Pulsatility index variations using two different transit-time flowmeters in coronary artery bypass surgery

被引:18
|
作者
Nordgaard, Havard B. [1 ]
Vitale, Nicola [2 ]
Astudillo, Rafael [2 ]
Renzulli, Attilio [4 ]
Romundstad, Pal [3 ]
Haaverstad, Rune [1 ,5 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7489 Trondheim, Norway
[2] St Olavs Univ Hosp, Dept Cardiothorac Surg, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Publ Hlth, N-7489 Trondheim, Norway
[4] Univ Magna Grecia, Dept Cardiac Surg, Catanzaro, Italy
[5] Univ Bergen, Dept Surg Sci, Bergen, Norway
关键词
CABG; Coronary graft assessment; Flowmetry; Pulsatile index; PI; Transit-time; FLOW MEASUREMENT; OFF-PUMP; BLOOD-FLOW; VALIDATION; PATENCY;
D O I
10.1016/j.ejcts.2009.11.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transit-time flow measurement is widely accepted as an intra-operative assessment in coronary artery bypass grafting (CABG). However, the two most commonly applied flowmeters, manufactured by MediStim ASA and Transonic Inc., have different default filter settings of 20 and 10 Hz, respectively. This may cause different flow measurements, which will influence the reported results. The aim was to compare pulsatility index (PI) values recorded by the MediStim and Transonic flowmeters in two different clinical settings: (1) analysis of the flow patterns recorded simultaneously by both flowmeters in the same CABGs; and (2) evaluation of flow patterns under different levels of filter settings in the same grafts. Methods: Graft flow and PI were measured using the two different flowmeters simultaneously in 19 bypass grafts. Finally, eight grafts were assessed under different digital filter settings at 5, 10, 20, 30, 50 and 100 Hz. Results: The Transonic flowmeter provided substantially lower PI as compared with the MediStim flowmeter. By increasing the filter setting in the flowmeter, PI increased considerably. Conclusions: The MediStim flowmeter displayed a lower PI than the Transonic, due to a lower filter setting. In the Transonic, flow signals are filtered at a lower level, rendering a 'smoother' pattern of flow curves. Because different filter settings determine different PIs, caution must be taken when flow values and flowmeters are compared. The type of flowmeter should be indicated whenever graft flow measurements and derived indexes are provided. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1063 / 1067
页数:5
相关论文
共 50 条
  • [41] Evaluating hemodynamic outcomes of different dosages of intravenous nitroglycerin after coronary artery bypass graft surgery
    Masoumi, Gholamreza
    Hidarpour, Evaz
    Tabae, Ali Sadeghpour
    Ziayeefard, Mohsen
    Azarasa, Atosa
    Abneshahidi, Amin
    Anbardan, Sanam Javid
    Kashefi, Parviz
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2011, 16 (07): : 910 - 915
  • [42] Effect of Different Pump Heads for CPB on Early Cognitive Outcome after Coronary Artery Bypass Surgery
    Holinski, Sebastian
    Claus, Benjamin
    Haeger, Nicole
    Neumann, Konrad
    Uebelhack, Ralf
    Konertz, Wolfgang
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 19 (04) : 273 - 278
  • [43] Effects of sex, body mass index, and body size on the outcome of coronary artery bypass surgery: Iranian experience
    Nemati M.H.
    Astaneh B.
    General Thoracic and Cardiovascular Surgery, 2010, 58 (9) : 452 - 455
  • [44] Impact of Aortic Cross Clamp Time on Postoperative Inotropic Support in Coronary Artery Bypass Grafting Surgery
    Paracha, Vaqar Ilahi
    Ahmad, Anas
    Chaudhry, Imtiaz Ahmed
    Naseer, Mehwish
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (02): : 395 - 398
  • [45] Management of carotid disease in patients undergoing coronary artery bypass surgery: is it time to change our approach?
    Venkatachalam, Sridhar
    Shishehbor, Mehdi H.
    CURRENT OPINION IN CARDIOLOGY, 2011, 26 (06) : 480 - 487
  • [46] Intraoperative transit-time flowmetry in patients undergoing coronary surgery to determine relationships between graft flow and patency and prior coronary interventions and flow demand: a retrospective study
    Hiroyuki Nakajima
    Akitoshi Takazawa
    Akihiro Yoshitake
    Masato Tochii
    Chiho Tokunaga
    Jun Hayashi
    Hiroaki Izumida
    Daisuke Kaneyuki
    Toshihisa Asakura
    Atsushi Iguchi
    Journal of Cardiothoracic Surgery, 13
  • [47] Intraoperative transit-time flowmetry in patients undergoing coronary surgery to determine relationships between graft flow and patency and prior coronary interventions and flow demand: a retrospective study
    Nakajima, Hiroyuki
    Takazawa, Akitoshi
    Yoshitake, Akihiro
    Tochii, Masato
    Tokunaga, Chiho
    Hayashi, Jun
    Izumida, Hiroaki
    Kaneyuki, Daisuke
    Asakura, Toshihisa
    Iguchi, Atsushi
    JOURNAL OF CARDIOTHORACIC SURGERY, 2018, 13
  • [48] Intraoperative graft verification in coronary surgery: increased diagnostic accuracy adding high-resolution epicardial ultrasonography to transit-time flow measurement
    Di Giammarco, Gabriele
    Canosa, Carlo
    Foschi, Massimiliano
    Rabozzi, Roberto
    Marinelli, Daniele
    Masuyama, Shinji
    Ibrahim, Bedir M.
    Ranalletta, Remo Antonio
    Penco, Maria
    Di Mauro, Michele
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 45 (03) : E41 - E45
  • [49] A Frailty Index to Predict Mortality, Resource Utilization and Costs in Patients Undergoing Coronary Artery Bypass Graft Surgery in Ontario
    Johnson, Ana
    Hore, Elizabeth
    Milne, Brian
    Muscedere, John
    Peng, Yingwei
    McIsaac, Daniel I.
    Parlow, Joel
    CJC OPEN, 2024, 6 (02) : 72 - 81
  • [50] Effect of dopexamine hydrochloride on renal vascular resistance index and haemodynamic responses following coronary artery bypass graft surgery
    Sherry, E
    Tooley, MA
    Bolsin, SN
    Monk, CR
    Willcox, J
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1997, 14 (02) : 184 - 189