carbon Electrode and Quantitative Determination of it in Simulated Oil Solution by Differential Pulse Voltammetry and Amperometry Techniques
    Mostafavi, S. Mojtaba
    Rouhollahi, Ahmad
    Adibi, Mina
    Mohajeri, Ali
    Pashaee, Farshid
    Pyriaee, Masoumeh
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (12) : 5356 - 5360
  • [3] Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole
    Madakbas, Seyfullah
    Kamiloglu, Senem
    Yetimoglu, Ece Kok
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (06) : 725 - 730
  • [4] Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole
    Seyfullah Madakbaş
    Senem Kamiloǧlu
    Ece Kök Yetimoǧlu
    Journal of Analytical Chemistry, 2015, 70 : 725 - 730
  • [5] Determination of the herbicide paraquat using the new Ag-GO/CuO/GCE-modified glassy carbon electrode by differential pulse voltammetry
    Savary, Abdolrahman
    Yari, Abdollah
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2021, 68 (10) : 1987 - 1997
  • [6] Differential pulse voltammetry determination of salbutamol using disulfite tungsten/activated carbon modified glassy carbon electrode
    Do Mai Nguyen
    Thanh Tam Toan Tran
    Manh Dung Doan
    Van Thuan Le
    Quang Khieu Dinh
    CHEMOSPHERE, 2022, 303
  • [7] Electrochemical determination of nonylphenol using differential pulse voltammetry based on a graphene-DNA-modified glassy carbon electrode
    Zeng, Lixuan
    Zhang, Aizhen
    Zhu, Xiaohua
    Zhang, Chuyi
    Liang, Yong
    Nan, Junmin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 703 : 153 - 157
  • [9] Determination of trimebutine in pharmaceuticals by differential pulse voltammetry at a glassy carbon electrode
    Adhoum, N
    Monser, L
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (04) : 619 - 623
  • [10] Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode
    Manh, Tran Duc
    Nguyen, Vo Thang
    Duyen, Vu Thi
    Nga, Nguyen Thi Thy
    Man, Nguyen Quang
    Thoa, Pham Thi Huyen
    Trinh, Le Huu
    Khieu, Dinh Quang
    JOURNAL OF NANOPARTICLE RESEARCH, 2023, 25 (09)