Pulsatility index variations using two different transit-time flowmeters in coronary artery bypass surgery

被引:18
|
作者
Nordgaard, Havard B. [1 ]
Vitale, Nicola [2 ]
Astudillo, Rafael [2 ]
Renzulli, Attilio [4 ]
Romundstad, Pal [3 ]
Haaverstad, Rune [1 ,5 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7489 Trondheim, Norway
[2] St Olavs Univ Hosp, Dept Cardiothorac Surg, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Publ Hlth, N-7489 Trondheim, Norway
[4] Univ Magna Grecia, Dept Cardiac Surg, Catanzaro, Italy
[5] Univ Bergen, Dept Surg Sci, Bergen, Norway
关键词
CABG; Coronary graft assessment; Flowmetry; Pulsatile index; PI; Transit-time; FLOW MEASUREMENT; OFF-PUMP; BLOOD-FLOW; VALIDATION; PATENCY;
D O I
10.1016/j.ejcts.2009.11.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transit-time flow measurement is widely accepted as an intra-operative assessment in coronary artery bypass grafting (CABG). However, the two most commonly applied flowmeters, manufactured by MediStim ASA and Transonic Inc., have different default filter settings of 20 and 10 Hz, respectively. This may cause different flow measurements, which will influence the reported results. The aim was to compare pulsatility index (PI) values recorded by the MediStim and Transonic flowmeters in two different clinical settings: (1) analysis of the flow patterns recorded simultaneously by both flowmeters in the same CABGs; and (2) evaluation of flow patterns under different levels of filter settings in the same grafts. Methods: Graft flow and PI were measured using the two different flowmeters simultaneously in 19 bypass grafts. Finally, eight grafts were assessed under different digital filter settings at 5, 10, 20, 30, 50 and 100 Hz. Results: The Transonic flowmeter provided substantially lower PI as compared with the MediStim flowmeter. By increasing the filter setting in the flowmeter, PI increased considerably. Conclusions: The MediStim flowmeter displayed a lower PI than the Transonic, due to a lower filter setting. In the Transonic, flow signals are filtered at a lower level, rendering a 'smoother' pattern of flow curves. Because different filter settings determine different PIs, caution must be taken when flow values and flowmeters are compared. The type of flowmeter should be indicated whenever graft flow measurements and derived indexes are provided. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1063 / 1067
页数:5
相关论文
共 50 条
  • [31] Conduit selection and early graft failure in coronary artery bypass surgery: A post hoc analysis of the Cardiovascular Outcomes for People Using Anticoagulation Strategies (COMPASS) coronary artery bypass grafting study
    Alboom, Mariam
    Browne, Austin
    Sheth, Tej
    Zheng, Zhe
    Dagenais, Francois
    Noiseux, Nicolas
    Brtko, Miroslav
    Stevens, Louis-Mathieu
    Lee, Shun Fu
    Copland, Ingrid
    Power, Patricia
    Eikelboom, John
    Lamy, Andre
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 165 (03): : 1080 - +
  • [32] Coronary bypass surgery using the internal thoracic artery after reconstruction of occluded subclavian artery.
    Ochi M.
    Fujii M.
    Saji Y.
    Ogasawara H.
    Ishii Y.
    Tanaka S.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2000, 48 (8): : 524 - 527
  • [33] Coronary Artery Bypass Graft Surgery Using the Radial Artery as a Secondary Conduit Improves Patient Survival
    Lin, John
    Cheng, Wen
    Czer, Lawrence S.
    De Robertis, Michele A.
    Mirocha, James
    Ruzza, Andrea
    Kass, Robert M.
    Khoynezhad, Ali
    Ramzy, Danny
    Esmailian, Fardad
    Trento, Alfredo
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2013, 2 (04):
  • [34] Using the cardiac depression scale in men recovering from coronary artery bypass surgery
    King, Kathryn M.
    Colella, Tracey J. F.
    Faris, Peter
    Thompson, David R.
    JOURNAL OF CLINICAL NURSING, 2009, 18 (11) : 1617 - 1624
  • [35] Elective Coronary Artery Bypass Graft Surgery Using Reduced Homologous Blood Transfusion
    Jannati, Mansour
    GAZI MEDICAL JOURNAL, 2022, 33 (03): : 306 - 311
  • [36] Patient anatomy predicts operative time in robotic totally endoscopic coronary artery bypass surgery
    Wehman, Brody
    Lehr, Eric J.
    Lahiji, Kian
    Lee, Jeffry D.
    Kon, Zachary N.
    Jeudy, Jean
    Griffith, Bartley P.
    Bonatti, Johannes
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 19 (04) : 572 - 576
  • [37] Mediterranean dietary quality index and dietary phytochemical index among patients candidate for coronary artery bypass grafting (CABG) surgery
    Mahdieh Abbasalizad Farhangi
    Mahdi Najafi
    Mohammad Asghari Jafarabadi
    Leila Jahangiry
    BMC Cardiovascular Disorders, 17
  • [38] Mediterranean dietary quality index and dietary phytochemical index among patients candidate for coronary artery bypass grafting (CABG) surgery
    Farhangi, Mahdieh Abbasalizad
    Najafi, Mahdi
    Jafarabadi, Mohammad Asghari
    Jahangiry, Leila
    BMC CARDIOVASCULAR DISORDERS, 2017, 17
  • [39] The relationship between epicardial fat tissue thickness and transit time flow measurement values of coronary artery bypass grafts
    Ucak, Haci Ali
    JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 2020, 12 (04) : 307 - 312
  • [40] Predictiveness of different preoperative risk assessments for postoperative bleeding after coronary artery bypass grafting surgery
    Gunertem, Eren
    Urcun, Salim
    Pala, Arda Aybars
    Budak, Ali Baran
    Ercisli, Murat Abdulhamid
    Gunaydin, Serdar
    PERFUSION-UK, 2021, 36 (03): : 277 - 284